Orange County NC Website
REF. REF. <br />W D <br />W D <br />DW <br />5.102 <br />5.10 <br />5.10 5 <br />4 <br />200 <br />LOBBY <br />121 <br />BAYS <br />APPARATUS <br />102 <br />CORRIDOR <br />100 <br />LOBBY <br />103 <br />WORKROOM <br />GENERAL <br />101 <br />TOILET 105 <br />DAYROOM <br />119 <br />LAUNDRY <br />DECON. <br />118 <br />STORAGE <br />GENERAL <br />109 <br />CORRIDOR <br />115 <br />SHOWER <br />TOILET <br />114 <br />SHOWER <br />TOILET 108 <br />EXERCISE <br />110 <br />ROOM <br />BUNK <br />111 <br />ROOM <br />BUNK <br />112 <br />ROOM <br />BUNK <br />113 <br />ROOM <br />BUNK <br />107 <br />CORRIDOR <br />104 <br />KITCHEN <br />116 <br />VESTIBULE <br />120 <br />VESTIBULE <br />121A <br />A <br />-13 <br />121B <br />A <br />-13 <br />121C <br />B <br />-13 <br />121D <br />B <br />-13 <br />201 <br />K1 <br />162 <br />119A <br />J <br />104 <br />116 <br />G1 <br />84 <br />118A <br />H <br />134 <br />103 <br />K <br />1514 <br />101 <br />L <br />93 <br />118B <br />N <br />2114 <br />115 <br />L <br />916 <br />114 <br />L <br />916 <br />112 <br />M <br />1117 <br />111 <br />M <br />1117 <br />110 <br />M <br />1117 <br />100B <br />E <br />25 <br />108 <br />D <br />66 <br />119B <br />N <br />182 <br />100A <br />C <br />110 <br />200 <br />C <br />111 <br />109A <br />K <br />72 <br />105 <br />C <br />112 <br />109B <br />J1 <br />418 <br />102 <br />K <br />72 <br />205 <br />T/T1 <br />59 <br />207 <br />H/H <br />38 <br />121E <br />G <br />47 <br />123 <br />PATIO <br />1 <br />5.20 <br />2 <br />5.20 <br />7 <br />5.20 <br />8 <br />5.20 <br />5 <br />5.20 <br />3 <br />5.20 <br />4 <br />5.20 <br />6 <br />5.20 <br />SLOPE 1/8"/FT. <br />TO DRAIN <br />SLOPE 1/8"/FT. <br />TO DRAINSLOPE 1/8"/FT. TO DRAINSLOPE 1/8"/FT. TO DRAIN4'x7' DOOR AS <br />SUPPLIED BY <br />COOLER MANU. <br />SLOPE 1/8"/FT. <br />TO DRAIN <br />SLOPE 1/8"/FT. <br />TO DRAINSLOPE 1/8"/FT. TO DRAINSLOPE 1/8"/FT. TO DRAIN4.80 <br />1 <br />4.80 <br />2 <br />4.80 <br />3 <br />4.80 <br />4 <br />106 <br />I.T. <br />106 <br />P/P <br />141 <br />4.21 <br />1104 <br />F <br />2215 <br />5.103 <br />4.20 <br />2 4.20 <br />1 <br />OXYGEN TANK <br />STORAGE <br />RACK BY <br />OWNER <br />204 <br />O <br />192 <br />W1 <br />W7 <br />ABOVE. <br />SEE ELEV. <br />202 <br />SHOWER <br />TOILET <br />203 <br />WORK ROOM <br />206 <br />COOLER <br />204 <br />CLOSET <br />JANITOR <br />207 <br />ELEC. ROOM <br />201 <br />CORRIDOR <br />205 <br />WORK AREA <br />EXAMINERS <br />117 <br />JANITOR <br />136 <br />G1 <br />84 <br />113 <br />M <br />1117 <br />117 <br />N <br />122 <br />122 <br />R/R <br />172 <br />203 <br />S <br />202 <br />202 <br />L1 <br />92 <br />W2 <br />W2 <br />W6 <br />W5 <br />W5 <br />W4 W4 W4 W4 <br />W3 <br />5.10 <br />6 <br />5.40 <br />4 <br />3 <br />5.31 <br />W8 <br />CR CR <br />CR <br />CR <br />CR <br />CR <br />CR <br />CR <br />CR CR <br />4.81 <br />1 <br />4.20 <br />7 <br />--- <br />- <br />4.20 <br />9 <br />4.20 <br />10 <br />--- <br />- <br />4.20 <br />11 <br />4.20 <br />12 <br />4.20 <br />8 <br />ADD BLOCKING FOR <br />MIRROR WALL <br />4.20 <br />13 <br />4.20 <br />14 <br />1.71 <br />7 <br />4.20 <br />16 <br />4.20 <br />17 <br />4.20 <br />18 <br />4.20 <br />19 <br />4.20 <br />20 <br />4.20 <br />19 <br />Sim <br />4.20 <br />20 <br />Sim <br />CR <br />DOOR TAG <br />WINDOW