Browse
Search
2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2024
>
2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2024 1:56:17 PM
Creation date
7/30/2024 1:54:37 PM
Metadata
Fields
Template:
Contract
Date
7/10/2024
Contract Starting Date
7/10/2024
Contract Ending Date
7/15/2024
Contract Document Type
Contract
Amount
$146,290.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County West Campus Office Building -HVAC <br />PDC Project 23020 In-Row Computer Room Air Conditioners 23 81 24.01 - 2 <br />A.A field-adjustable,modular,supply-air baffle system shall be located in the discharge air stream on <br />the front of the cabinet to direct air toward the equipment racks and balance air-flow requirements <br />within the row.The five modular baffle segments shall be easily reconfigurable to redirect air flow <br />as cooling requirements change.Controlling the air flow prevents hot spots and maintains high <br />return-air temperatures by not blowing cold air over racks or out the ends of aisles.By focusing the <br />cold air where it is needed and meeting the servers'requirements,the need for excessive airflow <br />and energy consumption is eliminated. <br />2.05 CABINET CONSTRUCTION AND ACCESSIBILITY <br />A.Cabinet Construction <br />1.The exterior panels of the unit shall be 20=gauge steel and powder-coated with charcoal <br />color paint to protect against corrosion and follow Knürr rack appearance guidelines to mirror <br />the style of neighboring equipment racks.The cabinet shall be mounted on casters for quick <br />installation and provided with leveling feet.Both doors shall have a powder-coated sheet- <br />metal frame with hexagonal perforations leaving 81%of the door open to air flow for efficient <br />cooling.The front and rear doors shall swing 170 degrees open,shall be removable,and <br />shall feature a two-point latch.The powder-coat painted steel side panels shall be lined with <br />half-inch closed-cell polymeric insulation and secured using quarter-turn fasteners. <br />B.Serviceability <br />1.The cabinet shall be designed so all components are easily accessible for service and <br />maintenance through either the front or rear of the unit.Units that are not fully accessible <br />from front and rear or not serviceable in place shall be unacceptable. <br />2.Side access shall not be required.Each of the variable-speed fans shall be individually <br />replaceable through the front door of the unit.Units with a compressor and/or a condensate <br />pump shall be conveniently mounted near the edge of the unit. <br />C.Supply Air Baffle System <br />1.A field-adjustable,modular,supply-air baffle system shall be located in the discharge air <br />stream on the front of the cabinet to direct air toward the server racks and balance air-flow <br />requirements within the row.The five modular baffle segments shall be easily reconfigurable <br />to redirect airflow as cooling requirements change.Controlling the air flow prevents hot spots <br />and maintains high return-air temperatures by not blowing cold air over racks or out the ends <br />of aisles.By focusing the cold air where it is needed and meeting the rack equipment’s <br />cooling requirements,the need for excessive air flow and energy consumption is eliminated. <br />2.06 LOCKING DISCONNECT SWITCH <br />A.A manual disconnect switch shall be mounted in the electrical panel and be capable of disrupting <br />the flow of power to the unit.The electric-panel compartment shall be accessible only with the <br />switch in the Off position.It shall be located behind the rear door for quick access. <br />2.07 SHORT CIRCUIT CURRENT RATING (SCCR) <br />A.The electrical panel shall provide at least 65,000A SCCR. <br />2.08 FILTRATION <br />A.MERV 8 <br />1.The two filters shall be an integral part of the system,located within the cabinet and <br />serviceable from the rear.The filters shall be washable,half-inch thick with an ASHRAE 52.2 <br />MERV8 rating.A filter clog alarm shall be included. <br />B.Extra Filter Set (Optional) <br />1.2 extra set(s)of filters shall be provided per system. <br />2.09 HEAT REJECTION <br />A.Standard Features <br />1.The condenser shall consist of microchannel condenser coil(s),propeller fan(s)direct driven <br />by individual fan motor(s),electrical controls,housing,and mounting legs.The Liebert®air- <br />cooled condenser shall provide positive refrigerant head pressure control to the indoor <br />cooling unit by adjusting heat rejection capacity.Microchannel coils shall provide superior <br />Docusign Envelope ID: 8DED1454-68D2-4E36-9FC6-E56FF2124E5D
The URL can be used to link to this page
Your browser does not support the video tag.