Browse
Search
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2022
>
2022-133-E-AMS-Warren Hay Mechanical Contractors-Emergency Services Warehouse Dehumidification
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2022 1:08:32 PM
Creation date
4/6/2022 1:04:33 PM
Metadata
Fields
Template:
Contract
Date
4/6/2022
Contract Starting Date
4/6/2022
Contract Ending Date
4/6/2022
Contract Document Type
Contract
Amount
$185,662.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
226
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORANGE COUNTY 230719-1 <br /> <br />Emergency Management Warehouse Building Dehumidification HVAC Piping Insulation <br /> <br /> <br />SECTION 230719 - HVAC PIPING INSULATION 1 <br /> 2 <br />PART 1 - GENERAL 3 <br /> 4 <br /> 5 <br />RELATED DOCUMENTS 6 <br /> 7 <br />Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 8 <br />Specification sections, apply to work of this section. 9 <br /> 10 <br /> 11 <br />QUALITY ASSURANCE 12 <br /> 13 <br />Flame/Smoke Ratings: Provide composite mechanical insulation (insulation, jackets, coverings, sealers, mastics and 14 <br />adhesives) with flame-spread index of 25 or less, and smoke-developed index of 50 or less, as tested by ASTM E 84 15 <br />(NFPA 225) method. 16 <br /> 17 <br />Exception: Outdoor mechanical insulation may have flame spread index of 75 and smoke developed index 18 <br />of 150. 19 <br /> 20 <br /> 21 <br />SUBMITTALS 22 <br /> 23 <br />General: Submittals shall demonstrate compliance with technical requirements by reference to each subsection of 24 <br />this specification. Where a submitted item does not comply fully with each and every requirement of the 25 <br />Specifications, the submittal shall clearly indicate such deviations. Identification requirements for non-complying 26 <br />features of items are very specific. See Section 019913 for exact requirements. 27 <br /> 28 <br />Manufacturer's Data: Submit manufacturer's technical product data and installation instructions for each type of 29 <br />mechanical insulation. Submit schedule showing manufacturer's product number, k-value, thickness, and furnished 30 <br />accessories for each mechanical system requiring insulation. 31 <br /> 32 <br />Samples: Submit, as requested by A-E, manufacturer's sample of each piping insulation type required. Affix label to 33 <br />sample completely describing product. 34 <br /> 35 <br /> 36 <br />PART 2 - PRODUCTS 37 <br /> 38 <br /> 39 <br />PIPING INSULATION MATERIALS 40 <br /> 41 <br />Closed Cell, Flexible Elastomeric Insulation: Flexible elastomeric, closed cell, thermal insulation in accordance with 42 <br />ASTM C534, Type I, preformed tubes, black in color, rated for piping temperatures to 220 degrees F. Insulation shall 43 <br />be AP/Armaflex or equivalent. 44 <br /> 45 <br /> 46 <br />PART 3 - EXECUTION 47 <br /> 48 <br /> 49 <br />Classification Type 3A Piping: Insulate the following cold HVAC piping systems: 50 <br /> 51 <br />Cooling coil condensate drain piping. 52 <br /> 53 <br />Condensate drain piping within mechanical equipment rooms, and chilled water air separators and 54 <br />compression/expansion tanks may be insulated with 1” thick flexible elastomeric insulation. 55 <br /> 56 <br /> 57 <br /> 58 <br /> 59 <br /> 60 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951
The URL can be used to link to this page
Your browser does not support the video tag.