Orange County NC Website
8/28/2020 Print : Quotebuilder : ServiceTrade <br />https://app.servicetrade.com/quotebuilder/print/id/1252752 1/4 <br />Description of Work <br />Allison, <br />The link below will take you to the proposal for the deficiencies found during the annual fire sprinkler inspection. <br />If you would like us to schedule this work, please click the green "APPROVE" button on the top right corner. <br />If you have any questions, please feel free to call me. <br />Theresa <br />All work listed on the proposal must be accepted and scheduled for the same date to maintain the proposal pricing. <br />The owner/owner's representative shall place alarm systems on test and restore upon completion of work. <br />EXCLUSIONS: <br />Any Additional Work NOT Specifically Listed in the proposal <br />No Draining of Low Point Drains Other Than At The Time of The Service <br />Over Time And/or After-Hours Costs Weekends And/or Holidays <br />Lift rental to perform the NFPA-25 code required internal pipe investigation and/or service work <br />Sprinkler Service & Inspection Deficiencies <br />FESS Fire Protection appreciates the opportunity to provide you with the following proposal to correct your fire sprinkler system deficiencies. All services will be <br />completed by qualified personnel in accordance with NFPA 25. This proposal includes all materials, labor, and permits for the work listed. Additional work will be <br />quoted separately upon request. <br />All services are performed during normal work hours Monday through Friday 7:00 am to 5:00 pm (excluding holidays), unless otherwise agreed upon in advance. <br />Services to be completed <br />[Sprinkler] Location - Building <br />NFPA-25 CODE REQUIRED 5-YEAR INTERNAL WET PIPE & ALARM VALVE OBSTRUCTION INVESTIGATION IS DUE: (5) <br />NFPA-25 CODE REQUIRED 5-YEAR INTERNAL DRY PIPE & DRY VALVE OBSTRUCTION INVESTIGATION IS DUE: (1) <br />5-year internal inspection due on (5) Wet Systems, and (1) Dry system <br />[Sprinkler] Location - Building <br />REPLACE NFPA-25 CODE REQUIRED 300PSI GAUGES OUT OF CALIBRATION: (6) <br />(6) Gauges are out of date. 2010 gauges <br />[Sprinkler] Dry Sprinkler - RISER ROOM - UNDER STAIRCASE - DRY SYSTEM <br />NFPA-25 CODE REQUIRED (2) HOUR 3-YEAR AIR LEAK TEST IS DUE: (1) <br />3-year air leak test is due on (1) Dry System <br />[Stand Pipe] Location - Building <br />NFPA-25 CODE REQUIRED 5-YEAR STANDPIPE FLOW TEST IS DUE: (2) <br />Due for 5-year flow testing on (2) Standpipes <br />From FESS Fire Protection <br />131 International Drive <br />Morrisville NC 27560 <br />(919)663-0400 <br />www.fessfire.com <br />Quote No.1252752 <br />Type Inspection Repair <br />Prepared By Theresa Bailey <br />Created On 07/06/2020 <br />Valid Until 09/30/2020 <br />Quote For Asset Management Services <br />Orange County (Billing) <br />Orange County - Whitted Human <br />Services Center Complex <br />300 West Tryon Street <br />Hillsborough NC 27278 <br />(919) 245-2625 <br />DocuSign Envelope ID: F3A3E126-E516-42D3-A7D4-020878A9D80B