Orange County NC Website
ASPHALT SHINGLESEXISTING CEMENTITIOUS WOODFIBER DECK, INSULATION,AND OSB COMPOSITE DECKNAILBASE, SECURE TO OSB PERSPECIFICATIONS. TRIM BACK INSULATION TOALLOW FOR PERIMETER BLOCKING.EXISTING EIFS OVERSHEATHINGEXISTING METAL STUDWALL WITH GYPSUMBOARD SHEATHINGON BOTH SIDESPRE-FINISHED METAL WALL PANELS WITHCONCEALED FASTENERS AND FLUSH JOINTS.SECURE TO HAT CHANNELS.SELF-ADHERED ICE AND WATER SHIELD, INSTALL ALONGPERIMETER EXTEND 30" ONTO ROOF AND TURN DOWN OVEREDGE. INSTALL SYNTHETIC UNDERLAYMENT OVER REST OFSURFACE, LAP OVER TOP EDGE OF ICE AND WATER SHIELDWOOD BLOCKING. SECURE TO EXISTING OSB ANDPERIMETER BLOCKING @ 12" O.C. TO PROPERLYPOSITION THE NAILBASE1" DEEP HAT CHANNELSSPACED @ 24" O.C.MAX. SECURE THROUGHEIFS AND SHEATHING INTOEACH METAL STUDCONTINUOUS CLEAT SECURED@ 12" O.C.CONTINUOUS CLEAT SECURED @ 12" O.C.EXISTING WOOD BLOCKING,PRE-FINISHED FASCIA EXTENSION,SECURED @ 12" O.C. BOTTOM TO MATCHEXISTING SOFFIT DEPTHPRE-FINISHED METAL DRIP EDGE,SECURED AT FLANGE WITH NAILS@ 3" O.C. STAGGEREDPRE-FINISHED J-TRIMSECURED TO ANGLE @ 12" O.C.COLD-FORMED ANGLE, SECURED TO WALL PANEL @ 12" O.C.PRE-FINISHED J-TRIM SECURED TOANGLE @ 12" O.C.PRE-FINISHED VENTED SOFFIT PANELS, SECURE TOJ-TRIM/ANGLEWOOD BLOCKING, SECURE TO ANGLES @12" O.C. STAGGERED.COLD-FORMED ANGLES, SECUREDTO PERIMETER DECK ANGLE @12" O.C; ADJUST TO MAINTAINSOFFIT AT ORIGINAL ELEVATION.(SOFFIT ELEVATION MAY BE RAISED IFEXISTING CONDITIONS WILL ALLOW)EXISTING CMU WALL1" DEEP HAT CHANNELSSPACED @ 24" O.C.MAX. SECURE THROUGH EIFSAND SHEATHINGINTO EACH METAL STUDWALL BASE TRIM AND CLOSURE,SECURED TO THE HAT CHANNELASPHALT SHINGLESEXISTING CEMENTITIOUS WOODFIBER DECK, INSULATION,AND OSB COMPOSITE DECKNAILBASE, SECURE TO OSB PER SPECIFICATIONS. FITINSULATION TIGHT TO WALLPRE-FINISHED METAL WALL PANELS WITHCONCEALED FASTENERS AND FLUSH JOINTS.SECURE TO HAT CHANNELS.WOOD BLOCKING SECURED THROUGHSHEATHING AT EACH METAL STUD TOPROVIDE NAILABLE SURFACE FORVENTED FLASHINGEXISTING METAL STUDWALL WITH GYPSUMBOARD SHEATHINGON BOTH SIDESEXISTING EIFS OVER SHEATHING. CUT AND REMOVE EIFSSYSTEM TO EXPOSE EXTERIOR SHEATHING BELOW ALLWINDOWS. AT OTHER LOCATIONS, REMOVE THE BOTTOM12" TO ALLOW FOR SHEATHING INSPECTION AND PROPERINSTALLATION OF THE NEW ROOF SYSTEM.1" DEEP HAT CHANNELS SPACED@ 24" O.C. MAX. SECURE THROUGHEIFS/INSULATION AND SHEATHING INTOEACH METAL STUDFOIL-FACED INSULATION INSTALLED TOREPLACE REMOVED EIFS DOWN TO THENEW NAILBASE INSULATION. SEAL ALLJOINTS WITH EIFS. TAPE ALL INSULATIONJOINTS AND OVER BLOCKINGSTRIP-IN TOP OF COUNTERFLASHINGWITH SELF-ADHERED FLASHINGWALL BASE TRIM AND CLOSURE,SECURED TO THE HAT CHANNELSELF-ADHERED ICE AND WATER SHIELD FOR 30" ALONGHIGH EAVE, WRAP EDGE OF PLYWOOD DECK BUT DO NOTBLOCK VENTING. OVERLAP OVER TOP OF SYNTHETICUNDERLAYMENT PRESENT OVER REST