Browse
Search
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2022
>
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2022 1:08:32 PM
Creation date
4/6/2022 1:04:33 PM
Metadata
Fields
Template:
Contract
Date
4/6/2022
Contract Starting Date
4/6/2022
Contract Ending Date
4/6/2022
Contract Document Type
Contract
Amount
$185,662.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
226
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORANGE COUNTY 260500-7 <br /> <br />Emergency Management Warehouse Building Dehumidification Basic Electrical Requirements <br /> <br /> <br /> <br />Control wiring shall be installed in raceways and box system separate from power wiring, unless otherwise indicated 1 <br />on Drawings. Wiring within equipment enclosures shall be in raceways provided under this section of the 2 <br />Specifications unless approved raceway is provided by the manufacturer of the equipment or unless the equipment is 3 <br />listed for use as a raceway. 4 <br /> 5 <br /> 6 <br />ELECTRICAL PROVISIONS FOR DIVISIONS 21 - 23 7 <br /> 8 <br />Division 26 Contractor shall provide complete power wiring to a disconnecting means provided under Division 9 <br />supplying the equipment. Extension of power from the disconnecting means to the utilization equipment shall be 10 <br />made under the Division supplying the equipment. 11 <br /> 12 <br />Starters, contactors, and similar control equipment shall be furnished and installed by other divisions unless 13 <br />specifically shown on the electrical Drawings. Control wiring is furnished by the Division supplying the control 14 <br />equipment. 15 <br /> 16 <br />Fuses for fused disconnects are furnished and installed by the division supplying the equipment to be protected. 17 <br /> 18 <br />Refer to 230511, ELECTRICAL PROVISIONS FOR HVAC WORK for a complete description and breakdown of the 19 <br />responsibility of each trade (Divisions 23 and Divisions 26). 20 <br /> 21 <br /> 22 <br />END OF SECTION 260500 23 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951