Browse
Search
Agenda - 04-04-2023; 5-b - Application for Zoning Atlas Amendment – Parcel Located at 3026 White Cross Road, Chapel Hill, in Bingham Township
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2020's
>
2023
>
Agenda - 04-04-2023 Business Meeting
>
Agenda - 04-04-2023; 5-b - Application for Zoning Atlas Amendment – Parcel Located at 3026 White Cross Road, Chapel Hill, in Bingham Township
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2023 12:12:34 PM
Creation date
3/30/2023 12:17:09 PM
Metadata
Fields
Template:
BOCC
Date
4/4/2023
Meeting Type
Business
Document Type
Agenda
Agenda Item
5-b
Document Relationships
Agenda for April 4, 2023 BOCC Meeting
(Message)
Path:
\Board of County Commissioners\BOCC Agendas\2020's\2023\Agenda - 04-04-2023 Business Meeting
OTHER-2023-021-Expansion of Duke Energy Utility Easement at Gravely Hill Middle School
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2023
OTHER-2023-022-Approval of financing arrangements for Efland volunteer fire department for renovation of fire station 1
(Message)
Path:
\Board of County Commissioners\Various Documents\2020 - 2029\2023
PRO-2023-003-Public Safety Telecommunicators Week Proclamation
(Message)
Path:
\Board of County Commissioners\Proclamations\2020-2029\2023
PRO-2023-004-Native Plant Month Proclamation
(Message)
Path:
\Board of County Commissioners\Proclamations\2020-2029\2023
RES-2023-023-Refund-Release Resolution-Approval
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2023
RES-2023-024-Refund-Release Resolution-Approval
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2023
RES-2023-025-Exemption-Exclusion Resolution
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2023
RES-2023-026-Proposed Sale of 0.45 Acre Property, PIN #0900832203, Hillsborough
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2023
RES-2023-027-Resolution Supporting Legislation to Reclassify Telecommunicators
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2023
RES-2023-028-Approval of in county travel allowance for Orange County schools board of education members
(Message)
Path:
\Board of County Commissioners\Resolutions\2020-2029\2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
146 <br /> g m'rral 11,617 <br /> 1003 Gregory Fork Road <br /> Richlands, NC 28574 <br /> Phone (910)330-2784 <br /> pittmansoil@yahoo.com <br /> ------------------------------------------------------------- <br /> SEPTEMBER 2,2022 <br /> Ref: Dollar General site located on NC HWY 54 WHITE CROSS RD, CARRBORO, NC <br /> A soil evaluation was conducted on the above referenced tract to determine the sites <br /> suitability for septic repair. The current laws and rules of NC was used as guide for this <br /> evaluation. <br /> This evaluation was conducted for a 200 gpd Dollar General. Hand Auger borings on the <br /> site were used to characterize the soil texture, and depth to the soil wetness condition. <br /> The attached plot plan shows the location of the septic system in the most ideal location <br /> on the site. The soil wetness condition was found to be 30" from the surface with a clay <br /> loam texture. I have assigned an LTAR of 0.33 gpd/sqft for a 200 gpd Dollar General. <br /> This will require the installation of 4-60'conventional lines that shall be installed in <br /> accordance with the current rules and on contour. The depth to soil wetness of 30" <br /> would constitute a 12-18"trench bottom. The system will require 6" of Group II or III <br /> soil cover that shall extend 5'from the edge of the system. The system will require a <br /> 1500 gallon septic tank and a 1000 gallon pump tank. <br /> The repair will require 4-60'conventional lines installed at 12-18" from the surface. <br /> After installation the site should be landscaped to shed surface water. Any alterations to <br /> the site may impact soil conditions. This does not constitute a warranty or guarantee of <br /> system performance or functionality. <br /> If you have any questions please feel free to contact me at 910-330-2784. Thank You. <br /> Sincerely, <br /> �p 50LL 5��N,S, <br /> f�aoo°_ <br /> - oo�,Oc� A�as <br /> sl9E �, <br /> R. Haywood Pittman II <br /> NC Licensed Soil Scientist <br />
The URL can be used to link to this page
Your browser does not support the video tag.