TAG <br />CARD READER LOCATION <br />FLOOR DRAIN LOCATION <br />CR <br />101 <br />C <br />92 <br />W1 <br />FD <br />METAL STUD WALL <br />ASSEMBLY <br />CMU WALL ASSEMBLY <br />CMU & VENEER WALL <br />ASSEMBLY <br />FLOOR PLAN LEGEND <br />METAL STUD & VENEER <br />WALL ASSEMBLY <br />FLOOR PLAN NOTES <br />1. ALL CONTRACTORS MUST MAKE ON SITE VISITATIONS TO PROJECT SITE PRIOR TO BIDDING TO <br />FAMILIARIZE THEMSELVES WITH THE EXTENT OF CONSTRUCTION. <br />2. DISCREPANCIES: THE CONTRACTOR SHALL INFORM THE ARCHITECT IN WRITING OF ANY <br />DISCREPANCIES OR OMISSIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS OR OF ANY <br />VARIATIONS NEEDED IN ORDER TO CONFORM TO CODES, RULES AND REGULATIONS. UPON <br />RECEIPT OF SUCH INFORMATION, THE ARCHITECT WILL SEND WRITTEN INSTRUCTION TO ALL <br />CONCERNED. ANY SUCH DISCREPANCY, OMISSION OR VARIATION NOT REPORTED SHALL BE THE <br />RESPONSIBILITY OF THE CONTRACTOR AND WORK SHALL BE PERFORMED IN A MANNER DIRECTED <br />BY THE ARCHITECT. <br />3. EXISTING CONDITIONS: ALL EXISTING INFORMATION WAS TAKEN FROM DRAWINGS FURNISHED BY <br />OTHERS WHICH MAY OR MAY NOT BE CORRECT. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, <br />ELEVATIONS AND CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES OR VARIATIONS FROM THE <br />CONDITIONS SHOWN ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE <br />ARCHITECT IN WRITING. <br />4. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONS USING <br />THE SURROUNDING FACILITIES WHO COME INTO CONTACT WITH THE AREA OF CONSTRUCTION. HE <br />SHALL PROPERLY BARRICADE THE AREA TO PREVENT INTRUSION BY PERSONS NOT ASSOCIATED <br />WITH CONSTRUCTION. <br />5. DRAWING SCALES: THESE DRAWINGS ARE PREPARED TO THE SCALE NOTED, HOWEVER, <br />DIMENSIONS ARE NOT TO BE DERIVED BY SCALING THE PLANS, SECTIONS OR DETAILS. IF THERE IS <br />ANY QUESTIONS ABOUT DIMENSIONS OR DETAILS, CONTACT THE ARCHITECT FOR INFORMATION <br />PRIOR TO STARTING WORK. <br />6. ALL NOTES APPLY TO ALL DRAWINGS AND ALL TRADES. IT IS THE RESPONSIBILITY OF ALL <br />CONTRACTORS AND TRADES TO COORDINATE THE INSTALLATION OF THEIR WORK WITH THE <br />INSTALLATION OF WORK BY ALL OTHER CONTRACTORS AND TRADES. <br />7. THE REQUIREMENTS OF THE DRAWINGS, GENERAL REQUIREMENTS AND ALL ITEMS OF THE <br />CONTRACT DOCUMENTS ARE EQUALLY BINDING ON ALL CONTRACTORS AND TRADES. EACH <br />CONTRACTOR IS REQUIRED TO KEEP FULL SETS OF THE CONTRACT DOCUMENTS FOR HIS/HERS <br />EMPLOYEES USE ON THE PROJECT TO ASSURE THAT ALL WORK IS PROPERLY COORDINATED AND <br />INSTALLED WITH THE WORK OF OTHER CONTRACTORS AND TRADES. <br />8. CONTRACTORS SHALL MEET WITH THE ARCHITECT PRIOR TO CONSTRUCTION OF THE PROJECT TO <br />REVIEW ALL EXISTING CONDITIONS AND THE EXACT EXTENT OF THE WORK TO BE COMPLETED. <br />9. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2018 NC BUILDING CODE AND ALL OTHER LOCAL <br />CODES AND REGULATIONS HAVING JURISDICTION. <br />10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING <br />CONSTRUCTION AROUND THE SITE WHICH WILL REMAIN. ANY DAMAGES SHALL BE REPAIRED TO <br />THE OWNER'S SATISFACTION AT NO COST. <br />11. SLOPE ALL EXTERIOR LANDINGS, WALKS, PORCHES, STEPS, ETC. 1/8" : 12" AWAY FROM THE <br />BUILDING FOR DRAINAGE UNLESS NOTED OR SHOWN OTHERWISE. <br />12. FRAMING LUMBER IN CONTACT WITH MASONRY, CONCRETE OR STEEL SHALL BE PRESSURE <br />TREATED. <br />13. GENERAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS LOOSE STEEL LINTELS AS REQUIRED <br />WHERE MECHANICAL, PLUMBING OR ELECTRICAL EQUIPMENT PASS THRU WALLS OR OVER ANY <br />BUILT-IN ITEMS IN MASONRY WALLS. <br />14. SLOPE FLOOR TO FLOOR DRAINS. COORDINATE ALL FLOOR DRAINS WITH PLUMBING CONTRACTOR. <br />15. PROVIDE WEEP HOLES @ 16" O.C. OVER ALL MASONRY OPENINGS. <br />16. PROVIDE FIRE TREATED LUMBER AS REQUIRED BY THE BUILDING CODE. <br />17. FIRE PENETRATION NOTES APPLY TO ALL TRADES. <br />18. PROVIDE BLOCKING IN METAL STUD WALLS AS REQUIRED FOR ALL SUSPENDED ITEMS INCLUDING <br />BUT NOT LIMITED TO E.W.C., TOILET ACCESSORIES, PLUMBING, MECHANICAL, ELECTRICAL & ETC. - <br />COORDINATE WITH OTHER TRADES. <br />19. SEE ELEVATIONS FOR EXTERIOR WALL MASONRY CONTROL JOINTS (CJ) LOCATIONS. CONTROL <br />JOINTS TO BE IN MASONRY JOINTS. LOCATE WALL CONTROL JOINTS AS INDICATED. <br />20. FURR WALLS AS REQUIRED FOR MECHANICAL AND PLUMBING VENTS. <br />21. DO NOT CUT ANY LAY-IN ACOUSTICAL CEILING PANELS LESS THAN 6" UNLESS INSTRUCTED BY THE <br />ARCHITECT. LAY-IN CEILING PANELS TO BE EQUALLY SPACED IN AREA. <br />22. DIMENSIONS SHOWN ON FLOOR PLANS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE (SEE <br />FLOOR PLAN NOTES ON SHEET 4.10). <br />23. UNLESS NOTED OTHERWISE, CARRY ALL FIRE RATED WALLS AND PARTITIONS TO STRUCTURE <br />ABOVE. <br />24. NO CORE OF BLOCKS SHOULD BE EXPOSED. USE SOLID BLOCK WHERE REQUIRED TO KEEP CORES <br />FROM BEING VISIBLY EXPOSED. <br />25. WALL TO TERMINATE 12" ABOVE HIGHEST ADJACENT CEILING U.N.O. <br />26. THERE SHALL BE NO EXPOSED CONDUIT ON THE EXPOSED CMU OR ANY OTHER WALLS. <br />Project No. <br />Sheet No. <br />ALL NOTES APPLY TO ALL DRAWINGS AND ALL TRADES. IT IS THE RESPONSIBILITY OF ALL CONTRACTORS AND <br />TRADES TO COORDINATE THE INSTALLATION OF THEIR WORK WITH THE INSTALLATION OF WORK BY ALL OTHER <br />CONTRACTORS AND TRADES. THE REQUIREMENTS OF THE DRAWINGS, GENERAL REQUIREMENTS AND ALL ITEMS <br />OF THE CONTRACT DOCUMENTS ARE EQUALLY BINDING ON ALL CONTRACTORS AND TRADES. EACH <br />CONTRACTOR IS REQUIRED TO MAINTAIN FULL SETS OF THE CONTRACT DOCUMENTS FOR HIS EMPLOYEES USE <br />ON THE PROJECT TO ASSURE THAT ALL WORK IS PROPERLY COORDINATED AND INSTALLED WITH THE WORK OF <br />OTHER CONTRACTORS AND TRADES. <br />WHENEVER THERE ARE DISCREPANCIES BETWEEN DRAWINGS, OR BETWEEN THE DRAWINGS AND <br />SPECIFICATIONS, OR CONFLICTS WITHIN THE SPECIFICATIONS AND/OR DRAWINGS, AND SUCH DISCREPANCY IS <br />NOT CALLED TO THE ARCHITECT'S ATTENTION IN TIME TO PERMIT CLARIFICATION BY ADDENDUM, THE <br />CONTRACTOR SHALL BASE HIS BID UPON PROVIDING THE BETTER QUALITY OR GREATER OF WORK OR MATERIAL <br />CALLED FOR, SHALL SUBMIT A WRITTEN STATEMENT WITH HIS PROPOSAL NOTING SUCH DISCREPANCIES, AND <br />SHALL SO FURNISH AND INSTALL SUCH BETTER QUALITY OR GREATER QUANTITY UNLESS OTHERWISE ORDERED <br />IN WRITING. <br />GENERAL NOTE <br />Date: <br />Drawn by: <br />Checked by: <br />Revisions: <br />AJP/GAS <br />JRS/GAS <br />1.800.671.0621www.scn-architects.com719 East Second AvenueGastonia, NC 28054Phone: 704.865.6311Fax: 704.865.00461637 <br />4.11NEW EMS STATION #4 & MEDICALEXAMINER'S QUARTERS FOR ORANGECOUNTYFLOOR PLAN NOTES3800 US HWY 70 EFLAND, NC 2724312/31/2021 <br />12/31/2021 <br />1/8" = 1'-0"1 FLOOR PLAN NOTES <br />PLAN <br />NORTH <br />DocuSign Envelope ID: 69D65917-B03B-48EF-AB90-57368B9A583E