Browse
Search
2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2024
>
2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2024 1:56:17 PM
Creation date
7/30/2024 1:54:37 PM
Metadata
Fields
Template:
Contract
Date
7/10/2024
Contract Starting Date
7/10/2024
Contract Ending Date
7/15/2024
Contract Document Type
Contract
Amount
$146,290.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County West Campus Office Building -HVAC <br />PDC Project 23020 BAS DIRECT DIGITAL CONTROL <br />SYSTEM 23 09 02 - 4 <br />2.It shall be possible to use any system measured point data or status,any system calculated <br />data,a result from any process,or any user-defined constant in any controller in the system. <br />3.Any process shall be able to issue commands to points in any and all other controllers in the <br />system. <br />4.Processes shall be able to generate operator messages and advisories to other operator I/O <br />devices. A process shall be able to directly send a message to a specified device or cause <br />the execution of a dial-up connection to a remote device such as a printer or pager. <br />5.Each controller shall support plain language text comment lines in the operating program to <br />allow for quick troubleshooting,documentation,and historical summaries of program <br />development. <br />6.Controller shall provide a HELP function key,providing enhanced context sensitive on-line <br />help with task oriented information from the user manual. <br />2.04 BUILDING CONTROLLERS <br />A.Building Controllers shall be 32 bit,multi-tasking,multi-user,real-time 48 MHz digital control <br />processors consisting of modular hardware with plug-in enclosed processors,communication <br />controllers,power supplies and input/output point modules. Controller size shall be sufficient to <br />fully meet the requirements of this specification and the attached point list. <br />B.Each Building Controller shall support a minimum of 3 directly connected Secondary Networks. <br />C.Each Building Controller shall support firmware upgrades without the need to change hardware. <br />D.Spare Point Capacity. <br />1.Each Building Controller shall have a minimum of 10 percent spare point capacity. <br />2.The type of spares shall be in the same proportion as the implemented I/O functions of the <br />panel,but in no case shall there be less than one spare of each implemented I/O type. <br />3.Provide all processors,power supplies,and communication controllers so that the <br />implementation of adding a point to the spare point location only requires the addition of the <br />appropriate: <br />a.Expansion modules <br />b.Sensor/actuator <br />c.Field wiring/tubing. <br />2.05 APPLICATION SPECIFIC CONTROLLERS (ASC) <br />A.General <br />1.Each Building Controller shall be able to communicate with application specific controllers <br />(ASCs)over the Secondary Network to control terminal equipment only. <br />2.Each ASC shall operate as a stand-alone controller capable of performing its specified control <br />responsibilities independently of other controllers in the network.Each ASC shall be a <br />microprocessor-based,multi-tasking,real-time digital control processor. <br />3.Communication.Each controller shall perform its primary control function independent of <br />other Secondary Network communication,or if Secondary Network communication is <br />interrupted.Reversion to a fail-safe mode of operation during Secondary Network interruption <br />is not acceptable. <br />4.Control Algorithms.The controller shall receive its real-time data from the Building Controller <br />time clock to insure Secondary Network continuity. Each controller shall include algorithms <br />incorporating proportional,integral and derivative (PID)gains for all applications. All PID <br />gains and biases shall be field-adjustable by the user via room sensor LCD or the portable <br />operator’s terminal as specified herein. Controllers that incorporate proportional and integral <br />(PI)control algorithms only shall not be acceptable. <br />5.Control Applications.Operating programs shall be field-selectable for specific applications. In <br />addition,specific applications may be modified to meet the user's exact control strategy <br />requirements,allowing for additional system flexibility.Controllers that require factory <br />changes of all applications are not acceptable. <br />6.Calibration.Each controller shall include provisions for manual and automatic calibration of <br />the differential pressure transducer in order to maintain stable control and insuring against <br />drift over time. <br />Docusign Envelope ID: 8DED1454-68D2-4E36-9FC6-E56FF2124E5D
The URL can be used to link to this page
Your browser does not support the video tag.