Orange County NC Website
D E S I G N C R I T E R I A <br />BUILDING CODE: CONCRETE <br />DESIGN CODE: CONCRETE <br />DESIGN METHOD: STEEL <br />DESIGN CODE: STEEL DESIGN <br />METHOD: STEEL JOISTS: <br />NORTH CAROLINA STATE BUILDING CODE, 2018 EDITION <br />ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE EQUIV. <br />RECTANGULAR STRESS BLOCK <br />AISC MANUAL OF STEEL CONSTRUCTION, LRFD, FOURTEENTH EDITION ELASTIC ANALYSIS, <br />PLASTIC DESIGN <br />SJI STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS AND LONGSPAN JOISTS <br />S N O W L O A D <br />TERRAIN CATEGORY <br />GROUND SNOW LOAD (Pg) <br />SNOW EXPOSURE FACTOR (Ce) <br />THERMAL FACTOR (Ct) <br />SNOW IMPORTANCE FACTOR (Is) <br />FLAT ROOF SNOW LOAD (Pf) <br />B <br />15 PSF <br />1.0 <br />1.0 <br />1.0 <br />15 PSF <br />W I N D L O A D S <br />MINIMUM WIND LOAD <br />BASIC WIND VELOCITY <br />RISK CATEGORY <br />WIND EXPOSURE CATEGORY <br />INTERNAL PRESSURE COEFFICIENT <br />COMPONENTS & CLADDING <br />10 PSF <br />115 MPH <br />II <br />B <br />±0.18 <br />CALCULATED BY PROVIDER PER ASCE 7-10 <br />S E I S M I C D A T A <br />BUILDING OCCUPANCY CATEGORY <br />SEISMIC IMPORTANCE FACTOR (IE) <br />MAPPED SPECTRAL RESPONSE ACCELERATION (SS) <br />MAPPED SPECTRAL RESPONSE ACCELERATION (S1) <br />SITE CLASS <br />DESIGN SPECTRAL RESPONSE ACCELERATION (SDS) <br />DESIGN SPECTRAL RESPONSE ACCELERATION (SD1) <br />SEISMIC DESIGN CATEGORY <br />BASIC SEISMIC FORCE RESISTING SYSTEM <br />RESPONSE MODIFICATION FACTOR (R) <br />DEFLECTION AMPLIFICATION FACTOR (Cd) <br />DESIGN BASE SHEAR <br />NORTH-SOUTH DIRECTION <br />EAST WEST DIRECTION <br />ANALYSIS PROCEDURE <br />II <br />1.0 <br />20.0% <br />7.8% <br />D <br />21.3% <br />12.5% <br />B <br />NOT DETAILED <br />3.00 <br />3.00 <br />N/A <br />N/A <br />EQUIV. LAT. FORCE <br />L I V E L O A D S <br />SLAB ON GRADE 200 PSF <br />ROOF (MINIMUM) 17.5 PSF <br />G E N E R A L N O T E S <br />1.THE STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, MECHANICAL AND ELECTRICAL DRAWINGS. <br />2.THE CONTRACTOR WILL COORDINATE BETWEEN ALL TRADES. CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND THE DRAWINGS OF <br />OTHERS WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER IN A TIMELY FASHION THAT PERMITS <br />CLARIFICATIONS WITHOUT EFFECTING THE CONSTRUCTION SCHEDULE. <br />3.THESE DRAWINGS ALONG WITH ANY SPECIFICATIONS ISSUED CONSTITUTE THE CONTRACT DESIGN DOCUMENTS FOR THIS PROJECT. ANY <br />DISCREPANCY BETWEEN THE TWO WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR STRUCTURAL ENGINEER FOR CLARIFICATION. FOR <br />ESTIMATING PURPOSES THE CONTRACTOR WILL ASSUME THE MORE COSTLY ALTERNATIVE. NO MATERIALS MAY BE ORDERED, AND NO WORK <br />MAY PROCEED UNTIL