Browse
Search
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2022
>
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2022 1:08:32 PM
Creation date
4/6/2022 1:04:33 PM
Metadata
Fields
Template:
Contract
Date
4/6/2022
Contract Starting Date
4/6/2022
Contract Ending Date
4/6/2022
Contract Document Type
Contract
Amount
$185,662.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
226
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORANGE COUNTY 230923-16 <br /> <br />Emergency Management Warehouse Building Dehumidification Extension of Existing Direct Digital <br /> Control System for HVAC <br /> <br />Software for checking input commands and issuing error messages. Enter various correct and incorrect 1 <br />commands. 2 <br /> 3 <br />System and point addressing check. Enter command to display I/O data. Verify all data points defined on 4 <br />the drawings and/or required by the specifications. 5 <br /> 6 <br />Start-stop or enable-disable of HVAC equipment or DDC system control points. Enter commands to 7 <br />start/stop selected HVAC equipment, and to disable and enable selected points. 8 <br /> 9 <br />Operator override/automatic mode. Enter command to change selected automatic control under DDC 10 <br />system to manual and vice versa. 11 <br /> 12 <br />Display format. Enter commands to display data and graphics on terminal and graphic display. Check 13 <br />display content for adequacy and clarity as specified. 14 <br /> 15 <br />Ability to modify, cancel and confirm operator’s commands. Verify by entering commands. 16 <br /> 17 <br />Set-point adjustment and limiting. Enter commands to adjust set points of controllers and range limits of 18 <br />the controlled media. Verify by display. Also enter commands to adjust set-points outside their range 19 <br />limits. DDC system shall display error messages. 20 <br /> 21 <br />System access and access level control. Try to log on to system with both incorrect and correct ID codes. 22 <br />Try to enter different commands with different access level of the operators. The responses of the DDC 23 <br />system shall be as specified. 24 <br /> 25 <br />Start/stop equipment. Enter command to start or stop selected equipment. Also reset time to initiate 26 <br />automatic mode. Verify responses by observation of equipment and DDC system display. 27 <br /> 28 <br />Change parameter of points. Enter commands to change parameters of selected points such as high and 29 <br />low limit alarms, scale factor, etc. to test the adequacy of software. 30 <br /> 31 <br />Verify graphic display of each HVAC system and component. Confirm that the graphic is in accordance with the 32 <br />design data and reviewed submittals, includes all data points required, displayed data is correct and in the 33 <br />correct format and units, and changes in point conditions or status are accurately updated. Evaluate the refresh 34 <br />rate of data display. 35 <br /> 36 <br />Verify report generation (status, profile, energy, etc.) by entering commands to generate reports such as all 37 <br />points, trend, total display of a system, timed display, and other specified reports. Examine the report content for 38 <br />general format, system/point code, time interval of reporting, point status/value/unit, energy amount/rate/unit, 39 <br />status of control and set time (manual or automatic), and other specification required information. 40 <br /> 41 <br />Check for proper operation of system status reports, including point status reviews which would include 42 <br />information such as points currently in alarm, points removed from alarm checking, points off of scan, 43 <br />etc. 44 <br /> 45 <br />Test alarm reporting by initiating alarm conditions of different points at different alarm levels in 46 <br />sequence to examine alarm reports. The reports shall show alarm location and device, alarm time, 47 <br />cause of alarm, current status of the point, etc. as required in the specifications. When alarm conditions 48 <br />are removed the printer shall print updated status report. Also verify audible alarm operations in 49 <br />accordance with specification requirements. Then initiate alarm conditions at different levels at the 50 <br />same time to check alarm priority. 51 <br /> 52 <br />Trending performance shall be tested by creating trend logs for each control sequence and monitoring the trend 53 <br />reports throughout the period that each control sequence is tested. 54 <br /> 55 <br />OWNER INSTRUCTION AND TRAINING 56 <br /> 57 <br />Provide Owner instruction and training in accordance with Section 019926. 58 <br /> 59 <br />END OF SECTION 230923 60 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951
The URL can be used to link to this page
Your browser does not support the video tag.