Browse
Search
2020-598-E AMS-Muter Construction Europa upfit SDC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-598-E AMS-Muter Construction Europa upfit SDC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2021 1:20:38 PM
Creation date
8/30/2021 1:11:58 PM
Metadata
Fields
Template:
BOCC
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
475
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br />VERIFY OPERATION WITH LOCAL AHJ PRIOR TO PROGRAMMING.SHUTDOWN ALL AIR HANDLING UNITSSYSTEM INPUTS <br />1 <br />2 <br />3 <br />4 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />16 <br />17 <br />18 <br />19 <br />20 <br />21 <br />22 <br />23 <br />24 <br />25 <br />15 <br />26 <br />27 <br />5 <br />NOTIFICATION APPLIANCE SHORT CIRCUIT <br />GROUND FAULT <br />OPEN CIRCUIT <br />NAC PANELS LOW BATTERY <br />FIRE ALARM SYSTEM LOW BATTERY <br />FIRE ALARM SYSTEM AC POWER FAILURE <br />FLOW SWITCH AT SPRINKLER RISER <br />TAMPER SWITCHES AT SPRINKLER RISERS <br />TAMPER SWITCH @ PIV & BACKFLOW <br />AHU OVERRIDE SWITCH <br />SMOKE DETECTORS IN ELEVATOR SHAFT AND MACHINE ROOM <br />SMOKE DETECTOR 1ST, 2ND, 3RD, 4TH FLOOR ELEVATOR LOBBIES <br />SMOKE DETECTOR GROUND FLOOR ELEVATOR LOBBY <br />HEAT DETECTORS 2ND FLOOR <br />HEAT DETECTORS GROUND FLOOR <br />SMOKE DETECTORS 2ND FLOOR <br />SMOKE DETECTORS GROUND FLOOR <br />MANUAL PULL STATIONS 1ST FLOOR DISPLAY CHANGE OF STATUS AT FACPRECALL ELEVATORS TO ALTERNATE RECALL FLOORRECALL ELEVATORS TO PRIMARY RECALL FLOORTRANSMIT TROUBLE SIGNAL TO SUPERVISING STATIONTRANSMIT FIRE ALARM SIGNAL TO SUPERVISING STATIONACTUATE ALL EVACUATION SIGNALSACTUATE AUDIBLE COMMON TROUBLE SIGNALACTUATE COMMON TROUBLE SIGNAL INDICATORACTUATE AUDIBLE SUPERVISORY SIGNALACTUATE SUPERVISORY SIGNAL INDICATORACTUATE AUDIBLE ALARM SIGNALACTUATE GENERAL ALARM SPEAKERS/STROBESQPOMLKJIHGFEDCBA <br />MANUAL PULL STATIONS GROUND FLOOR <br />27 <br />26 <br />25 <br />24 <br />23 <br />22 <br />21 <br />20 <br />19 <br />18 <br />17 <br />16 <br />15 <br />14 <br />13 <br />12 <br />11 <br />9 <br />8 <br />7 <br />6 <br />5 <br />4 <br />3 <br />2 <br />1 <br />MANUAL PULL STATIONS 2ND FLOOR <br />DUCT DETECTORS PENTHOUSE PLATFORMS <br />28 <br />28 <br />29 <br />29 <br />30 <br />30 <br />31 <br />32 <br />31 <br />32 TRANSMIT SUPERVISORY SIGNAL TO SUPERVISING STATIONRUNLOCK ACCESS CONTROLLED EGRESS DOORSSACTIVATE ELEVATOR FIREMAN'S HATSHUNT TRIP POWER TO ELEVATOR910 <br />HEAT DETECTORS IN ELEVATOR SHAFT AND MACHINE ROOM <br />33 <br />T U V WRELEASE MAGNETICALLY HELD DOOR OPENSCLOSE FIRE/SMOKE DAMPERSX <br />TEMPERATURE SENSOR AT BACKFLOW <br />A. <br />MANUAL PULL STATIONS 3RD FLOOR <br />MANUAL PULL STATIONS 4TH FLOOR <br />SMOKE DETECTORS 1ST FLOOR <br />SMOKE DETECTORS 3RD FLOOR <br />SMOKE DETECTORS 4TH FLOOR <br />HEAT DETECTORS 1ST FLOOR <br />HEAT DETECTORS 3RD FLOOR <br />HEAT DETECTORS 4TH FLOOR <br />EXISTING <br />EDWARDS EST-2 <br />ADDRESSABLE <br />FIRE <br />ALARM <br />PANEL <br />TP <br />FS <br />TP <br />TS <br />TP <br />S S S <br />FFF <br />H H H <br />SSS <br />R <br />FIRE ALARM SIGNAL LINE CIRCUITS SHALL BE WIRED CLASS "A" AND NOTIFICATION <br />CIRCUITS SHALL BE WIRED CLASS "B" WITH THE END OF LINE RESISTOR CLEARLY <br />AND PERMANENTLY MARKED ON THE LAST