Browse
Search
2023-661-E-Hamlett Associates-RFP5399 - Whitted Stormwater Improvements Project
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2023
>
2023-661-E-Hamlett Associates-RFP5399 - Whitted Stormwater Improvements Project
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:43:28 PM
Creation date
11/21/2023 2:39:10 PM
Metadata
Fields
Template:
Contract
Date
11/14/2023
Contract Starting Date
11/14/2023
Contract Ending Date
11/15/2023
Contract Document Type
Contract
Amount
$3,600.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
364
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9/2/2020 <br /> <br />33 46 00 SUBDRAINAGE Page 2 of 4 <br />2.3 SOIL MATERIALS <br />A. Soil materials are specified in Section 31 20 00 "Earth Moving." <br />2.4 WATERPROOFING FELTS <br />A. Material: Comply with [ASTM D 226, Type I, asphalt] [or] [ASTM D 227, coal-tar]-saturated <br />organic felt. <br />2.5 GEOTEXTILE FILTER FABRICS <br />A. Description: Fabric of PP or polyester fibers or combination of both, with flow rate range from <br />110 to 330 gpm/sq. ft.when tested according to ASTM D 4491. <br />B. Structure Type: Nonwoven, needle-punched continuous filament. <br />1. Survivability: AASHTO M 288 Class 2. <br />2. Styles: Flat and sock. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine surfaces and areas for suitable conditions where subdrainage systems are to be installed. <br />B. If subdrainage is required for landscaping, locate and mark existing utilities, underground <br />structures, and aboveground obstructions before beginning installation and avoid disruption and <br />damage of services. <br />C. Verify that drainage panels installed as part of foundation wall waterproofing is properly <br />positioned to drain into subdrainage system. <br />D. Proceed with installation only after unsatisfactory conditions have been corrected. <br />3.2 EARTHWORK <br />A. Excavating, trenching, and backfilling are specified in Section 31 20 00 "Earth Moving." <br />3.3 FOUNDATION DRAINAGE INSTALLATION <br />A. Foundation drainage shall be constructed as shown in the Drawings and per manufacturer <br />recommendations. <br />DocuSign Envelope ID: 7D9ACD4F-8F6C-42B6-9ADB-C60032DB6D03
The URL can be used to link to this page
Your browser does not support the video tag.