ORANGE COUNTY 019916 - 2 <br /> <br />Emergency Management Warehouse Building Dehumidification Divisions 23 and 26 <br /> Work in Existing Buildings <br /> <br /> <br />Where construction or attendant work interrupts normal functions in any area, a schedule of work shall be submitted 1 <br />for approval of the Owner and after approval, strictly followed. Modification to existing work shall be done as 2 <br />required. All work shall be performed in such a manner as to prevent any interruption of any service or utility. Where 3 <br />it is necessary to interrupt service for demolition, cut-in, or changeover, the work shall be scheduled well in advance 4 <br />of the interruption and the interruption approved by the Owner. As required by the Owner, such work shall be done 5 <br />during night, weekends, holidays, or other off peak period as approved. 6 <br /> 7 <br />Existing piping, ductwork, raceway and wiring, etc., shall be modified as indicated on the Drawings and/or as required 8 <br />by new and modified construction. Existing piping, ductwork, raceway and wiring, etc., shall be modified as required 9 <br />and put in first class operating condition. No equipment shall be disconnected without approval of the Owner's 10 <br />Representative. Temporary relocation of equipment and temporary piping, ductwork, wiring and raceway, etc., 11 <br />required for continued operation of the facility shall be provided as required. 12 <br /> 13 <br /> 14 <br />PART 3 - EXECUTION 15 <br /> 16 <br /> 17 <br />PERFORMANCE REQUIREMENTS 18 <br /> 19 <br />Comply with governing EPA notification regulations before beginning selective demolition. 20 <br /> 21 <br />Comply with hauling and disposal regulations of authorities having jurisdiction. 22 <br /> 23 <br /> 24 <br />EXAMINATION AND PREPARATION 25 <br /> 26 <br />Verify that utilities have been disconnected and capped, valved off, or otherwise secured before starting demolition. 27 <br /> 28 <br />Survey existing conditions and correlate with requirements indicated to determine extent of selective demolition 29 <br />required. 30 <br /> 31 <br />When unanticipated mechanical, electrical, or structural elements that conflict with intended function or design are 32 <br />encountered, investigate and measure the nature and extent of conflict. Promptly submit a written report to the A/E. 33 <br /> 34 <br />Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent 35 <br />buildings and facilities to remain. As necessary, provide dust barriers, noise control, etc. to minimize impact of 36 <br />demolition on adjacent occupied areas. 37 <br /> 38 <br />Provide protection to ensure safe passage of people around demolition area and to and from occupied portions of 39 <br />building. 40 <br /> 41 <br />Provide temporary weather protection, during interval between demolition of existing construction on exterior surfaces 42 <br />and new construction, to prevent water leakage and damage to structure and interior areas. 43 <br /> 44 <br />Provide heating, cooling, dehumidification, and ventilation as necessary to protect the existing building materials and 45 <br />finishes during the demolition period. 46 <br /> 47 <br />Where existing plumbing, fire protection, HVAC, or electrical services in demolition areas must be shutdown, 48 <br />temporary plumbing, fire protection, heating, cooling, dehumidification, ventilation, lighting, and electrical power shall 49 <br />be provided as needed to maintain use of adjacent occupied areas that are negatively impacted by the shutdown. 50 <br /> 51 <br />Protect walls, ceilings, floors, and other existing finish work that are to remain or that are exposed during selective 52 <br />demolition operations. 53 <br /> 54 <br />Cover and protect furniture, furnishings, and equipment that have not been removed. 55 <br /> 56 <br />Provide and maintain shoring, bracing, and structural supports as required to preserve stability and prevent 57 <br />movement, settlement, or collapse of construction and finishes to remain, and to prevent unexpected or uncontrolled 58 <br />movement or collapse of construction being demolished. 59 <br />60 <br />DocuSign Envelope ID: 7668B866-6C26-485C-9A45-DAAB5D4BD951