DEVICE. <br />INDICATOR <br />ALARM <br />REMOTE <br />TYPICAL FOR ALL AIR <br />HANDLING UNITS. <br />120VAC (PROVIDE <br />BREAKER LOCK ON <br />BREAKER THAT <br />SERVES <br />PANEL) <br />TAMPER SWITCHES AT <br />SPRINKLER RISER <br />TAMPER SWITCHES <br />AT FIRE LINE BACKFLOW <br />PREVENTER <br />(1) TEMPERATURE <br />SENSOR AT FIRE LINE <br />BACKFLOW PREVENTER <br />(1) TAMPER SWITCH AT <br />POST INDICATING VALVE <br />(PIV)(EXTERIOR) <br />FLOW SWITCHES AT <br />SPRINKLER RISER <br />SHUTDOWN <br />AHU <br />AHU# <br />GENERAL FIRE ALARM RISER NOTES: <br />A.NEW FIRE ALARM SYSTEM COMPONENTS SHALL BE COMPATIBLE WITH EXISTING <br />EDWARDS EST-2 FACP. PROVIDE ALL PARTS AND PIECES REQUIRED FOR <br />INTERCONNECTION AND ALARM, TROUBLE AND SUPERVISORY SIGNALS. <br />B.SEE PLANS FOR LOCATIONS AND QUANTITIES OF ALL DEVICES. <br />C.ALL WIRING SHALL BE IN MINIMUM 3/4" CONDUIT. <br />D.BATTERY CALCULATIONS ARE REQUIRED WITH ALL SUBMITTALS. <br />E.TEST RESULTS ARE REQUIRED FOR ALL DEVICES. <br />F.PROVIDE SHUT-DOWN DEVICES FOR AIR HANDLERS SUPPLY FANS OF ALL <br />MECHANICAL EQUIPMENT. <br />G.VERIFY ROOM NUMBERS WITH ARCHITECT PRIOR TO PROGRAMMING SYSTEM. <br />H.ALL NAC PANELS SHALL HAVE A SMOKE DETECTOR MOUNTED <br />WITHIN 15'-0" OF PANEL. <br />I.A SMOKE DETECTOR SHALL BE MOUNTED WITHIN 15'-0" OF FACP AND REMOTE <br />ANNUNCIATOR. <br />J.IF ANY ARCHITECTURAL CHANGES ARE MADE THAT SHALL AFFECT ANY DEVICE <br />PLACEMENT, THIS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO <br />INSTALLATION. <br />K.THE MANUFACTURER'S AUTHORIZED REPRESENTATIVE SHALL BE NICET LEVEL 3 <br />CERTIFIED AND HAVE AT LEAST 2 YEARS OF EXPERIENCE INSTALLING FIRE ALARM <br />SYSTEMS. <br />L. <br />M.THE SHOP DRAWINGS SUBMITTALS FOR DEVICE LOCATIONS SHALL BE SUBMITTED TO <br />ENGINEER AND LOCAL (AHJ) FIRE MARSHALL PRIOR TO ANY INSTALLATION/ROUGH-IN <br />FOR FIRE ALARM DEVICES. <br />N.WIRING DIAGRAMS. LOCATION DRAWINGS, DEVICE CUT SHEETS AND VOLTAGE DROP <br />CALCULATIONS ARE REQUIRED WITH ALL SUBMITTALS. <br />O.THE FIRE ALARM SYSTEM PROVIDER SHALL PROVIDE ALL DOCUMENTATION AS <br />SPECIFIED IN THE INTERNATIONAL FIRE CODE SECTION 907 REQUIREMENTS AS PART <br />OF <br />HIS SHOP DRAWING SUBMITTALS. <br />THIS INCLUDES: <br />1.LOCATION DRAWINGS OF ALARM INITIATING AND NOTIFICATION DEVICES. <br />2.WIRING DIAGRAMS WITH CONDUCTOR TYPE AND SIZES. <br />3.LOCATIONS OF ALARM CONTROL AND TROUBLE SIGNALING EQUIPMENT. <br />4.POWER CONNECTION DETAILS AND WIRING SCHEMATICS. <br />5.BATTERY CALCULATIONS. <br />6.VOLTAGE DROP CALCULATIONS. <br />SD <br />SD <br />D <br />SDSDSD <br />HD <br />TVSS <br />ANNUNCIATOR IN RACPENTRY VESTIBULE <br />SLC LOOP <br />NAC <br />RELAY (PROVIDE (1) <br />AHU SHUTDOWN <br />PER MOTOR CONTROLLER) <br />HH H <br />7.MANUFACTURER'S MODEL NUMBERS, LISTING INFORMATION FOR EQUIPMENT, <br />DEVICES AND MATERIALS. <br />8.THE INTERFACE OF FIRE SAFETY CONTROL FUNCTIONS. <br />P.REFER TO DIVISION 28 SPECIFICATIONS. <br />Q.FIRE ALARM SIGNAL LINE CIRCUITS SHALL BE WIRED CLASS "A" AND NOTIFICATION <br />CIRCUITS SHALL BE WIRED CLASS "B" WITH THE END OF LINE RESISTOR CLEARLY AND <br />PERMANENTLY MARKED ON THE LAST DEVICE. <br />R.ALL FIRE ALARM SYSTEM WORK SHALL BE APPROVED BY THE LOCAL FIRE <br />MARSHAL