THE DISCREPANCY IS RESOLVED BY THE DESIGN PROFESSIONAL. <br />4.ALTERNATES OR SUBSTITUTIONS TO STRUCTURAL MATERIALS OR DESIGN ARE AT THE SOLE DISCRETION OF THE LICENSED STRUCTURAL <br />ENGINEER OF RECORD. ANY MODIFICATION MUST BE APPROVED IN THE MANNER SET FORTH IN THE "FRONT END" SPECIFICATIONS. <br />5.ALL STANDARDS REFERENCED WITHIN THESE DOCUMENTS ARE TO BE THE EDITIONS REFERENCED IN CHAPTER THIRTY-FIVE OF THE <br />INTERNATIONAL BUILDING CODE. <br />6.STRUCTURAL MEMBERS, INCLUDING BEAMS, COLUMNS, JOISTS, TRUSSES, WALLS, SLABS AND BRACING ELEMENTS, ARE DESIGNED FOR THE <br />FINAL DESIGN LOADS GIVEN ON THIS SHEET. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING AND BRACING. SHORING IS TO BE <br />DESIGNED TO PRECLUDE THE OVERSTRESSING ANY STRUCTURAL ELEMENT (AS REQUIRED AT ANY STAGE OF CONSTRUCTION) UNTIL COMPLETION <br />OF THIS PROJECT. <br />7.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ON-SITE SAFETY. AT A MINIMUM, THE CONTRACTOR IS TO RESEARCH AND IMPLEMENT ALL <br />SAFETY REGULATIONS IN FORCE IN THE JURISDICTION OF THIS PROJECT. PRIOR TO THE COMMENCEMENT OF WORK, THE CONTRACTOR WILL <br />BRING TO THE ATTENTION OF THE STRUCTURAL ENGINEER ANY STRUCTURAL DETAIL THAT WOULD PRODUCE AN UNUSUALLY UNSAFE CONDITION. <br />F O U N D A T I O N S <br />1.THE PRIMARY BUILDING STRUCTURE IS DESIGNED FOR SUPPORT ON SPREAD FOOTINGS WITH AN ASSUMED ALLOWABLE NET SOIL <br />BEARING PRESSURE OF 2000 PSF ON UNDISTURBED SOILS OR COMPACTED FILL. <br /> <br />2.IF SOIL AT THE SCHEDULED FOOTING ELEVATION IS OF QUESTIONABLE BEARING VALUE, THE ARCHITECT AND STRUCTURAL ENGINEER <br />ARE TO BE NOTIFIED IMMEDIATELY. LOWER FOOTING ELEVATIONS IF REQUIRED BY ARCHITECT AND ENGINEER TO REACH FIRM SOIL. <br />3.CONTRACTOR IS TO PROVIDE PROPERLY DESIGNED SHEETING AND SHORING AT ALL OPEN EXCAVATIONS, OR LAY BACK THE CUT AT A <br />SLOPE APPROVED BY THE ON-SITE GEOTECHNICAL ENGINEER IN ORDER TO ENSURE SAFE WORKING CONDITIONS AND AS NECESSARY TO <br />COMPLY WITH ALL APPLICABLE CODES AND REGULATIONS. ALL EXCAVATIONS SHALL BE ADEQUATELY DEWATERED BEFORE PLACEMENT <br />OF CONCRETE. <br />C O N C R E T E <br />1.ALL CONCRETE WORK SHALL COMPLY WITH THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS, ACI-301 AND THE <br />BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI-318 (EDITIONS IN FORCE). <br />2.CONCRETE MIX DESIGNS ARE REFERENCED IN THE PROJECT SPECIFICATIONS. FOR EACH DESIGN A SUBMITTAL WILL BE MADE BY THE <br />CONTRACTOR AS OUTLINED IN THE SPECIFICATIONS. <br />3.ALL REINFORCING STEEL IS TO BE TIED TO PREVENT DISPLACEMENT DURING CONCRETE PLACEMENT. TACK WELDING OF <br />REINFORCEMENT STEEL IS PROHIBITED. <br />4.THE CONTRACTOR WILL SUBMIT A COMPLETE LIST OF ACCESSORIES AND PLACING DETAILS