Orange County NC Website
WALL SENSORS (T'STAT, H'STAT, ETC).WHERE FEASIBLE, COMBINE MULTIPLE DEVICES IN COMMON ENCLOSURES.LIGHTING CONTROL SWITCH(ES) PROVIDED UNDER DIVISION 26FLOORDOOR JAMB(HINGE SIDE)CLCLSW DETAIL: CL11NOTE: IF SENSORS HAVE SETPOINT ADJUSTMENT, MOUNT AT 48" AFF TO MEET FRONT WHEELCHAIR ADA ACCESS REQUIREMENTS.12" JSTARTERMOTOR CONTROL CENTER (MCC)SWITCHBOARD OR PANELBOARDVFDKEYED NOTES:SW DETAIL: MR011141010510107623831110291012345678910EQUIPMENT FURNISHED AND INSTALLED BY CONTRACTOR. CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS.CONDUIT & WIRING BY DIVISION 26 CONTRACTOR.PROVIDE DISCONNECT AND FUSING.PROVIDE ADDITIONAL DISCONNECT IF REQUIRED BY NEC.A COMBINATION STARTER MAY BE USED IN LIEU OF A SEPARATE DISCONNECT SWITCH AND STARTER.POWER DISTRIBUTION EQUIPMENT BY DIVISION 26 CONTRACTOR.JUNCTION BOX REQUIRED BY THE DIVISION 26 CONTRACTOR FOR EQUIPMENT IF NO STARTER IS REQUIRED. PROVIDE MOTOR-RATED DISCONNECT SWITCH WHERE REQUIRED BY CODE. THE DIVISION 26 CONTRACTOR SHALL PROVIDE LINE SIDE WIRING TO THE DISCONNECT. PROVIDE LOAD SIDE WIRING.PROVIDE VARIABLE FREQUENCY DRIVE (VFD) WHERE NECESSARY.FOR PROJECTS UTILIZING A MOTOR CONTROL CENTER (MCC), THE STARTER, CIRCUIT BREAKER OR VFD IN THE MCC SHALL BE PROVIDED BY THE DIVISION 26 CONTRACTOR.PROVIDE RACEWAY & WIRING IN ACCORDANCE WITH REQUIREMENTS FOR RACEWAYS AND WIRING METHODS IN DIVISION 26 SPECIFICATIONS.NOTE: COORDINATE FAN LOCATION WITH MANUFACTURER'S RECOMMENDATIONS FOR CLEARANCES TO ADJACENT EQUIPMENT, ETC.WINGLET BLADEEND CAP (TYPICAL)SUPPORT MECHANISM BY FAN MFG. PROVIDE STRUCTURAL SUPPORT DRAWINGS SEALED BY A LICENSED ENGINEER.MOTORSECONDARY SAFETY SUPPORT CABLE (TYPICAL)FAN HUBSAFETY STRAP INTERIOR TO BLADE ANCHORED BETWEEN WINGLET & HUB.AIR FOIL BLADE. SEE SCHEDULE FOR BLADE QUANTITY & FAN DIAMETERTABLE A - WORKING CLEARANCESSTRUCTURAL CEILINGSUSPENDED CEILINGLIGHT FIXTUREWALLELECTRICAL EQUIPMENTPLANE OF FRONT EDGE OF ELECTRICAL EQUIPMENTDEDICATED WORKING SPACEVOLTAGE TO GROUND NOMINAL CONDITIONSEE TABLE 'A'THIS DISTANCE30" MIN.OR WIDTH OF EQUIPMENTMINIMUM CLEAR DISTANCE (FEET)0-150151-6001 233 3333 1/246'-6" MIN.WHERE THE CONDITIONS ARE AS FOLLOWS:1. EXPOSED LIVE PARTS ON ONE SIDE AND NO LIVE OR UNGROUNDED PARTS ON THE OTHER SIDE OF THE WORKING SPACE, OR EXPOSED LIVE PARTS ON BOTH SIDES EFFECTIVELY GUARDED BY SUITABLE WOOD OR OTHER INSULATING MATERIALS. INSULATED WIRE OR INSULATED BUSBARS OPERATING AT NOT OVER 300V SHALL NOT BE CONSIDERED LIVE PARTS.2. EXPOSED LIVE PARTS ON ONE SIDE AND GROUNDED PARTS ON THE OTHER SIDE.3. EXPOSED LIVE PARTS ON BOTH SIDES OF THE WORK SPACE (NOT GUARDED AS PROVIDED IN CONDITION 1), WITH THE OPERATOR BETWEEN.FIGURE 1FIGURE 2NOTES:1. THESE FIGURES ILLUSTRATE THE WORKING CLEARANCE AND DEDICATED SPACE AROUND ELECTRICAL EQUIPMENT AS REQUIRED BY NEC SECTION 110-26.2. DEDICATED SPACE RUNS TO A HEIGHT OF 6'-0" ABOVE EQUIPMENT. DEDICATED SPACE CONTINUES THROUGH SUSPENDED CEILING OR UP TO STRUCTURAL CEILING. ANY FOREIGN SYSTEMS TO THE ELECTRICAL EQUIPMENT SHALL NOT RUN WITHIN THIS SPACE. (FIGURE 2)STRUCTURAL CEILINGSUSPENDED CEILINGLIGHT FIXTUREWALLELECTRICAL EQUIPMENTDEDICATED SPACESW DETAIL: MR03TRAPNOSUPPORT CHANNEL (TYP)DEHUMIDIFICATION UNIT3/4" CONDENSATE DRAINHANGER ROD w/VIBRATION ISOLATOR TO STRUCTURE (TYP) (DO NOT BLOCK ACCESS DOORS)HANGER ROD TO STRUCTURE (TYP) Sheet Title:Sheet Number:Revisions:Designed by: Checked by:Date:Project Number:Copyright © 2021 Salas O'BrienSO Project No: ORANGE COUNTYEMERGENCY SERVICES CENTERDEHUMIDIFICATION510 MEADOWLANDS DRIVEHILLSBOROUGH, NORTH CAROLINA0611-02-00-2001/14/2022DETAILSH2010611-02-00-20GTB AFSSCALE:NTSH2013SPACE THERMOSTAT/SENSOR INSTALLATIONSCALE:NTSH2014ELECTRICAL CONNECTIONS TO EQUIPMENTSCALE:NTSH2015HIGH VOLUME LOW SPEED FAN DETAILSCALE:NTSH2016CLEARANCES FOR ELECTRICAL EQUIPMENTSCALE:NTSH2011HORIZONTAL DEHUMIDIFICATION UNITDocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951