Orange County NC Website
ORANGE COUNTY 262726-2 <br /> <br />Emergency Management Warehouse Building Dehumidification Wiring Devices <br /> <br /> <br /> <br />Receptacles: 1 <br /> 2 <br />General-Use Duplex: Provide duplex specification grade type receptacle, 2-pole, 3-wire, grounding, with 3 <br />green hexagonal equipment ground screw, high impact nylon face, ground terminal, brass triple wipe 4 <br />contacts, 20 Ampere rated, 125-volts, with metal plaster ears. Provide receptacles with grounding terminal 5 <br />internally connected to mounting yoke. Receptacles shall be designed for side and back wiring with spring-6 <br />loaded, screw activated pressure plates, with NEMA configuration 5-20R unless otherwise indicated. 7 <br /> 8 <br />General-Use Simplex: Provide single specification grade type receptacle, 2-pole, 3-wire, grounding, with 9 <br />green hexagonal equipment ground screw, high impact nylon face, ground terminal, brass triple wipe 10 <br />contacts, 20 Ampere rated, 125 volts, with metal plaster ears. Provide receptacles with grounding terminal 11 <br />internally connected to mounting yoke. Receptacles shall be designed for side and back wiring with spring-12 <br />loaded, screw activated pressure plates, with NEMA configuration 5-20R unless otherwise indicated. 13 <br /> 14 <br />Ground-Fault Interrupter: Provide specification grade ground-fault circuit interrupter, with heavy-duty duplex 15 <br />receptacles capable of being installed in a 1-1/2" deep outlet box without adapter. Ground fault interrupter 16 <br />receptacles shall be grounding type, UL Class A, Group 1, 20 ampere rated, 120-volts, 60 Hz, with high 17 <br />impact nylon face, brass triple wipe contacts, and solid-state ground-fault sensing and signaling. Devices 18 <br />shall have 5 milliamperes ground-fault trip level and shall be equipped with NEMA configuration 5-20R. 19 <br /> 20 <br />Special Receptacles: Provide special receptacles with NEMA configuration, voltage rating, current rating, 21 <br />and other attributes as indicated on the Drawings in Receptacle Schedules, General Notes, Keyed Notes, or 22 <br />other designations. 23 <br /> 24 <br />Receptacles provided are to be either straight blade, locking type, or pin type as indicated. All 25 <br />receptacles are to be equipped with green hexagonal equipment ground screw, brass triple wipe 26 <br />contacts and brass connector screws. 27 <br /> 28 <br />Receptacles shall be designed for both side and back wiring with spring-loaded and screw 29 <br />activated pressure plates where such are available in the device type indicated. 30 <br /> 31 <br />Miscellaneous Features: 32 <br /> 33 <br />Provide the following additional receptacle features where such is required by code or indicated on the 34 <br />drawings: 35 <br /> 36 <br />Weather resistant (WR) for all general use and ground fault interrupter receptacles installed in 37 <br />damp and wet locations. 38 <br /> 39 <br />Switches: 40 <br /> 41 <br />Snap: Provide heavy-duty, specification grade, flush single-pole AC quiet toggle switches, 20 Amperes, 42 <br />120-277 Volts AC, with silver cadmium oxide contacts, brass terminal screws, and mounting yoke insulated 43 <br />from mechanism. Equip switches with plaster ears, switch handle, and green hexagonal equipment 44 <br />grounding screw. Switches shall be designed for side and back wiring with spring-loaded, screw activated 45 <br />pressure plates. 46 <br /> 47 <br /> 48 <br />WIRING DEVICE ACCESSORIES 49 <br /> 50 <br />Wallplates for Flush Mounted Devices: Provide standard sized stainless steel (Type 302 wallplates for flush mounted 51 <br />single and combination wiring devices of types, sizes, and with ganging and cutouts as required for the application. 52 <br />Select plates that mate and match wiring devices to which attached; provide blank plates for empty or unused boxes. 53 <br />Provide screws for securing plates to devices; screw heads shall match finish of plates. Oversized plate shall not be 54 <br />used unless specifically permitted by the A-E. A quantity of 2% spare plates shall be provided for the Owner. 55 <br /> 56 <br />Wallplates for Surface Mounted Devices: Provide steel plates as required to match device box construction. 57 <br /> 58 <br />Wallplates for exterior and/or wet locations: Provide weatherproof PVC products listed as "extra duty while in use." 59 <br />Covers shall be rectangular, transparent high-impact, UV-resistant polycarbonate. 60 <br />61 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951