Orange County NC Website
PRE-FINISHED DOWNSPOUT. SIZE, GENERAL PROFILE TO MATCHEXISTING. CONNECT TO GUTTER WITH OUTLET. SECURE WITH PRE-FINISHED STRAPS AT SAME LOCATIONS AS EXISTING. IF STRAP SPACINGEXCEEDS 8', INSTALL ADDITIONAL STRAPS AT CONSISTENT SPACING.DOWNSPOUT TO DISCHARGE IN SAME MANNER AS EXISTING(I.E. ONTO ADJACENT ROOF, ONTO GROUND)PRE-FINISHED GUTTER. SIZE AND GENERAL PROFILETO MATCH EXISTING. BACK LEG TO EXTEND A MIN. OF 1"HIGHER THAN OUTER LIP. SECURE THROUGH BACK LEG TOANGLE SUPPORT AND WALL PANEL WITH SCREWS @ 6" O.C.EVERY THIRD FASTENER WILL SECURE A GUTTER SPACER/STRAP (18"O.C.). FRONT EDGE OF GUTTER MUST BE AMIN. 1" BELOW THE ROOF EDGE.1"STARTER SHINGLE INSTALLED ALONG EAVE PRIOR TOFIRST COURSE OF SHINGLES. SECURE PER THEMANUFACTURER INSTALLATION REQUIREMENTS.ASPHALT SHINGLESPRE-FINISHED METAL DRIP EDGE, SECURED ATFLANGE WITH NAILS @ 3" O.C. STAGGEREDSELF-ADHERED ICE AND WATER SHIELD, INSTALL SMALL PIECE ALONGEAVE BEFORE DRIP EDGE. INSTALL ICE AND WATER SHIELD ALONG BOTTOM30" OF EAVE, OVERLAP TOP EDGE OF DRIP EDGE. INSTALL SYNTHETICUNDERLAYMENT OVER REST OF SURFACE, LAP OVER TOP EDGE OFICE AND WATER SHIELDEAVE ANGLE SUPPORT, SECURED TO DECK @ 12" O.C.EXISTING JOIST EXTENSIONSEXISTING CMU WALLEXISTING STEEL ANGLE/STOPAND PERIMETER WOOD BLOCKINGWOOD BLOCKING. SECURE TO EXISTING OSB AND PERIMETERBLOCKING @ 12" O.C. TO PROPERLY POSITION THE NAILBASEMIN. 2" WIDE FLAT PLATE (OR ANGLE), CONTINUOUS, SECURED TOEACH HAT CHANNEL TO PROVIDE SECUREMENT POINT FOR WALLPANELS IF JOINTS DO NOT ALIGN WITH HAT CHANNELSPRE-FINISHED METAL WALL PANELS WITH CONCEALED FASTENERSAND FLUSH JOINTS1-1/2" DEEP HAT CHANNELS SPACED @ 12" O.C.MIN. 2" WIDE FLAT PLATE (OR ANGLE), CONTINUOUS, SECURED TO EACHHAT CHANNEL TO PROVIDE SECUREMENT POINT FOR WALL PANELS IFNOT ALIGNED WITH HAT CHANNELSPRE-FINISHED J-TRIMSECURED TO ANGLE @12" O.C.COLD-FORMED ANGLE,SECURED TO WALL@ 12" O.C. STAGGEREDREMOVE EXISTING COLD-FORMED FRAMING TOALLOW FOR INSTALLATIONOF NEW COMPONENTS.LOCATED NEW FRAMINGSO THAT SOFFIT WILL BELOCATED AT THE SAMEELEVATION UNLESSOTHERWISE APPROVEDBY THE DESIGNER.COLD-FORMED CHANNELOR ANGLE, AT EACH HATCHANNEL, SECURED TOANGLES WITH 2 FASTENERSPER CONNECTIONWALL BASE TRIM AND CLOSURE, SECURED TO THE HAT CHANNELPRE-FINISHED J-TRIM SECURED TO ANGLE @ 12" O.C.PRE-FINISHED VENTED SOFFIT PANELS, SECURE TO J-TRIM/ANGLEINSTALL GUTTER GUARDSUPPORTED BY SPACERS/STRAP AND FASTENED TOOUTER LIP (NOT SHOWN)ASPHALT SHINGLESPRE-FINISHED METAL DRIP EDGE, SECURED ATFLANGE WITH NAILS @ 3" O.C. STAGGEREDSELF-ADHERED ICE AND WATER SHIELD, INSTALL ALONGPERIMETER EXTEND 30" ONTO ROOF AND TURN DOWN OVEREDGE. INSTALL SYNTHETIC UNDERLAYMENT OVER REST OFSURFACE, LAP OVER TOP EDGE OF ICE AND WATER SHIELDWOOD BLOCKING. SECURE TO EXISTING OSB ANDPERIMETER BLOCKING @ 12" O.C. TO PROPERLYPOSITION THE NAILBASEEXISTING CEMENTITIOUS WOODFIBER DECK, INSULATION,AND OSB COMPOSITE DECKEXISTING CMU WALL1" DEEP HAT CHANNELS SPACED @ 24" O.C.MAX. SECURE THROUGH EIFS AND SHEATHINGINTO EACH METAL STUDWALL BASE TRIM AND CLOSURE,SECURED TO THE HAT CHANNELEXISTING EIFS OVERSHEATHINGEXISTING METAL STUDWALL WITH GYPSUMBOARD SHEATHINGON BOTH SIDESNAILBASE, SECURE THROUGHTO OSB PER SPECIFICATIONS.TRIM BACK INSULATION TO ALLOWFOR PERIMETER BLOCKING.CONTINUOUS CLEAT SECURED @ 12" O.C.CONTINUOUS CLEAT SECURED @ 12" O.C.WOOD BLOCKING, SECURE TO EXISTING BLOCKING@12" O.C. STAGGERED TO BRING BLOCKING FLUSHWITH THE NEW WALL PANELSEXISTING WOODBLOCKINGPRE-FINISHED METAL WALL PANELS WITHCONCEALED FASTENERS AND FLUSH JOINTS.SECURE TO HAT CHANNELS. EXTEND PASTBOTTOM OF EIFS AND COVER CMU. BOTTOMELEVATION TO MATCH SOFFIT AT EAVEPRE-FINISHED FASCIA EXTENSION, SECURED @12" O.C. OVERLAP WALL PANEL BY 1.5" MIN.ASPHALT SHINGLESPRE-FINISHED METAL DRIP EDGE,SECURED AT FLANGE WITH NAILS@ 3" O.C. STAGGEREDSELF-ADHERED ICE AND WATER SHIELD, INSTALL ALONGPERIMETER EXTEND 30" ONTO ROOF AND TURN DOWN OVER EDGETO COVER WOOD. INSTALL SYNTHETIC UNDERLAYMENT OVERREST OF SURFACE, LAP OVER TOP EDGE OF ICE AND WATERSHIELDWOOD BLOCKING. SECURE TO EXISTING OSBAND PERIMETER BLOCKING @ 12" O.C. TOPROPERLY POSITION THE NAILBASEEXISTING CEMENTITIOUS WOODFIBER DECK, INSULATION,AND OSB COMPOSITE DECKNAILBASE, SECURE TO OSBPER SPECIFICATIONS.TRIM BACK INSULATION TO ALLOWFOR PERIMETER BLOCKING.CONTINUOUS CLEAT SECURED@ 12" O.C.PRE-FINISHED FASCIA EXTENSION,SECURED @ 12" O.C. BOTTOMELEVATION TO REMAIN CONSISTENTWITH DETAIL AT WALL PANELSCONTINUOUS CLEAT SECURED@ 12" O.C.WOOD BLOCKING TO MATCHFASCIA AT WALL PANELS, SECURETO EXISTING BLOCKING @12"O.C. STAGGEREDEXISTING CMU WALLWOOD BLOCKING TO MATCH BOTTOMOF FASCIA, SECURED @ 12" O.C.PRE-FINISHED CLOSURE METALASPHALT SHINGLESEXISTING CEMENTITIOUS WOODFIBER DECK, INSULATION,AND OSB COMPOSITE DECKNAILBASE, SECURE TO OSBPER SPECIFICATIONS.TRIM BACK INSULATION TO ALLOWFOR PERIMETER BLOCKING.EXISTINGWOODBLOCKINGEXISTING EIFS OVERSHEATHINGEXISTING METAL STUDWALL WITH GYPSUMBOARD SHEATHINGON BOTH SIDESPRE-FINISHED METAL WALL PANELS WITHCONCEALED FASTENERS AND FLUSH JOINTS.SECURE TO HAT CHANNELS.SELF-ADHERED ICE AND WATER SHIELD, INSTALL ALONGPERIMETER EXTEND 30" ONTO ROOF AND TURN DOWN OVEREDGE. INSTALL SYNTHETIC UNDERLAYMENT OVER REST OFSURFACE, LAP OVER TOP EDGE OF ICE AND WATER SHIELDWOOD BLOCKING. SECURE TO EXISTING OSB ANDPERIMETER BLOCKING @ 12" O.C. TO PROPERLYPOSITION THE NAILBASE1" DEEP HAT CHANNELSSPACED @ 24" O.C.MAX. SECURE THROUGHEIFS AND SHEATHING INTOEACH METAL STUDCONTINUOUS CLEAT SECURED@ 12" O.C.CONTINUOUS CLEAT SECURED @ 12" O.C.EXISTING WOOD BLOCKING,PRE-FINISHED FASCIA EXTENSION,SECURED @ 12" O.C. BOTTOM TO MATCHEXISTING SOFFIT DEPTHPRE-FINISHED METAL DRIP EDGE,SECURED AT FLANGE WITH NAILS@ 3" O.C. STAGGEREDPRE-FINISHED J-TRIMSECURED TO ANGLE @ 12" O.C.COLD-FORMED ANGLE, SECURED TO WALL PANEL @ 12" O.C.PRE-FINISHED J-TRIM SECURED TOANGLE @ 12" O.C.PRE-FINISHED VENTED SOFFIT PANELS, SECURE TOJ-TRIM/ANGLEWOOD BLOCKING, SECURE TO ANGLES @12" O.C. STAGGERED.EAVE TRIM, SECURED @ 12" O.C. EXTEND TO MATCHBOTTOM OF FASCIA AT RAKECOLD-FORMED ANGLES, SECUREDTO PERIMETER DECK ANGLE @12" O.C; ADJUST TO MAINTAINSOFFIT AT ORIGINAL ELEVATION.(SOFFIT ELEVATION MAY BE RAISED IFEXISTING CONDITIONS WILL ALLOW)EXISTING CEMENTITIOUS WOODFIBER DECK, INSULATION,AND OSB COMPOSITE DECKNAILBASE, SECURE THROUGHTO OSB PER SPECIFICATIONS.TRIM BACK INSULATION TO ALLOWFOR PERIMETER BLOCKING.No.REVISIONByDateDRAWN BY:ENGINEER:APPROVAL:DATE:PROJ.:SCALE:DWG. NO.2.1KEW/RTKEWAS SHOWNCONSTRUCTION DETAILS <br />MOTOR POOL MAIN BUILDING ROOF REPLACEMENTJ240008/09/2021HILLSBOROUGH, NORTH CAROLINA <br />ORANGE COUNTY ASSET MANAGEMENT SERVICESBID DOCUMENTS/PERMIT SETRAKE EDGE WITH WALL PANELS22.1SCALE: 3" = 1'-0"RAKE EDGE32.1SCALE: 3" = 1'-0"EAVE WITH GUTTER AT CMU12.1SCALE: 3" = 1'-0"RAKE EDGE WITH SOFFIT42.1SCALE: 3" = 1'-0"DocuSign Envelope ID: 9514E4EC-C3C9-4752-8A7F-22E83B22BB8E