Browse
Search
2021-586-E-AMS-Wayne Roofing & Sheet Metal Company-Motor Pool Facility Replace Existing Roof System
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-586-E-AMS-Wayne Roofing & Sheet Metal Company-Motor Pool Facility Replace Existing Roof System
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2021 2:35:49 PM
Creation date
10/18/2021 2:33:45 PM
Metadata
Fields
Template:
Contract
Date
10/14/2021
Contract Starting Date
10/14/2021
Contract Ending Date
10/18/2021
Contract Document Type
Contract
Amount
$209,407.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />061000.4 – ROUGH CARPENTRY <br /> <br /> <br />Project Manual for Motor Pool Main Building Roof Replacement <br />Orange County, Hillsborough, NC <br />Prepared by Atlas Engineering, Inc., 551-A Pylon Drive – Raleigh, NC 27606 <br />August 2021 <br />roof deck to resist a minimum uplift force of 300 pounds per linear foot, but no more than 12" o.c. <br />apart unless a more stringent spacing is required to meet FM Loss Prevention Data Sheet 1-49. If <br />fastener pull-out values performed by the Contractor prior to start of work indicate that specified <br />fastening patterns will not meet this requirement, increase the number of fasteners as necessary to <br />meet requirement. <br /> <br />E. Fasteners shall be positioned 6" from each end and a maximum of 12″ on center and staggered 1/3 <br />the nailer width. Two fasteners shall be installed at ends of nailer lengths. Wood nailer pieces shall <br />be no less than 12″ in length and shall be secured with a minimum of two fasteners per piece. <br /> <br />F. All nailers shall finish flush with the insulation. <br /> <br />G. Install new wood materials true to line, level, plumb, and securely fastened to the approved substrate <br />with fastener type and fastening requirements as specified. <br /> <br />H. New wood nailers shall have a 1/4" gap between each length. <br /> <br />I. Where new or raised wood curbs are to be installed, corners shall be formed by lapping side <br />members alternately. <br /> <br />3.03 OSB REPLACEMENT <br /> <br />A. Remove damaged/deteriorated portion of OSB when it has delaminated from the insulation <br />beneath. <br /> <br />B. Cut new OSB to fit size of removed section. Allow for a minimum 1/8" gap between the boards <br />for movement. Joints of new OSB board should be installed with 1/8” gaps. <br /> <br />C. Secure the OSB to the cementitious wood fiber deck through the insulation with fasteners @ 12” <br />o.c. along the perimeters and no more than 24” o.c. in the field of the OSB board. <br /> <br />3.04 CEMENTITIOUS WOOD FIBER COMPOSITE DECK REPLACEMENT <br /> <br />A. At locations where the existing composite roof deck is damaged full depth or the cementitious <br />wood fiber portion of the deck is damaged, remove the damaged/deteriorated portion of the plank <br />deck down to the steel structure. Unless otherwise recommended by the manufacturer, the new <br />deck should extend over a minimum of three spans. <br /> <br />B. Install construction adhesive along the top of the joist and panel edges in accordance with the <br />manufacturer’s requirements/recommendations. <br /> <br />C. Install new composite deck into opening. <br /> <br />D. Secure deck to the steel joist in accordance with the manufacturer’s requirement. Minimum of 4 <br />screws per bearing. <br /> <br />END OF SECTION 061000 <br />DocuSign Envelope ID: 9514E4EC-C3C9-4752-8A7F-22E83B22BB8E
The URL can be used to link to this page
Your browser does not support the video tag.