OFSURFACEEXPANDED METAL SUPPORT SCREEN SECUREDTO BRACKET AND WALLCONTINUOUS 20 GA. CLEATSET IN MASTIC AND SECURED THROUGHSHINGLES INTO THE DECK @ 6" O.C.PRE-FINISHED METAL FLASHING.SECURE WITH EXPOSED FASTENER WITHWASHER THROUGH COUNTERFLASHING INTOBLOCKING AND AT CLEATPRE-FINISHED COUNTERFLASHING,SECURED TO EACH STUD THROUGH THESHEATHING.PRE-FINISHED METAL FLASHING SECURED TOTHE EXISTING SILL FLASHING WITH POP RIVETSTHROUGH SEALANT AT 12" O.C.CONTINUOUS HAT CHANNEL SUPPORT SECUREDTHROUGH EIFS AND SHEATHING INTO EACHMETAL STUDPRE-FINISHED METAL WALL PANELS. FLUSH PROFILEWITH CONCEALED FASTENERS AND VERTICALORIENTATIONEXISTING WINDOWASSEMBLYEXISTING STUD WALLWITH SHEATHINGAND EIFSHAT CHANNELS @ 24" OC.,SECURED THROUGH EIFSAND SHEATHING INTO EACHMETAL STUDPRE-FINISHED WALL PANEL SECUREDTO HAT CHANNELPRE-FINISHED CORNER TRIMFASTEN TO HAT CHANNEL @ 12" OCAND RIVET TO WALL PANELEXISTING WINDOWASSEMBLYEXISTING STUD WALL WITHSHEATHING AND EIFSREPLACE SEALANTJOINTPRE-FINISHED CLOSURE TRIMFASTEN TO HAT CHANNEL @ 12" OCHAT CHANNEL @ 24" OC., SECUREDTHROUGH EIFS AND SHEATHING AT EACHMETAL STUDPRE-FINISHED WALL PANEL SECUREDTO HAT CHANNELPRE-FINISHED BASE TRIMFASTEN TO HAT CHANNEL @ 12" OCEXISTING WINDOWASSEMBLYREPLACE SEALANT JOINTAROUND PERIMETERPRE-FINISHED CLOSURE TRIMFASTEN TO HAT CHANNEL @ 12" OCASPHALT SHINGLESEXISTING CEMENTITIOUS WOODFIBER DECK, INSULATION,AND OSB COMPOSITE DECKNAILBASE, SECURE TO OSBPER SPECIFICATIONS. FITINSULATION TIGHT TO WALLEXISTING MASONRY WALLSELF-ADHERED ICE AND WATER SHIELD FOR 30" ALONGHIGH EAVE, FASTENED TO WALL AND UNDER EXISTINGFLASHING. OVERLAP OVER TOP OF SYNTHETICUNDERLAYMENT PRESENT OVER REST OF SURFACECONTINUOUS 20 GA. CLEATSET IN MASTIC AND SECURED THROUGHSHINGLES INTO THE DECK @ 6" O.C.PRE-FINISHED METAL FLASHING.SECURE WITH EXPOSED FASTENER WITHWASHER THROUGH COUNTERFLASHING INTO MASONRYEXISTING FLASHING TRIMMEDTO FORM RECEIVEREXISTING WINDOW - REMOVE ANDREPLACE PERIMETER JOINT SEALANT12-14 X 1-1/4 SD FASTENEREXISTING WINDOW SILL FLASHING(PROTECT FOR REUSE)REPLACE SEALANT JOINT (DO NOTBLOCK WEEPS IF PRESENT)1"3"REMOVE EIFS DIRECTLY BELOWWINDOW (12") TO INSPECT/REPAIRSHEATHING. INSTALL NEW FOILFACED INSULATION TO REPLACEREMOVED AREA AND SEAL JOINTSWITH EIFS.SILLHEADJAMBNOTE: SEE DETAIL 12/2.3 FOR WALL PANELDETAILS AT WINDOWSNo.REVISIONByDateDRAWN BY:ENGINEER:APPROVAL:DATE:PROJ.:SCALE:DWG. NO.2.3KEW/RTKEWAS SHOWNBID DOCUMENTS/PERMIT SETJ240008/09/2021CONSTRUCTION DETAILS <br />MOTOR POOL MAIN BUILDING ROOF REPLACEMENT <br />HILLSBOROUGH, NORTH CAROLINA <br />ORANGE COUNTY ASSET MANAGEMENT SERVICESRAKE WALL92.3SCALE: 3" = 1'-0"HEAD WALL TO WALL PANELS102.3SCALE: 3" = 1'-0"HEAD WALL TO MASONRY112.3SCALE: 3" = 1'-0"HEAD JAMB, JAMBS, AND SILL TO METAL PANEL122.3SCALE: 3" = 1'-0"DocuSign Envelope ID: 9514E4EC-C3C9-4752-8A7F-22E83B22BB8E