Browse
Search
Agenda - 11-24-2003-c1a
OrangeCountyNC
>
Board of County Commissioners
>
BOCC Agendas
>
2000's
>
2003
>
Agenda - 11-24-2003
>
Agenda - 11-24-2003-c1a
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2013 3:57:17 PM
Creation date
8/29/2008 10:36:02 AM
Metadata
Fields
Template:
BOCC
Date
11/24/2003
Document Type
Agenda
Agenda Item
c1a
Document Relationships
Minutes - 20031124
(Linked To)
Path:
\Board of County Commissioners\Minutes - Approved\2000's\2003
ORD-2003-142 PD-1-03 State Employees Credit Union Addition Special use permit
(Linked From)
Path:
\Board of County Commissioners\Ordinances\Ordinance 2000-2009\2003
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
018 <br />Town <br />of <br />11111S <br />im vs <br />Mr.. Elmar D. Kapfer, PE. <br />TITAN ATLANTIC GROUP <br />5240 Green's Dairy Road <br />Dear Mr, K,apfer: <br />��IV <br />October 27, 2003 <br />Re: State Employees' Credit Union <br />Drive -Up Facility and Expansion/Renovation <br />2313 Old NC 86 <br />Water & Sewer Review <br />APPROVED AS NOTED <br />I have reviewed the water and sewer utilities plans for the State Employees' Credit Union Drive - <br />Up Facility and Expansion/Renovation dated August 7, 2003, and they are hereby Approved as <br />Noted. The following comments must be addressed prior to construction (all comments are in <br />reference to Sheet LA -.3): <br />1 Backilow Prevention: A DCVA backflow preventer must be installed immediately <br />following the water meter, above - ground with an insulated box cover,. Annual testing will <br />be required of the customer, with testing data submitted to the Town. <br />2., Sanitary Sewer Profile: The length and percent grade of each section of gravity sewer <br />must be shown on the sanitary sewer profile. <br />3 Sewer Bore & Jack/Encasement Pipe: The encasement pipe must be a minimum of 12" <br />to provide adequate clearance for the 8" DI sewer pipe joints, Also, DIP is noted for the <br />encasement pipe, however, steel encasement pipe is acceptable <br />4. Water & Sewer Connection Fees: An invoice is attached, which details the fees <br />required for connection to the Town water and sewer system.. The Water Capital <br />Facilities Fee is not assessed since the existing water service will be utilized <br />Further instructions on the Town requirements during and after construction can be found in the <br />"Checklist for Approval and Acceptance of Utilities Projects", which is available from my office <br />and on the Town website (www ci hillsborough nc.us). The permit application to NCDWQ for <br />the sewer extension should be prepared for signature by the Town Manager, Eric 7, Peterson. <br />The Hillsborough Utility Inspector (Russell Lloyd, 919 -201 -1432) should be notified prior to <br />construction, and prior to any testing of the water and sewer facilities to be installed. As always, <br />you may notify my office if you are unable to reach the inspector. <br />101 East Orange Street • P.O. Box 429 • Hillsborough, North Carolina 27278 <br />o <br />Q/a.7 ?9.. 797n. P-- 010 ann.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.