WITH SHOP DRAWINGS. <br />5.ALL REINFORCING STEEL IS TO BE CONTINUOUS. LAP BARS 40 DIAMETERS FOR BARS #6 AND SMALLER OR 48 DIAMETERS FOR BARS #7 <br />AND LARGER AT SPLICE UNLESS NOTED OTHERWISE ON SCHEDULES OR DETAILS. <br />6.THE LOCATION OF ALL LAP SPLICES WILL BE SHOWN ON SHOP DRAWINGS. <br />7.NO CONCRETE ELEMENT MAY BE CORED TO PLACE THROUGH ITEMS (ie PIPES, ELECTRICAL LINES, ETC.). ALL THROUGH ITEMS <br />PENETRATING HORIZONTAL SURFACES ARE TO BE PLACED IN SCHEDULE 40, STEEL, PIPE SLEEVES OF A DIAMETER SUFFICIENT TO <br />ACCOMMODATE THE THROUGH ITEM. AT PENETRATIONS IN THE VERTICAL PLANE OF ELEMENTS THE PIPE SLEEVE DIAMETER WILL BE <br />INCREASED BY AN AMOUNT TO PROVIDE 1 1/2" CLEAR DIMENSION AROUND THE THROUGH ITEM. <br />8.REFER TO ARCHITECTURAL DRAWINGS FOR ALL WATERPROOFING OF CONCRETE BELOW GRADE. <br />9.NO HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED IN CONCRETE ELEMENTS. LOCATE VERTICAL CONSTRUCTION JOINTS AT THE <br />MIDDLE THIRD OF THE SPAN. PROVIDE 2x4, CONTINUOUS, BEVELED KEYWAYS AT SLABS AND (ONE MINIMUM) AND 2X8 BEVELED KEYWAY AT <br />BEAMS. SUBMIT PROPOSED CONSTRUCTION JOINT LOCATIONS TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL. <br />10.ALL INTERSECTING BEAMS, WALLS, AND FOOTINGS SHALL HAVE CORNER BARS. REFER TO TYPICAL DETAILS. <br />S T E E L <br />1.DIMENSIONS GIVEN ON THE STRUCTURAL DRAWINGS ARE PROVIDED AS A CONVENIENCE AND ARE SOLELY TO CONVEY THE QUANTITY AND <br />NATURE OF THE STRUCTURAL STEEL LAYOUT. ALL FINAL DIMENSIONS ARE TO BE COORDINATED BY THE CONTRACTOR WITH THE PROJECT <br />ARCHITECT BEFORE MATERIAL IS ORDERED OR FABRICATIONS HAS BEGUN. <br />2.UNLESS SPECIFICALLY INDICATED OTHERWISE ON THE DRAWINGS, SHEAR CONNECTIONS ARE TO BE DESIGNED USING THE AISC ALLOWABLE <br />STRESS DESIGN METHOD FOR THE MINIMUM SERVICE LOAD REACTIONS PROVIDED ON THE FRAMING PLANS. ADDITIONALLY, SINGLE ANGLE <br />CONNECTIONS ARE PROHIBITED AND MEMBERS WILL BE FURNISHED WITH A MINIMUM NUMBER OF WEB BOLT ROWS AS FOLLOWS: <br /> MEMBER DEPTH MIN. NUMBER OF WEB BOLT ROWS <br /> W4 -W10 2 BOLTS <br /> W12 OR GREATER 3 BOLTS <br /> <br />3.GENERALLY, 3/4" DIA., ASTM A-325-N BOLTS ARE TO BE USED FOR ALL BOLTED SHEAR CONNECTIONS UNLESS OTHERWISE INDICATED. THE <br />FABRICATOR MAY USE OTHER DIAMETER BOLTS WHERE AISC RECOMMENDATIONS REQUIRE A SMALLER BOLT FOR GAGE OR BLOCK SHEAR <br />REASONS OR WHERE STRENGTH REASONS REQUIRE LARGER DIAMETER BOLTS. THE PROVIDER OF BOLTS WILL PAINT THE HEADS OF THE <br />NONSTANDARD BOLTS WITH IDENTIFYING COLORS UNIQUE TO A PARTICULAR DIAMETER OF BOLT AND WILL STRIPE THE FRAMING MEMBER AT THE <br />CONNECTION SITE OUTSIDE THE FAYING SURFACE WITH THE CORRESPONDING COLOR. <br />4.FULLY TENSION ALL BOLTS WHERE DESIGNATED ON STRUCTURAL