1 OF 2 <br />21 LIGHT REMOTE ANNUNCIATOR AND REMOTE RELAY PANEL <br />Part No. 0604160SSD <br />Rev. F 09/27/22 GENERATOR CONTROLSThe Remote Annunciator Panel provides remote monitoring <br />and annunciation of up to 18 generator parameters using LEDs <br />located on the annunciator keypad. It also provides two system <br />level warnings which are System Ready and <br />Communications OK. <br />The Relay Panel has up to 8 selectable functions on form <br />A relays; multiple relay panels can be connected for all 18 <br />generator parameters. <br />The specific faults can be selected using either the DIP switches <br />located on the annunciator circuit board or through a computer <br />via the RS232 connection on the circuit board. All relays are <br />energized on power up and open during a <br />fault condition. <br />Communication is via a RS485 serial data link and power is <br />supplied by the generator battery (+12 VDC or +24 VDC). <br />The Remote Annunciator Panel complies with NFPA 99 and <br />NFPA 110. <br />Operating Temperature .................................................................................................................................................................................-25 ºC to 60 ºC <br />Humidity ........................................................................................................................................................................................0 to 95% Non-Condensing <br />Power Supply ......................................................................................................................................................Generator Battery, +12 or +24 Volts DC <br />Power Usage .......................................................................................................................................................................................................6 WattsTypical <br />Communication Line .....................................................................................................................RS485 Fully Isolated Twisted Pair Cable with Shield <br />Maximum Cable Length ................................................................................................................................................................................................4,000 ft <br />Relay Output ...............................................................One N.O. Contact (Energized when Annunciator is Powered and No Faults are Present) <br />Relay Contact Rating ..............................................................................................................................................................................................30 VDC, 1 A <br />Enclosure Rating ............................................................................................................................................................................................................NEMA 1 <br />Alarm Horn (Remote Annunciator Panels Only) ......................................................................................................................................90 dB @ 10 cm <br />Model 0054650 Gray Remote Annunciator Panel without Relays <br />Model 0054660 Gray Remote Relay Panel without LEDs and Keypad (Relays Only) <br />Model 0054640 Gray Remote Annunciator Panel with 8 Relays <br />Model 0056370 Tan Flush Mount Enclosure without Annunciator <br />Model 0066950 Gray Flush Mount Enclosure without Annunciator <br />Description: <br />Environmental Specifications <br />Docusign Envelope ID: 2F58BEE5-DDBE-42EB-8DFA-5E2508488B04