2 7. See Exhibit E attached to the end of the revised application. Two conditions are requested; the <br />approval of a gravel driveway and eliminating the 30’ buffer. 8. See comment to 2 from environmental health; a well permit has been issue for the site. The septic <br />system design is near completion however, given the pending approval of this application, a septic <br />permit application has not been submitted as of yet. <br />Site Plan 1. Building height and finished floor elevations are provided for the primary building, the only <br />building currently or planned to be in use. Given the age of the buildings on site, there are no <br />existing drawings to confirm these dimensions. The outbuildings are old farm structures - only one <br />of which is in use as a storage shed - do not have finished floor elevations, it’s either bare earth <br />beneath the structure or the floor is too dilapidated to determine and elevation. 2. The existing stream and the required 65’ buffer have been updated and labeled on the site plan. 3. Primary tree protection area is labeled on the site plan with in the existing tree line has no mass <br />clearing is proposed with this application. The tree protection area is fenced in with TP linetype. 4. Added to site plans sheet. 5. Added to site plans sheet. 6. Added to site plans sheet. 7. Added to site plans sheet. 8. Please see the requested conditions to eliminate 30’ buffer. 9. Added to site plans sheet. 10. Please see the requested condition for a gravel surface drive 11. The lighting model has been updated with the existing vegetation and proposed supplemental <br />plantings at the property line that will help to screen lighting and reduce to the footcandles below <br />0.25 at the adjacent property lines. 12. The site plan has been updated to show the proposed stacking area with room for at least three <br />cars. It should also be noted that the staggered pickup times allow for more availability of parking <br />spaces which reduce stacking in the drive-aisles. 13. All pick up and dropoff areas are on site, the stacking area has been identified on the site plan. 14. ADA route has been added an labeled on the site plan. 15. Sight distance triangles have been added to the site plan. 16. No existing signs on site. 17. A floorplan showing the dimensions is included on the OC Property Record card included with this <br />submittal. 18. Required outdoor play area is listed in the site information table. Notes labeling the outdoor area <br />list the provided square footage and have been updated to include ground cover type. 19. This note has been added as note 13 under project notes on the cover sheet. <br />151