DRAWINGS AND AT MOMENT CONNECTIONS, INCLUDING BOLTS RESISTING <br />ONLY GRAVITY LOADS. PROVIDE ASTM A-325-SC BOLTS AT CONNECTIONS WHERE INDICATED ON DRAWINGS. PREPARE FAYING SURFACES AT SUCH <br />CONDITIONS PER AISC REQUIREMENTS. <br />5.SINGLE PLATE SHEAR CONNECTION IS THE PREFERRED METHOD OF ATTACHMENT BETWEEN BEAMS AND GIRDERS AND WHERE HORIZONTAL <br />FRAMING MEMBERS ATTACH TO COLUMNS AT ANGLES OTHER THAN 90°. <br />6.COLD BENDING OF PLATE MATERIAL IS NOT PERMITTED FOR USE IN SKEWED CONNECTIONS. HEAT MEMBER OR BUILD UP FROM TWO PLATES <br />AS REQUIRED AND FULLY TEST ANGLE FOR WELD DEFECTS. <br />7.ALL COPES AND CUTS IN STRUCTURAL MEMBERS ARE TO BE MADE FREE OF NOTCHES OR OTHER STRESS CONCENTRATORS. COPES ARE TO <br />BE CUT AT A MINIMUM RADIUS OF 1/2". <br />8.ALL ROLLED STEEL MEMBERS ARE TO FABRICATED WITH MILL CAMBER UP. <br />9.COLUMN SPLICES ARE NOT ANTICIPATED ON THIS PROJECT. THE FABRICATOR MAY REQUEST COLUMN SPLICES SUBJECT TO APPROVAL BY THE <br />STRUCTURAL ENGINEER OF RECORD. ALTHOUGH THE ACTUAL TYPE OF SPLICE WILL BE DETERMINED ON AN INDIVIDUAL BASIS, AISC TYPE VIIID <br />COLUMN SPLICES MAY BE ASSUMED FOR PRICING PURPOSES. <br />10.ALL WELDS ARE TO CONFORM WITH ANSI/AWS D1.1 STANDARD AND ARE TO BE MADE BY CERTIFIED WELDERS. <br />11.ALL FULL AND PARTIAL PENETRATION WELDS IN MOMENT CONNECTIONS ARE TO MEET CYCLICAL LOADING STANDARDS. <br />12.A WELD SCHEDULE FOR ALL FIELD WELDS WILL BE FURNISHED BY THE ERECTOR. THIS SCHEDULE IS TO BE PREPARED BY A COMPETENT <br />DESIGNER OF WELDS AND WILL INDICATE AT A MINIMUM PREHEAT, THE WELD FILLER MATERIAL, THE PROPER WELD DEPOSITION RATE AND THE <br />WELDING MACHINE SETTINGS. <br />13.THE TOP FLANGES OF ALL MEMBERS ARE TO REMAIN UN-PRIMED AND UNPAINTED UNLESS EXPOSED TO VIEW. ADDITIONALLY, MEMBERS TO <br />RECEIVE SPRAY APPLIED FIRE PROOFING OR MEMBERS EMBEDDED OR ENCASED IN CONCRETE ARE TO REMAIN UN-PRIMED AND UNPAINTED <br />14.ALL STEEL ELEMENTS AND CONNECTIONS WHICH WILL BE PERMANENTLY EXPOSED TO EXTERIOR CONDITIONS SHALL BE HOT DIP GALVANIZED <br />AFTER FABRICATION. <br />S T E E L J O I S T S <br />1.STEEL JOISTS SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST STEEL JOIST INSTITUTE SPECIFICATIONS. <br />JOIST MANUFACTURER SHALL BE A MEMBER OF THE S.J.I. <br />2.UNLESS SPECIFICALLY INDICATED OTHERWISE ON THE DRAWINGS, K-SERIES JOISTS SHALL BEAR A MINIMUM OF 21/2" ON STEEL SUPPORTS <br />AND EACH END SHALL BE WELDED TO SUPPORTS USING A MINIMUM OF 2 -1/8" x 1" LONG FILLET WELDS. INCREASE WELD SIZE AND LENGTH AS <br />REQUIRED TO SATISFY UPLIFT REQUIREMENTS. <br />3.BOLT JOISTS AT COLUMN LINES IN ACCORDANCE WITH S.J.I. STANDARD SPECIFICATIONS AND PROVIDE BOTTOM CHORD EXTENSIONS. <br />4.JOIST BRIDGING IS INDICATED SCHEMATICALLY ON