Orange County NC Website
controls@comfortmc.com <br />(919)383-2502 <br />4008 Comfort Ln, Durham, NC 27705 <br /> <br />Page 1 of 2 <br />Mechanical Contractor License: 24751 <br />Engineering License: D-0375 <br /> <br />Date: 5/10/24 <br />To: Angel Barnes <br />Company: Orange County <br />Address: 350 College Park Rd <br /> Hillsborough, NC 27278 <br /> <br />From: Eric Puckett <br />Company: Comfort Mechanical Contractors <br />Address: 4008 Comfort Ln Durham, NC 27705 <br />Phone: 919-323-7423 <br />Email: Epuckett@comfortmc.com <br />Project: Waterstone EMS BAS System <br /> <br />• BAS Server <br />o Provide and Install: <br />▪ Honeywell Jace 8000 with Device licensing and SMA Licenses. <br />• Provide: <br />o Floor Plan and equipment Graphics, web accessible <br />o Trending <br />o Email Alarming <br />o Scheduling. <br />▪ Tosibox VPN Appliance and (1) Customer Key for access. <br />• Internet to be provided by the customer. Cellular internet can be provided by CMC if needed. Additional fees <br />apply. <br />o Control Panel to be mounted in Mech Rm 212. <br />▪ Reuse existing 120vac circuit. <br />• (3) Existing Split Systems (IDU-2.1, 2.2, 2.3) <br />o Replace Existing Thermostat: <br />▪ Honeywell BACnet MSTP Communicating Thermostat <br />▪ Supply Air Temperature Sensor <br />▪ Supply Fan Status <br />o Setup Thermostats to limit local control to +/- 4 deg offset. <br />o Provide configuration and integration to BAS. <br />o Setup Trending and Alarming <br />o Provide point to point checkout. <br />• (1) Existing A/C-2.1 <br />o Provide and install Space Temperature Sensor for Monitoring. <br />▪ Temp sensor to be tied back to one of IDU communicating thermostats. <br />o Provide programming and integration to BAS. <br />o Setup Trending and Alarming. <br />o Provide Point to Point Checkout. <br />• Controls Installation <br />o Install BACnet MSTP Communication bus to (3) IDU’s from BAS control panel. <br />o Controls components to be field installed. <br />o All low voltage cables are plenum rated. <br />o EMT only to be used where plenum rated cable is exposed. <br />o Reuse all existing low voltage cable. Provide and install new cable as needed. <br />• Control Submittals <br />o Provide Control Submittals for approval by engineers. <br />o Project the following at project turnover: <br />▪ Control Submittal As-builts <br />▪ Terminal Unit Checkout Forms <br />▪ Zone Maps <br />▪ Back-up of completed BAS System. <br />• Warranty <br />o Provide 1-year parts and labor warranty. <br />• Owner Training <br />o Provide onsite owner training. <br />• General Exclusions <br />o Overtime, Weekend, and Night Labor. <br />o Repair or replacement to existing Controls (Controllers, Sensors, Etc.) <br />o Line/Load Voltage wiring to any HVAC/Controls equipment. <br />o Dampers, VFD's, Starters unless specifically listed above. <br /> <br /> <br /> <br />DocuSign Envelope ID: 0BF1642A-76A9-4D6F-A437-3E0AFE138452