Orange County NC Website
DocuSign Envelope ID:77803446-26E8-4424-B3DD-15F947931AE8 <br />3) Work will commence during normal working hours Monday through Friday(8—5 PM)Eastern Time. <br />4) All installation work will be performed through a remote connection from BCS headquarters. <br />5) Once the installation is completed,acceptance testing is performed by BCS in conjunction with Licensee staff to ensure <br />successful operation.The implementation phase of the project is complete once a substantial majority of the software is <br />installed.At the point that sufficient software has been installed to consider the application to be operational,it is <br />transitioned from implementation to maintenance. <br />LICENSEE RESPONSIBILITIES <br />In order to complete a successful implementation,Licensee will need to provide the following: <br />1. Interface to the CAD system in accordance with"MARVLIS Server Computer Aided Dispatch Integration Guide"that will <br />provide the necessary information to MARVLIS Server for dispatches, status changes, and incident locations (Lat/Long) <br />as well as receiving status changes and vehicle locations from MARVLIS Server. <br />a. CAD system should provide the following information: <br />i. Incident Identification Number <br />ii. Incident location(Lat/Long) <br />iii. Incident Address <br />iv. Vehicle assigned identification <br />v. Priority <br />vi. Problem Nature <br />vii. Dispatcher Comments,if applicable <br />Updates to incident information sent after initial dispatch must include the Incident Identification <br />Number as a minimum <br />b. CAD should provide the following information for status changes initiated by CAD <br />i. Vehicle Identification <br />ii. New Status to be displayed <br />c. If status changes initiated by the vehicle are to be transmitted to CAD,provide the interface to accept the <br />changes from MARVLIS. Data to be sent to CAD will include as a minimum; <br />i. Vehicle Identification <br />ii. New Status <br />MARVLIS IMPLEMENTATION DEPENDENCIES: <br />The items below are needed to support the MARVLIS software and are not the responsibility of BCS. These items should be <br />established by customer prior to installation by BCS. <br />1. The communications infrastructure to provide wireless connectivity between MARVLIS Client and MARVLIS Server <br />must be available. MARVLIS Client and MARVLIS Server use TCP/IP communications protocols. <br />a. Wireless device should be configured to automatically reestablish communications if lost due to coverage or <br />obstacles. <br />b. Connection from vehicles to Server should be tested to assure end-to-end connectivity. <br />2. The in-vehicle hardware to support MARVLIS Client functions must be available and installed in the vehicles. This <br />would include the GPS device,the wireless modem device,and a rugged laptop. <br />a. GPS device should be configured to send location to Client as a NMEA or TAIP string once per second. <br />b. Laptop should be installed and communications tested to assure that the laptop can communicate to the Server. <br />3. The existing OSSI CAD interface must be installed,configured and tested in order to allow the transmission of status <br />changes etc.between the OSSI and MARVLIS applications. <br />a. NOTE:BCS will coordinate with OSSI to test the objectives of the interface. However,the BCS quotation does <br />not include compensating OSSI for their interface. <br />4. The computer hardware to support the remaining MARVLIS applications must be available for installation and <br />configuration.All systems should be connected to the internal network and configured to communicate with each other <br />and with the CAD Server. The Server will also require communications access to the outside network so that Clients can <br />connect. <br />B-5 <br />CORE/0804998.0008/128897050.2 <br />DocuSign Envelope ID: 3A3B749D-89FA-4DD4-AB4B-396224600A6A