PRIOR TO COMMENCING ANY FIRE ALARM WORK. <br />S.ALL RACPs SHALL BE SEMI RECESSED WITH INTEGRAL PUSH TO TALK MICROPHONES <br />T.FIRE ALARM SYSTEM SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA <br />72, 2013. <br />U.COORDINATE WITH THE FIRE PROTECTION CONTRACTOR FOR VOLTAGE, RELAY, ETC. <br />FOR CONNECTIONS OF SPRINKLER BELL. ALL WIRING, CONDUIT, RELAY, AND <br />INTERCONNECTIONS SHALL BE BY THE ELECTRICAL & FIRE ALARM CONTRACTORS. <br />V.ALL 120VAC POWER FOR CABINET SHALL BE PROVIDED FROM THE NEAREST <br />120V PANEL. BREAKER HASPS SHALL BE PROVIDED ON BREAKER SERVING <br />CABINET. <br />W.ELECTRICAL CONTRACTOR SHALL COORDINATE CLOSELY WITH FIRE ALARM <br />SUB-CONTRACTOR FOR ALL 120V AC POWER REQUIRED FOR THIS SYSTEM. IF ANY <br />ADDITIONAL CIRCUITS ARE REQUIRED THAT ARE NOT IDENTIFIED ON PLANS THE <br />ELECTRICAL CONTRACTOR SHALL PROVIDE THAT CIRCUIT FROM THE NEAREST 120V <br />PANEL, AS-BUILTS SHALL BE UPDATED TO REFLECT THE INSTALLED CONDITION. THIS <br />SHALL BE DONE AT NO ADDITIONAL COST TO THE PROJECT. <br />CEILING AUDIO/VISUAL DEVICES (TYP.) <br />CEILING VISUAL DEVICES (TYP.) <br />WALL MOUNTED VISUAL DEVICES (TYP.) <br />WALL <br />MOUNTED <br />AUDIO/VISUAL <br />DEVICES (TYP.) <br />ELEVATOR <br />RECALL <br />FUNCTIONS <br />THE PROJECT MANAGER SHALL BE NICET LEVEL 4 CERTIFIED AND HAVE AT LEAST 5 <br />YEARS OF EXPERIENCE INSTALLING FIRE ALARM SYSTEMS. <br />AND ZONE SELECTION SWITCHES. <br />X.UPDATE EXISTING ZONE MAPS UPON COMPLETION OF THE PROJECT. <br />NAC PANELS <br />NAC PANELS <br />SSS <br />Y.PROVIDE NOTIFICATION APPLIANCE CABINET (NAC) AS NEEDED TO SUPPORT <br />ADDITIONAL NOTIFICATION DEVICES.RISER LEGEND <br />EXISTING <br />NEW <br />FIRE ALARM DEVICE MOUNTING <br />COORDINATE WITH LOCAL AHJ <br />PRIOR TO ROUGH-IN <br />SPEAKER/STROBE <br />NFPA 72 AND ADA DEVICE <br />INSTALLATION REQUIREMENTS <br />3'-0" MINIMUM <br />ANNUNCIATOR <br />MANUAL PULL STATION <br />5'-0" MAXIMUM <br />0'-4" MINIMUM <br />SMOKE/ HEAT <br />MOUNT ON A <br />BOX <br />APPROVED <br />DETECTOR <br />96" MAXIMUM <br />TOP OF DEVICE <br />80" MINIMUM <br />BOTTOM OF DEVICE <br />5'-6" <br />FLOOR <br />FINISHED <br />CONTROL <br />PANEL <br />SPEAKER/ STROBE <br />AIR SUPPLY DIFFUSER OR <br />RETURN AIR OPENING <br />GRAPHIC <br />CONDUIT <br />& VISUAL DEVICES <br />MOUNT AUDIBLE <br />0'-4" MINIMUM, <br />SMOKE/ HEAT <br />DETECTOR <br />WALL SPEAKER <br />BOXES. <br />ON APPROVED <br />3'-8" <br />(3'-6" MINIMUM, <br />4'-0" MAXIMUM) <br />HINGED SIDE <br />1'-0" MAXIMUMSTROBE <br />T 919 781 8582 <br />F 919 781 3979 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />DRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEIDThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETPDC #20033 <br />C:\Users\chris.pdc\Documents\20033_OCC Europa_MEP_Central_Model_chrishoo.rvt5/28/2020 3:43:42 PME3-02 <br />FIRE ALARM <br />RISER/MATRIX <br />2020045 21 MAY 2020CONSTRUCTION DOCUMENTSWCM <br />TDAORANGE COUNTY, NCDSS SKILLS DEVELOPMENT CENTER100 Europa Dr Ste 190, Chapel Hill, NC 27517NOT TO SCALE <br />FIRE ALARM MATRIX2 <br />NOT TO SCALE <br />FIRE ALARM NETWORK RISER11 <br />NOT TO SCALE <br />F/A DEVICE MOUNTING3 <br />05/28/2020 <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE