2021-586-E-AMS-Wayne Roofing & Sheet Metal Company-Motor Pool Facility Replace Existing Roof System
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-586-E-AMS-Wayne Roofing & Sheet Metal Company-Motor Pool Facility Replace Existing Roof System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2021 2:35:49 PM
Creation date
10/18/2021 2:33:45 PM
Metadata
Fields
Template:
Contract
Date
10/14/2021
Contract Starting Date
10/14/2021
Contract Ending Date
10/18/2021
Contract Document Type
Contract
Amount
$209,407.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />073113.1 – ASPHALT SHINGLED ROOF SYSTEM <br /> <br />Project Manual for Motor Pool Main Building Roof Replacement <br />Orange County, Hillsborough, NC <br />Prepared by Atlas Engineering, Inc., 551-A Pylon Drive – Raleigh, NC 27606 <br />August 2021 <br /> <br />SECTION 073113 <br /> <br />ASPHALT SHINGLED ROOF SYSTEM <br /> <br />PART 1 GENERAL <br /> <br />1.01 WORK INCLUDED <br /> <br />A. Inspect the composite roof deck, wood blocking, and other components to remain and repair or <br />replace damaged or deteriorated materials in accordance with this section and Section 061000 of <br />these specifications. <br /> <br />B. Base Bid: Install nailbase insulation mechanically fastened to the existing OSB. <br /> <br />C. Alternate Bid 01: Install vented nailbase insulation mechanically fastened to the existing OSB in <br />lieu of the standard nailbase. <br /> <br />D. Install one layer of self-adhered underlayment at the eaves, ridges, rakes, and high eave. Install <br />synthetic underlayment on remainder of roof. <br /> <br />E. Install new laminated, dimensional asphalt shingles in accordance with applicable sections of the <br />specifications. The new shingled roof system must meet the requirements for UL Class A fire <br />classifications and wind uplift resistance in accordance with these specifications, the North <br />Carolina State Building Code and ASCE-7, latest edition. <br /> <br />F. Install new sheetmetal flashings, trim, wall panels, and other associated transition flashings and <br />accessories in accordance with Section 076200. <br /> <br />G. Install other accessory items such as fasteners, sealants, tape sealants, mastics, and ridge vent <br />components, as necessary to provide a complete and watertight installation in accordance with the <br />specifications, design drawings, and the warranting manufacturer’s installation instructions. <br /> <br />1.02 QUALITY ASSURANCE <br /> <br />A. Contractor shall have a minimum of five years of experience in the installation of asphalt shingle <br />roof systems and accessories. Contractor must have the necessary certifications from the <br />approved shingle manufacturers to install and provide the specified warranty coverages. <br /> <br />B. Use adequate number of skilled workmen who are trained and experienced in the necessary crafts <br />and who are familiar with the specified requirements and the methods needed for performance of <br />the Work. <br /> <br />C. When specified in respective Specification Sections or required to obtain specified system <br />warranties, require manufacturer to provide qualified personnel to observe field conditions, <br />conditions of surfaces and installation, quality of workmanship, as applicable, and to make <br />appropriate recommendations. <br /> <br />DocuSign Envelope ID: 9514E4EC-C3C9-4752-8A7F-22E83B22BB8E