Orange County NC Website
ORANGE COUNTY 015000-3 <br /> <br />Emergency Management Warehouse Building Dehumidification Temporary Facilities and Controls <br /> <br /> <br />Provide and maintain portable, UL rated; with class and extinguishing agent as required by locations and classes of 1 <br />fire exposures. Comply with NFPA 10 Standard for Portable Fire Extinguishers. Locate fire extinguishers where con-2 <br />venient and effective for their intended purpose, but not less than one extinguisher on each floor or area at or near 3 <br />each usable stairwell. 4 <br /> 5 <br />Store combustible materials in containers in fire-safe locations. 6 <br /> 7 <br />Maintain unobstructed access to fire extinguishers, fire hydrants, temporary fire-protection facilities, stairways, and 8 <br />other access routes for fighting fires. 9 <br /> 10 <br /> 11 <br />SECURITY AND SAFETY DURING CONSTRUCTION 12 <br /> 13 <br />Barricades, Warning Signs, and Lights: Comply with requirements of authorities having jurisdiction for erecting struc-14 <br />turally adequate barricades, including warning signs and lighting. 15 <br /> 16 <br />Temporary Egress: Maintain temporary egress from existing occupied facilities as indicated and as required by au-17 <br />thorities having jurisdiction. 18 <br /> 19 <br />Temporary Enclosures: Provide temporary enclosures for protection of construction, in progress and completed, from 20 <br />exposure, foul weather, other construction operations, and similar activities. Provide temporary weathertight enclo-21 <br />sure for building exterior. Where heating or cooling is needed and permanent enclosure is incomplete, insulate tem-22 <br />porary enclosures. 23 <br /> 24 <br /> 25 <br />MOISTURE AND MOLD CONTROL DURING CONSTRUCTION 26 <br /> 27 <br />Exposed Construction Phase: Before installation of weather barriers, when materials are subject to wetting and ex-28 <br />posure and to airborne mold spores, protect as follows: 29 <br /> 30 <br />Protect porous materials from water damage. 31 <br /> 32 <br />Protect stored and installed material from flowing or standing water. 33 <br />Keep porous and organic materials from coming into prolonged contact with concrete. 34 <br /> 35 <br />Keep roof, wall, and/or openings covered or dammed. 36 <br /> 37 <br />Partially Enclosed Construction Phase: After installation of weather barriers, but before full enclosure and condition-38 <br />ing of building, when installed materials are still subject to infiltration of moisture and ambient mold spores, protect as 39 <br />follows: 40 <br /> 41 <br />Do not load or install porous materials or components, or items with high organic content, into partially en-42 <br />closed building. 43 <br /> 44 <br />Keep interior spaces reasonably clean and protected from water damage. 45 <br /> 46 <br />Periodically collect and remove waste containing cellulose or other organic matter. 47 <br /> 48 <br />Discard or replace water-damaged material. 49 <br /> 50 <br />Do not install material that is wet. 51 <br /> 52 <br />Discard, replace, or clean stored or installed material that begins to grow mold. 53 <br /> 54 <br />Perform work in a sequence that allows any wet materials adequate time to dry before enclosing the materi-55 <br />al in drywall or other interior finishes. 56 <br /> 57 <br />Controlled Construction Phase of Construction: After completing and sealing of the building enclosure, maintain as 58 <br />follows: 59 <br /> 60 <br />Control moisture and humidity inside building by maintaining effective dry-in conditions. 61 <br />62 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951