Browse
Search
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2022
>
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2022 1:08:32 PM
Creation date
4/6/2022 1:04:33 PM
Metadata
Fields
Template:
Contract
Date
4/6/2022
Contract Starting Date
4/6/2022
Contract Ending Date
4/6/2022
Contract Document Type
Contract
Amount
$185,662.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
226
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORANGE COUNTY 260519-1 <br /> <br />Emergency Management Warehouse Building Dehumidification Secondary Voltage Wires and Cables <br /> <br /> <br /> <br />SECTION 260519 - SECONDARY VOLTAGE WIRES AND CABLES 1 <br /> 2 <br />PART 1 - GENERAL 3 <br /> 4 <br />RELATED DOCUMENTS 5 <br /> 6 <br />Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 7 <br />Specification sections, apply to work of this section. 8 <br /> 9 <br /> 10 <br />QUALITY ASSURANCE 11 <br /> 12 <br />Manufacturers: Firms regularly engaged in manufacture of electrical products, of types and ratings required in this 13 <br />Section, whose products are Listed and Labeled for the purpose intended. Subject to compliance with requirements 14 <br />provide devices equivalent to one of the following: 15 <br /> 16 <br />Encore Wire Corporation 17 <br />General Cable Corporation 18 <br />Southwire Company 19 <br />Cerro Wire 20 <br /> 21 <br />Codes and Standards: 22 <br /> 23 <br />NEC Compliance: Comply with NEC requirements as applicable to construction, installation and color 24 <br />coding of electrical wires and cables. 25 <br /> 26 <br />Testing Laboratory Compliance: Provide wiring/cabling and connector products that are Listed and Labeled. 27 <br /> 28 <br /> 29 <br />SUBMITTALS 30 <br /> 31 <br />Submittals shall be made in strict accordance with the requirements of Section 019913. Specific submittal 32 <br />requirements are defined in each section of this Division. 33 <br /> 34 <br />Product Data: Submit manufacturer's data on electrical wires, cables and connectors. 35 <br /> 36 <br /> 37 <br /> PART 2 - PRODUCTS 38 <br /> 39 <br /> 40 <br />SECONDARY VOLTAGE WIRES, CABLES, AND CONNECTORS 41 <br /> 42 <br />General: Provide electrical wires, cables, and connectors of manufacturer's standard materials, as indicated by 43 <br />published product information. Connections shall be designed and constructed using connectors as recommended by 44 <br />manufacturer for a complete installation for the application indicated. Provide copper conductors with conductivity of 45 <br />not less than 98% at 68 F. 46 <br /> 47 <br />Building Wires: Provide factory-fabricated wires of sizes, ampacity ratings, and materials for applications and 48 <br />services indicated. Where not indicated, provide proper wire selection as determined by Contractor to comply with 49 <br />project's installation requirements, NEC and NEMA standards. Select from the following Listed types those wires with 50 <br />construction features that fulfill project requirements: 51 <br /> 52 <br />Type THWN/THHN: For general use as interior branch circuits and feeders; maximum operating 53 <br />temperature 90 C (194 F). Insulation, flame-retardant, moisture- and heat-resistant, thermoplastic; outer 54 <br />covering, nylon jacket; conductor, annealed copper. 55 <br /> 56 <br />Type XHHW: For general use as exterior feeders and service entrance conductors, as conductors in all 57 <br />underground raceway, as conductors in wet locations and as specifically indicated on the Drawings; 58 <br />maximum operating temperature 90 C (194 F). Insulation, moisture and heat-resistant cross-linked 59 <br />polymer; conductor, annealed copper. 60 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951