Browse
Search
2022-063-E-Solid Waste-Bar Construction Co., Inc-Renovation of High Rock Waste and Recycling Center
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2022
>
2022-063-E-Solid Waste-Bar Construction Co., Inc-Renovation of High Rock Waste and Recycling Center
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2022 8:24:51 AM
Creation date
2/15/2022 8:19:36 AM
Metadata
Fields
Template:
Contract
Date
2/11/2022
Contract Starting Date
2/11/2022
Contract Ending Date
2/14/2022
Contract Document Type
Contract
Amount
$1,041,000.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
470
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />High Rock Road Waste and Recycling Center Improvements 33 10 00 - 6 <br />Orange County, North Carolina JULY 2021 <br />DAA PN: R00592-213N <br /> <br />2. Gasketed-Joint, PVC Water-Service Piping: According to AWWA M23. <br />3. Fire-Service-Main Piping: According to NFPA 24. <br />4. Apply full coat of asphalt or other acceptable corrosion-resistant material <br />to surfaces of installed ferrous anchorage devices. <br />3.6 VALVE INSTALLATION <br />A. AWWA Gate Valves: Comply with AWWA C600 and AWWA M44. Install each <br />underground valve with stem pointing up and with valve box. <br />B. UL/FM Gate Valves: Comply with NFPA 24. Install each underground valve <br />and valves in vaults with stem pointing up and with vertical cast-iron indicator <br />post. <br />C. Corporation Valves and Curb Valves: Install each underground curb valve with <br />head pointed up and with service box. <br />3.7 CONNECTIONS <br />A. Piping installation requirements are specified in other Division 2 Sections. <br />Drawings indicate general arrangement of piping and specialties. <br />3.8 FIELD QUALITY CONTROL <br />A. Piping Tests: Conduct piping tests before joints are covered and after thrust <br />blocks have hardened sufficiently. Fill pipeline 24 hours before testin g and <br />apply test pressure to stabilize system. Use only potable water. <br />B. Hydrostatic Tests: Test at not less than 1-1/2 times working pressure for 2 <br />hours. <br />1. Increase pressure in 50-psig (350-kPa) increments and inspect each joint <br />between increments. Hold at test pressure for 1 hour; decrease to 0 psig <br />(0 kPa). Slowly increase again to test pressure and hold for 1 or more <br />hours. Maximum allowable leakage is 2 quarts (1.89 L) per hour per 100 <br />joints. Remake leaking joints with new materials and repeat test until <br />leakage is within allowed limits. <br />C. Prepare reports of testing activities. <br />D. Contractor to arrange for all building inspector inspections. <br />DocuSign Envelope ID: BBF56E0A-3618-497E-AA70-92F097E8F598