Browse
Search
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2022
>
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2022 1:08:32 PM
Creation date
4/6/2022 1:04:33 PM
Metadata
Fields
Template:
Contract
Date
4/6/2022
Contract Starting Date
4/6/2022
Contract Ending Date
4/6/2022
Contract Document Type
Contract
Amount
$185,662.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
226
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORANGE COUNTY 233423 - 2 <br /> <br />Emergency Management Warehouse Building Dehumidification HVAC Power Ventilators <br /> <br /> <br />POWER VENTILATORS 1 <br /> 2 <br />HVLS Fan: Provide high velocity, low speed fan suspended from building structure, size capacity, and arrangement 3 <br />as indicated on the Drawings and as specified herin. 4 <br /> 5 <br />The fan shall be ETL certified and built pursuant to construction guidelines set forth by UL standards 507 6 <br />and CSA standard C22.2 No. 113-08. The fan shall be designed to move an effective amount of air for 7 <br />cooling and destratification, commercial applications. The fan, in operation, shall not disturb other hanging 8 <br />objects 2’ (61 cm) outside of its circumference to a distance of 3’ (91 cm) below its airfoils. The fan shall 9 <br />incorporate a direct drive system designed specifically for high volume, low speed fans to ensure silent 10 <br />operation. The sound levels from the fan operating at maximum speed shall not exceed 40 dBA (measured 11 <br />20’ (6.1 cm) below the blades and 20’ (6.1 cm) horizontally from the center of the fan). 12 <br /> 13 <br />The fan shall be equipped with ten (10) high volume, low speed airfoils of precision extruded aluminum alloy. 14 <br />Each airfoil shall be of the high performance. The airfoils shall be connected by means of two (2) sets of 15 <br />bolts and lock washers per airfoil. The airfoils shall be connected to the hub and interlocked with zinc plated 16 <br />steel retainers. 17 <br /> 18 <br />The fan shall be equipped with ten (10 winglets designed to redirect outward airflow into downward airflow, 19 <br />thereby enhancing the efficiency and effectiveness of the fan. The winglets shall be molded thermoplastic 20 <br />polyester resin. A winglet shall be attached at the tip of each airfoil. Winglets shall be powder coated to 21 <br />match architects color sample. 22 <br /> 23 <br />The fan motor shall be a permanent magnet brushless motor rated for continuous operation at maximum 24 <br />speed with the capability of modulating the fan speed from 0-100% without the use of a gearbox or other 25 <br />mechanical means of control. The motor shall operate from any voltage ranging from 100-130 VAC, 1 φ, and 26 <br />60Hz, without requiring adapters or customer selection. The motor shall be a non-ventilated, heat sink 27 <br />design. 28 <br /> 29 <br />The fan hub shall be constructed of steel for high strength and durability. The hub shall be precision 30 <br />machined to achieve a well balanced and solid rotating assembly. The hub shall incorporate five (5) safety 31 <br />retaining clips made of 1/8” (0.3 cm) thick steel that shall restrain the hub/airfoil assembly in case of shaft 32 <br />failure. 33 <br /> 34 <br />The fan mounting system shall be designed for quick and secure installation from the structure. All 35 <br />components in the mounting system shall be of welded construction using low carbon steel no less than 36 <br />3/16” (0.5 cm) thick and powder coated or plated for corrosion resistance and appearance. All mounting 37 <br />bolts shall be SAE Grade 8 or equivalent. 38 <br /> 39 <br />The fan shall be equipped with a safety cable that provides an additional means of securing the fan 40 <br />assembly to the building structure. The safety cable shall be 3/16” (0.5 cm) diameter and fabricated out of 7 41 <br />x 19 stranded galvanized steel. The loops shall be secured with swaged Nicopress fittings, pre-loaded and 42 <br />tested to 3,000 lb·f. Field construction of safety cables is not permitted. 43 <br /> 44 <br />The fan controller shall be incorporated into the fan assembly. The controller shall be factory programmed to 45 <br />minimize starting and braking torques. The controller shall be equipped with a simple diagnostic program 46 <br />and an LED light to identify and relay faults in the system. The controller shall be housed in an enclosure 47 <br />independent of the motor to prevent overheating or electrical interference. 48 <br /> 49 <br />The fan shall be equipped with a remote wall control. The wall control shall be capable of mounting to a 50 <br />standard electrical box and shall include operator controls and display for controlling the fan’s power and 51 <br />speed. Communication with the fan drive and controller shall be by a standard (14 Ga/3 wire with ground), 52 <br />line voltage cable that is field installed and provided by the installer. 53 <br /> 54 <br />The manufacturer shall replace any products or components in accordance to the following schedule: 55 <br />Airfoils, Lifetime (Parts); Hub, Lifetime (Parts); Motor, 10 years (Parts); Controller, 10 years (Parts); and 56 <br />Labor, 1 year 57 <br /> 58 <br />Contractor shall submit structural support drawings sealed be licensed professional engineer. 59 <br />60 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951