SERVICE DISCONNECTS <br />NEUTRAL BUS <br />CONDUIT BONDING <br />GROUND BUS <br />GROUNDED SERVICE CONDUCTOR <br />UNDERGROUND SERVICE <br />ENTRANCE <br />GROUNDING ELECTRODE <br />CONDUCTOR <br />GROUNDING ELECTRODE 10' X 3/4 " <br />DRIVEN GROUND ROD' PROVIDE <br />ADDITIONAL GROUND ROD TO ACHIVE <br />GROUNDING RESISTANCE LESS THAN 25 <br />OHMS. <br />SERVICE EQUIPMENT <br />PHASE CONDUCTORS <br />UTILITY OWNED SERVICE <br />TRANSFORMER <br />BOND TO STEEL <br />SCALE: NTS1ELECTRICAL RISER DIAGRAM <br />480Y/277V, 3∅, <br />4W SERVICE <br />COORDINATE ELECTRICAL SERVICE WITH PIEDMONT ELECTRIC <br />#6 GND <br />BARE CU IN <br />3/4"C <br />3/4"X10' <br />GROUND <br />ROD <br />BOND TO <br />STRUCTURAL <br />STEEL <br />DISCONNECT <br />200A, 3P <br />FUSED @200A <br />SERVICE <br />480V <br />NEMA-3R <br />UTILITY <br />METER PANEL "MDP" <br />225A, 3PH,4W, <br />MLO <br />480Y/277V <br />22 KAIC <br />NEMA-3R <br />15 <br />PLC CONTROLLER <br />& ACCESSIBLE <br />DISCONNECT <br />WITH EQUIPMENT <br />(TYP.) <br />SCALE: NTS2ELECTRICAL SERVICE GROUNDING DETAILS <br />A <br />C <br />E <br />G <br />GFCI <br />N <br />P <br />PH <br />PNL <br />TYP <br />V <br />W <br />- AMPERES OR ABOVE COUNTER <br />- CONDUIT <br />- ELECTRICAL CONTRACTOR <br />- EQUIPMENT GROUNDING CONDUCTOR OR GROUND FAULT <br />CIRCUIT INTERRUPTER <br />GROUND FAULT CIRCUIT INTERRUPTER <br />- NEUTRAL CONDUCTOR <br />- POLE <br />- PHASE <br />- PANELBOARD <br />- TYPICAL <br />- VOLTS <br />- WATTS, WIRES <br />STANDARD ABBREVIATIONS <br />BRANCH CIRCUIT, OR FEEDER WIRING, RUN IN CONDUIT AND CIRCUIT <br />HOMERUN TO PANELBOARD INDICATED. SINGLE PHASE CIRCUIT SHALL <br />CONTAIN 1 #12 PHASE CONDUCTOR, 1 #12 NEUTRAL CONDUCTOR AND 1 <br />#12 GROUNDING CONDUCTOR IN 3/4" CONDUIT, MINIMUM. <br />CONDUCTORS LARGER THAN #12, AND CONDUIT LARGER THAN 3/4", <br />SHALL BE AS INDICATED. WHERE "MULTIPLE PHASED" ELECTRICAL LOADS <br />ARE REQUIRED, PROVIDE ADDITIONAL PHASE CONDUCTORS. MULTIPLE <br />SINGLE PHASE CONDUCTORS MAY BE GROUPED TOGETHER IN A COMMON <br />CONDUIT AS ALLOWED AND IN ACCORDANCE WITH THE NEC, AND/OR AT <br />THE CONTRACTOR'S DISCRETION. CONTRACTOR SHALL PROVIDE <br />ADDITIONAL "SWITCH LEG" CONDUCTORS, AS REQUIRED TO ACHIEVE <br />FIXTURE CONTROL INDICATED ON PLANS. NEUTRAL AND GROUNDING <br />CONDUCTORS SHALL BE SHARED IN ACCORDANCE WITH AND AS <br />ALLOWED BY THE NEC. <br />MOTOR STARTER DISCONNECTING MEANS (OR VFD) <br />ELECTRICAL LEGEND: <br />WEATHER PROOF <br />PANELBOARD, SEE PANELBOARD SCHEDULE <br />GROUND FAULT <br />DUPLEX RECEPTACLE, 120 VOLT, MOUNT @ 36" AFF TO THE <br />CENTER, UNO <br />AS SUFFIX TO RECEPTACLES: <br />PLC MOTOR CONTROLLER WITH ACCESSIBLE DISCONNECT <br />MOTOR <br />GENERAL NOTES <br />1. ALL WORK SHALL CONFORM TO THE LATEST NATIONAL <br />ELECTRICAL CODE, STATE CODE, & LOCAL AUTHORITY <br />REQUIREMENTS. <br />2. THE CONTRACTOR SHALL VISIT THE PREMISES AND <br />THOROUGHLY FAMILIARIZE HIMSELF WITH ALL DETAILS OF <br />THE WORK AND WORKING CONDITIONS. VERIFY ALL FIELD <br />CONDITIONS INCLUDING LOCATION OF UTILITY LINES AND <br />ADVISE THE ENGINEER OF ANY DISCREPANCY THAT MAY <br />PREVENT OR HINDER THE SPECIFIED WORK FROM BEING <br />COMPLETED. <br />3. PRIOR TO ACCOMPLISHING ANY WORK IN ANY AREA, ALL <br />WORK SHALL BE PLANNED AND COORDINATED WITH OTHER <br />TRADES AND THE OWNER. <br />4. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED <br />PERMITS AND ARRANGE INSPECTIONS NECESSARY FOR THE <br />INSTALLATION OF HIS WORK AND FURNISH THE ENGINEER <br />WITH CERTIFICATES OF INSPECTIONS FROM ALL <br />AUTHORITIES HAVING JURISDICTION. <br />5. PROPERLY SUPPORT ALL WORK AND EQUIPMENT <br />INSTALLED UNDER THIS CONTRACT. STUDY ALL DRAWINGS, <br />MANUFACTURER'S INSTRUCTIONS, AND CATALOG DATA TO <br />DETERMINE HOW EQUIPMENT ACCESSORIES, AND RELATED <br />ITEMS ARE TO BE SUPPORTED, MOUNTED, OR SUSPENDED. <br />PROVIDE ALL BOLTS, INSERTS, BRACKETS, STRUCTURAL <br />SUPPORTS, AND ACCESSORIES FOR PROPER SUPPORT OF <br />EQUIPMENT FURNISHED UNDER THIS CONTRACT. <br />6. PROVIDE GREEN EQUIPMENT GROUNDING CONDUCTOR <br />WITH ALL FEEDER AND BRANCH CIRCUITS. <br />7. THE CONTRACTOR SHALL USE DIMENSION PLANS FOR <br />EXACT DIMENSIONS INCLUDED ELSEWHERE IN BID SET. DO <br />NOT SCALE THESE PLANS. <br />8. ALL WORK SHALL BE PERFORMED BY A LICENSED <br />ELECTRICAL CONTRACTOR. <br />9. ALL ELECTRICAL EQUIPMENT SHALL BE UL LABELED <br />WHERE CATEGORY EXISTS FOR SUCH EQUIPMENT. OTHER <br />THIRD PARTY LABELS ACCEPTABLE TO THE LOCAL <br />INSPECTOR MAY BE USED. <br />10. THE CONTRACTOR FURNISHING ANY EQUIPMENT <br />AND/OR SYSTEMS SHALL BE FULLY RESPONSIBLE FOR <br />CONTROLS OF ITS EQUIPMENT INCLUDING ALL DESIGN, <br />DEVICES, WIRING, CONDUITS, COMMISSIONING THE <br />SYSTEM ETC. THE CONTRACTOR SHALL COORDINATE <br />WHAT'S WOULD BE EXPECTED BY THE OWNER DURING <br />BIDDING PERIOD AND INCLUDE THE COST IN HIS BID. <br />AS REQUIRED PER MFR. <br />EQUIPMENT DIMENSION <br />NO BOTTOM PANEL <br />PROVIDE <br />BITUMIOUS <br />COATING ON <br />PIPE EMBEDED <br />IN CONCRETE <br />3000 PSI <br />CONCRETE <br />3" GALVANIZED <br />STEEL PIPE <br />GALVANIZED <br />HARDWARE <br />4'-0"3'-0"AS REQUIRED PER MFR.EQUIPMENT DIMENSION2'-6" <br />1'-6" <br />RAINSHIELD <br />FABRICATED OF <br />1/8" ALUMINUM <br />WELD ALL JOINTS <br />CAP <br />12"6"SCALE: NTS3TYPICAL EQUIPMENT RACK DETAILS <br />TVSS <br />4-3/0, 1#6G <br />IN 2"C <br />COMPACTOR-1 <br />3#10,1#10G <br />IN 3/4"C <br />4-3/0 AWG <br />IN 2"C <br />4-3/0 AWG <br />IN 2"C <br />#6 GND <br />BARE CU IN <br />3/4"C <br />3#10,1#10G IN 3/4"C <br />START <br />E-STOP <br />REV. <br />LOAD CENTER <br />"LC-AB" <br />208/120V <br />1∅,3W <br />30A MCB <br />PANEL "LA" <br />100A, 3PH,4W, <br />100A MCB <br />208Y/120V <br />10 KAIC <br />NEMA-3RD <br />T <br />#6G <br />3#10,1#10G IN 3/4"C <br />3#10,1#10G IN 3/4"C <br />3#10,1#10G IN 3/4"C <br />3#10,1#10G IN 3/4"C <br />3#10,1#10G IN 3/4"C <br />15 <br />COMPACTOR-2 <br />3#10,1#10G <br />IN 3/4"C <br />START <br />E-STOP <br />REV. <br />LOAD CENTER <br />"LC-AB" <br />208/120V <br />1∅,3W <br />30A MCB 15 <br />COMPACTOR-3 <br />3#10,1#10G <br />IN 3/4"C <br />START <br />E-STOP <br />REV. <br />LOAD CENTER <br />"LC-AB" <br />208/120V <br />1∅,3W <br />30A MCB <br />PANEL "EX" <br />100A, 1PH,3W, <br />90A MCB <br />208Y/120V <br />10 KAIC <br />4#6, <br />1#10G <br />IN 1"C <br />4#2, <br />1#8G IN <br />1 1/2"C <br />F0R EXISTING <br />ATTENDANT BOOTH <br />ATTENDANT <br />BOOTH AT <br />COMPACTOR-1 <br />ATTENDANT <br />BOOTH AT <br />COMPACTOR-2 <br />ATTENDANT <br />BOOTH AT <br />COMPACTOR-3 <br />30KVA <br />480-208Y/120V <br />IN NEMA-3R ENCL <br />WEATHERED BY UTILITY COMPANY <br />PRIMARY <br />FEEDER <br />AND <br />CONDUIT <br />BY UTILITY <br />COMPANY <br />EXISTING HIGH VOLTAGE POWER LINES ACROSS <br />THE STREET; COORDINATE WITH UTILITY <br />COMPANY TO OBTAIN THE 480V, 3 PHASE POWER <br />3#8,1#10G IN 3/4"C <br />DISCONNECT SWITCH <br />MOTOR <br />PROPOSED OVERHEAD HIGH VOLTAGE <br />3-PHASE LINE BY UTILITY COMPANY <br />EXISTING UTILITY POLE OWNED <br />BY UTILITY COMPANY <br />UTILITY <br />COMPANY <br />SCOPE <br />ELECTRICAL <br />CONTRACTOR'S <br />SCOPE <br />NOTE THAT EXISTING ELECTRICAL SERVICE TO THE EXISTING <br />ATTENDANT BOOTH IS 240/120V, 1 PHASE, 3 WIRES. ONCE TEH <br />NEW SERVICE IS ESTABLISHED, THE EXISTING SERVICE SHALL BE <br />REMOVED AND EXISTING LOAD CENTER WILL BE FED FROM NEW <br />SERVICE AS SHOWN IN PANEL SCHEDULES. <br />CLUSTER OF <br />TRANSFORMERS BY <br />UTILITY COMPANY <br />MANUAL <br />TRANSFER <br />SWITCH <br />225A, 3P <br />480V <br />22 KAIC <br />NEMA-3R <br />4-3/0, <br />1#6G <br />IN 2"C <br />GENERATOR <br />150KVA <br />C.B. <br />3/4"X10' <br />GROUND <br />ROD <br />4-3/0, 1#6G <br />IN 2"C <br />#6G <br />BOND TWO <br />SERVICES <br />WITH #6G <br />20A,120V, G, WP <br />SERVICE <br />RECEPTACLE; <br />CKT- LA-12 <br />U:\Projects GTC\Year 2021 Projects\2021-002 High Rock Road Recycling\Drawings\Electrical Plan.dwg March 26, 2021 3:51:56 PMDESIGNED BY: <br />DRAWN BY: <br />CHECKED BY: <br />SCALE: <br />DATE: <br />PROJECT NUMBER: <br />REVISIONS <br />R00592-213N <br />03/26/2021HIGH ROCK ROAD WASTE AND RECYCLYING CENTERORANGE COUNTY, NORTH CAROLINAEngineering Surveying Environmental ServicesNCSU Centennial Campus930 Main Campus Drive, Suite 151Raleigh, NC 27606919-827-0864 Fax: 919-839-8138www.daa.comNC Firm License # C-0861Virginia Beach, VAHampton Roads, VAFayetteville, NCCharlottesville, VABlacksburg, VARichmond, VANorthern Virginia03-26-21 <br />GreenTech Consulting, Inc. <br />Voice . 919 . 608 . 2412 <br />Cary , N.C. 27511 <br />1155 Kildaire Farm Road, Suite 206 <br />Plumbing, Mechanical, Electrical Engineers <br />Sustainable & LEED Design Services <br />hsura@greentc.com <br /> <br /> <br />IGNE <br />N REE <br />SRT <br />NOPRO F E <br />H C <br />L <br />IL <br />S IO <br />N <br />A NAA RO <br />HE <br />MA N T C .SURAGREENTECH LICENSE # C-2720 <br />HCS <br />HCS <br />HCS <br />AS SHOWN <br />DocuSign Envelope ID: BBF56E0A-3618-497E-AA70-92F097E8F598