Orange County NC Website
A COMBINATION STARTER SHALL BE USED IN LIEU OF A SEPARATE <br />SIZES TO HVAC AND PLUMBING EQUIPMENT <br />SEE PANELBOARD SCHEDULES FOR WIRE AND BREAKER <br />BRANCH CIRCUIT AND CONDUIT IN ELECTRICAL WORK. <br />TO STARTER OR DISCONNECT <br />WIRING IS CONNECTED DIRECTLY <br />EQUIPMENT (NOT NECESSARY IF <br />ELECTRICAL PLANS FOR SOME <br />JUNCTION BOX MAY BE SHOWN ON <br />WIRING IN ELECTRICAL WORK <br />DISCONNECT SWITCH AND STARTER, WHERE AVAILABLE. <br />CONTRACTOR OR OTHER TRADES <br />TO BE MADE BY THE HVAC OR PLUMBING <br />FINAL CONNECTIONS INSIDE EQUIPMENT <br />* <br />FOR LOCATION OF ALL EQUIPMENT <br />PLUMBING, AND ARCHITECTURAL PLANS <br />OR WORK OF OTHER TRADES. SEE HVAC, <br />EQUIPMENT IN HVAC OR PLUMBING WORK <br />ELECTRICAL CONTRACTOR. CONTROL <br />LINE AND LOAD CONNECTIONS BY THE <br />INSTALLED BY THE ELECTRICAL CONT. <br />FURNISHED BY HVAC OR PLUMBING <br />OTHER TRADES AND INSTALLED BY THE <br />HVAC OR PLUMBING CONTRACTOR, OR <br />DISCONNECT SWITCH FURNISHED BY <br />EXTERNALLY OR INTERNALLY MOUNTED <br />CONNECTIONS BY OTHERS <br />CONTRACTOR OR OTHER TRADES, <br />EXTERNALLY MOUNTED STARTER <br />* <br />CONNECTIONS BY OTHERS. <br />ELECTRICAL CONTRACTOR. CONTROL SWITCH) <br />PANELBOARD <br />J <br />WIRING IN ELECTRICAL WORK <br />JUNCTION BOX <br />ATTACHED <br />TO STRUCTURE <br />BRANCH CIRCUIT <br />CONDUIT (1/2" EMT) <br />FOR EACH FIXTURE, PROVIDE TWO STEEL <br />WIRE SUPPORTS TO STRUCTURE, ONE <br />WIRE <br />AT EACH CORNER OF THE FIXTURE, THEN <br />SCREW FIXTURE TO THE MAIN RUNNERS <br />OF <br />THE LAY-IN CEILING TRACK, AT THE FOUR <br />CORNERS, WITH SHEET METAL SCREWS. <br />FOR FIRE-RATED CEILING, FIXTURE SHALL <br />BE SUPPORTED BY TWO WIRES TO THE <br />BUILDING STRUCTURE. ONE WIRE SHALL <br />BE USED TO SUPPORT THE FIXTURE AT <br />EACH END. <br />1. <br />2. <br />6 FEET LENGTH OF FLEXIBLE <br />CONDUIT <br />TO ALLOW FOR RELOCATION. <br />INCLUDE <br />GROUND WIRE. ALL CONDUCTORS # <br />12 <br />AWG COPPER, MAXIMUM OF THREE(3) <br />FLEXIBLE RUNS PER JUNCTION BOX. <br />LAY-IN TYPE <br />TROFFER <br />GRID TYPE <br />INVERTED <br />"T" CEILINGACOUSTICAL PANEL <br />WORKING CLEARANCE FOR ELECTRICAL EQUIPMENT <br /> N.E.C ARTICLE 110-26 <br />DEDICATED SPACE FOR ELECTRICAL EQUIPMENT <br /> N.E.C ARTICLE 110-26(F)(1) <br />PANEL <br />PANELOK <br />OK <br />SUSPENDE <br />D <br />CEILING <br />STRUCTURAL <br />CEILING <br />FIXTURE <br />SIDE VIEW FRONT VIEW <br />SECTION <br />110-26 <br />WORKING <br />SPACE <br />SECTION <br />110-26 <br />WORKING <br />SPACE <br />PANEL <br />PANELDEDICATED <br />ELECTRICAL <br />SPACE <br />OK <br />OK <br />SUSPENDED <br />CEILING <br />STRUCTURA <br />L <br />CEILING <br />FIXTURE <br />SIDE VIEW FRONT VIEW6' OR LESS6 1/2' MIN6 1/2' MIN30" MIN 30" MIN <br />T 919 781 8582 <br />F 919 781 3979 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />DRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEIDThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETPDC #20033 <br />C:\Users\chris.pdc\Documents\20033_OCC Europa_MEP_Central_Model_chrishoo.rvt5/28/2020 3:43:42 PME4-01 <br />ELECTRICAL <br />DETAILS <br />2020045 21 MAY 2020CONSTRUCTION DOCUMENTSWCM <br />TDAORANGE COUNTY, NCDSS SKILLS DEVELOPMENT CENTER100 Europa Dr Ste 190, Chapel Hill, NC 27517NOT TO SCALE <br />TYPICAL EQUIPMENT CONNECTIONS1 <br />NOT TO SCALE <br />LAY-IN FIXTURE MOUNTING2 <br />NOT TO SCALE <br />ELECTRICAL EQUIPMENT CLEARANCE3 <br />05/28/2020 <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE