Browse
Search
2022-286-E-AMS-Owens Roofing-Whitted complex roof replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2022
>
2022-286-E-AMS-Owens Roofing-Whitted complex roof replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/19/2022 1:40:40 PM
Creation date
7/19/2022 1:37:26 PM
Metadata
Fields
Template:
Contract
Date
7/6/2022
Contract Starting Date
7/6/2022
Contract Ending Date
7/19/2022
Contract Document Type
Contract
Amount
$896,317.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
290
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />221423.3 – ROOF DRAINS <br /> <br />Project Manual for Whitted Building Roof Replacement <br />Orange County, Hillsborough, NC <br />Prepared by Atlas Engineering, Inc., 551-A Pylon Drive – Raleigh, NC 27606 <br />May 2022 <br /> <br />K. Fire Rated Sealant: Shall be a fire rated sealant to meet UL requirement to maintain existing firewall <br />rating. Similar to AC-20 FTR as manufactured by Pecora. To be used in conjunction with fire blocking <br />material. <br /> <br />L. Miscellaneous: Cast iron drain extension rings, domes, clamping rings. <br /> <br />PART 3 EXECUTION <br /> <br />3.01 INSTALLATION-GENERAL <br /> <br />A. Frame the deck opening for the new drain. <br /> <br />B. Core the existing wood roof deck to allow for installation of a new vertical drain line (Primary - 3″ <br />I.D., Secondary – 4″ I.D.), and transition to a (Primary - 3″ I.D., Secondary – 4″ I.D.), horizontal <br />drain line within the existing attic space. Core through the existing exterior masonry wall to allow <br />for the horizontal drain line to run from the interior attic space out to a copper conductor head and <br />downspout. <br /> <br />C. Contractor shall install pipes and accessories (Install drain bowl as required). Contractor shall be <br />responsible for cutting and repairing deck or gypsum ceiling. <br /> <br />D. Dimensions and locations on plans are approximations and should be field-verified by the Contractor <br />before proceeding with work. <br /> <br />E. Install new pipe and drains in accordance with membrane manufacturer's recommendations and detail <br />drawings. <br /> <br />F. Obtain hot work permit as applicable. <br /> <br />3.02 DRAINS AND PIPE <br /> <br />A. Install new pipes at location shown on the drawings. <br /> <br />B. If required, install new steel angle to support drain bowl in accordance with the American Institute of <br />Steel Construction (AISC) Specification for the Design, Fabrication and Erection of Structural Steel <br />for Buildings and Bridges (latest edition), hereinafter referred to as the AISC Specification, and the <br />AISC Code of Standard Practice for Steel Buildings and Bridges (latest edition) shall govern the <br />work. Welding shall be in accordance with American Welding Society (AWS) Structural Welding <br />Code - Steel, D1.1-84, hereinafter referred to as the AWS Code. High-strength bolting shall be in <br />accordance with Research Council on Structural Connections (RCSC) Specifications for Structural <br />Joints Using ASTM A 325 or A 490 Bolts (latest edition). <br /> <br />C. Support drain piping with pipe hangers spaced at 10 feet maximum; provide minimum of two hangers <br />per length of pipe. All piping shall be installed to provide required minimum positive slope for <br />drainage. <br /> <br />DocuSign Envelope ID: 89558C18-938A-4BFF-B14A-A2214E8AA5DD