Orange County NC Website
2 <br /> Physical Description: <br /> The southern portion of the site is open pasture, defined by a series of mild teraces. <br /> The northern potion of the site is a mixture of small hardwoods on gently sloped terrain. <br /> A 100-foot wide Duke Power transmission line crosses the site(from east to west) near the <br /> central section. <br /> • No drainageways orfloodplaln areas are associated with site. <br /> Proposed She Conditions <br /> Roads: <br /> • The subdivision will be accessed from Davis Road (SR 1120). <br /> • Linnet Drive will be public and constructed to NGDOT standards. <br /> Five feet of additional rightof-way offered along Davis Road <br /> • Road does not have to be extended since no potential far further development. <br /> Residential Lots: <br /> • Six (6)single-family residential Iota on the conventional development option <br /> Average lot size = 3.4 acres; Gross lot site 3.5 acres <br /> • Minimum lot size per R-1 Zoning District= 40.000 square feet <br /> • Minimum lot size using Individual wall and septic systems =40.000 square het <br /> • Minimum to actual lot size ratio(MTAR)3.7 <br /> • Minimum to actual density map(MTADR)3.7 <br /> The property is not located within a protected watershed; impervious surface limits do not <br /> apply <br /> Open Space: <br /> Minimum open space requi si Conventional Development=0% of site <br /> 20,370 square feet (0.47 acre)of open space shall be reserved for private recreation use <br /> Approximately 6.57 (31%)additional acres will be protected through private covenants <br /> and potential conservation easement. <br /> • 28,314 square feet (0.85 acre)of open space in Davis Road (building setback)buffer <br /> 5.92 acres in northem conservation area proposed on lots 5 and 6 for private use <br /> Buffers: <br /> The applicant has self-imposed a 100-foot building setback buffer along Davis Road. (There <br /> is no building buffer requirement for conventional subdivisions. Septic systems may be <br /> placed within 70 feet of this buffer.) <br /> Land Use Buffer <br /> A 30-foot Type-A Land Use Buffer(semlopaque: intermittent visual obstructions from the <br /> ground m a height of at least thirty feet)is required! along Davie Road per Section IV-B-e. <br /> A 50 foot Type-D Land Use Buffer(semiopaque: 50-75% evergreen vegetation <br /> distributed so as as create a senn opmque screen to a height of at least thirty feet)is <br /> required along either side of the overhead electrical power transmission line per Section <br /> V-B-B. <br /> A typical lot landscape plan shows primary and secondary tree protection areas. <br />