Browse
Search
2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2024
>
2024-390-E-AMS-Brady Services-WCOB Server Room HVAC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2024 1:56:17 PM
Creation date
7/30/2024 1:54:37 PM
Metadata
Fields
Template:
Contract
Date
7/10/2024
Contract Starting Date
7/10/2024
Contract Ending Date
7/15/2024
Contract Document Type
Contract
Amount
$146,290.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County West Campus Office Building -HVAC <br />PDC Project 23020 Electrical Work 23 05 12 - 1 <br />SECTION 23 05 12 <br />ELECTRICAL WORK <br />PART 1 GENERAL <br />1.01 DIVISION OF WORK <br />A.This Contractor shall be responsible for the final electrical and the entire control connections and <br />wiring to all equipment installed as part of his contract. <br />B.Contractor shall review the electrical plans,where applicable,to establish points of connection and <br />the extent of his electrical work to be provided in his contract. <br />C.Unless otherwise noted,this Contractor shall wire from his equipment to disconnect switches, <br />junction boxes,or panelboard circuit breakers as provided by the Electrical Contractor or as <br />required by the existing conditions. <br />D.All power and control wiring shall be in conduits. Refer to electrical specifications for conduit and <br />conduit fittings. <br />E.All electrical work shall be performed by a licensed electrician. <br />F.All electrical work shall be in accordance with the State Building Code and all its supplements,the <br />latest edition of the National Electrical Code and the electrical specifications. <br />PART 2 PRODUCT <br />2.01 GENERAL REQUIREMENTS <br />A.All motor starters,disconnects,switches,relays,conduits,conductors,etc.that are required for a <br />complete electrical power and/or control system shall conform to the requirements set forth by <br />NEC. <br />B.Refer to the plans for the type,size and electrical characteristics of the starters,disconnects, <br />switches,relays,conductor and conduits. <br />C.All conductors and conduits shall be sized as noted on the plans or As required per NEC. <br />D.All individual motor starters for mechanical equipment (i.e.,fans,pumps,etc.)shall be furnished <br />and installed under Division 23. <br />E.All relays,actuators,timers,seven-day clocks,alternators,pressure,vacuum,float,flow, <br />pneumatic-electric,and electric-pneumatic switches,aquastats,freezestats,line and low voltage <br />thermostats,thermals,remote selector switches,remote push-button stations,emergency break- <br />glass stations,interlocking,disconnect switches beyond termination point,and other <br />appurtenances associated with equipment under Division 23 shall be furnished,installed and wired <br />under Division 23. <br />PART 3 EXECUTION <br />3.01 GENERAL REQUIREMENTS <br />A.All motor starters,disconnects,and switches shall be installed on or as close to the equipment <br />they are serving as possible,or where shown on the plans. <br />B.Electrical connection to equipment subject to vibration which develops objectionable noises shall <br />be made from the conduit system with short lengths of flexible "Liquid-Tite"conduit.Connection to <br />other equipment shall be made with rigid conduit. <br />C.Conduits shall be run in a concealed space such as wall cavities,ceiling cavities,etc.except in the <br />mechanical rooms where conduit may be run exposed. <br />END OF SECTION 23 05 12 23 05 12 <br />Docusign Envelope ID: 8DED1454-68D2-4E36-9FC6-E56FF2124E5D
The URL can be used to link to this page
Your browser does not support the video tag.