THE STRUCTURAL DRAWINGS. PROVIDE HORIZONTAL AND/OR DIAGONAL BRIDGING AND <br />ACCESSORIES AS REQUIRED TO FULLY COMPLY WITH S.J.I. SPECIFICATIONS AND TO RESIST THE UPLIFT PRESSURES INDICATED. <br />5.PROVIDE TOP CHORD EXTENSIONS AND CEILING EXTENSIONS AS INDICATED AND AS NECESSARY TO SATISFY ARCHITECTURAL <br />REQUIREMENTS. <br />M A T E R I A L S <br />1.STEEL <br />WIDE FLANGE MEMBERS ASTM A992, Fy = 50KSI <br />ANGLES & CHANNELS ASTM A36, Fy = 36KSI <br />PLATES & BARS (GENERAL)ASTM A36, Fy = 36KSI <br />PLATES & BARS (MOMENT CONNECTIONS)ASTM A572, Fy = 50KSI <br />HOLLOW STRUCTURAL SECTIONS (RECTANGULAR)ASTM A500 GRADE B, Fy = 46KSI <br />MISCELLANEOUS PIPES ASTM A53, Fy = 35KSI <br />BOLTS (FRAMING MEMBERS)ASTM A352-N <br />ANCHOR RODS ASTM F1554 GRADE 55, WELDABLE <br />ROOF DECKING ASTM A653SQ, GRADE 33 GALV. <br />2.REINFORCING STEEL <br />GENERAL REINFORCING ASTM A615, Fy = 60KSI <br />WELDED WIRE FABRIC ASTM A185, IN FLAT SHEETS <br />3.WELD ELECTRODES <br />GENERAL -ROLLED OR FORMED MEMBERS E70xx ELECTRODES, CVN = 20#-FT AT 40 DEG. <br />DECKING TO FRAME WELDS E70xx OR E60xx <br />4.CONCRETE <br />FOOTINGS MIX F'c = 3000PSI NORMAL WEIGHT <br />SLABS ON GRADE MIX F'c = 4000PSI NORMAL WEIGHT <br />5.GROUT F'c = 3000PSI <br />FIRE PROTECTION <br />1.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING SEALED FIRE PROTECTION DESIGN AS REQUIRED BY NC BUILDING CODE. <br />1 <br />1 <br />CERT. NO. <br />52006REGISTEREDARCHITECTURALCOMPANY <br />N <br />ORTH CA R O L INA <br />SUMMITDESIGNAND E N GINEERIN <br />G <br />SERVICES,PLLCRALE I G HCreatively Inspired - Technically ExecutedLicense #: P-03392715 Ashton Dr., Suite 104Wilmington, NC 28412Voice: (910) 475-1208 Fax: (919) 322-0116www.SummitDE.comDESIGN AND ENGINEERING SERVICESPROJECT NO. <br />SHEET NO. <br />THIS DRAWING & THE DESIGN INTENT OF THIS <br />INSTRUMENT OF SERVICE IS THE VESTED <br />PROPERTY OF THE ARCHITECT & THE <br />ARCHITECTS CONSULTANTS, WHICH ARE NOT <br />TO BE REPRODUCED IN WHOLE OR IN PART BY <br />ANY MEANS OR METHOD WITHOUT EXPRESS <br />WRITTEN CONSENT OF THE ARCHITECT. THIS <br />INSTRUMENT OF SERVICE IS SOLELY & <br />EXCLUSIVELY FOR THE PURPOSE OF <br />CONSTRUCTING, USING, MAINTAINING, <br />ALTERING & ADDING TO THIS SPECIFIC <br />PROJECT AT IT'S SPECIFIC LOCATION. <br />COPYRIGHT 2015 <br />SUMMIT DESIGN AND <br />ENGINEERING SERVICES <br />C <br />ENGINEER OF RECORD <br />PROJECT MANAGER <br />DRAWN BY FIRST ISSUE DATE <br />500 VALLEY FORGE RDHILLSBOROUGH, NC, 2727818-0299 <br />S.1 <br />UO, SDH 3/14/2019 <br />JET <br />JET <br />GENERAL NOTESFREEZER ADDITIONPIEDMONT FOOD & AGRIC.NOREVISIONSDATEBY1CODE CHANGE & DETAILREVISIONSJET7/11/23 <br />DocuSign Envelope ID: 7129A8A1-2F7E-4B61-B405-CDEC9F69B66B