SYMBOL LEGEND <br />J <br />SEE FIXTURE SCHEDULEBATTERY POWERED EMERGENCY FIXTURE - WALL MOUNTED <br />QUADRUPLEX GROUNDING TYPE RECEPTACLES IN A DOUBLE GANG BOX. <br />MOUNT AT 16" AFF TO BOTTOM OF OUTLET UNLESS OTHERWISE NOTED. <br />DESCRIPTION REMARKS <br />LUMINAIRE - LETTER DESIGNATES TYPE <br />LIGHT FIXTURE - LETTER DESIGNATES TYPE <br />EXIT LIGHT - ARROW INDICATES DIRECTION & SHADING INDICATES <br />ILLUMINATED FACE(S). <br />DUPLEX GROUNDING TYPE RECEPTACLE - AT 16" ABOVE FINISHED FLOOR <br />TO BOTTOM OF OUTLET, UNLESS OTHERWISE NOTED <br />WIRING AND CONDUIT INSTALLED CONCEALED IN WALL SPACE OR <br />ABOVE FINISHED CEILING <br />SEE FIXTURE SCHEDULE <br />SEE FIXTURE SCHEDULE <br />SEE FIXTURE SCHEDULE <br />HUBBELL 5362-X WITH 97101 <br />COVER <br />HOME RUN CIRCUIT TO PANELBOARD <br />JUNCTION BOX WITH REMOVABLE COVER - SIZE PER NATIONAL <br />ELECTRICAL CODE <br />HUBBELL 5362-X WITH 97101 <br />COVER <br />CONDUIT SLEEVES - SIZE AND QUANTITY AS SHOWN ON PLANS <br />SYMBOL <br />DUAL TECHNOLOGY WALL SWITCH SENSOR - COVERAGE: MAJOR MOTION <br />35'x30', MINOR MOTION 20'x15'. TIME DELAYS OF NO LESS THAN 15 <br />MINUTES. MOUNT AT +48" TO TOP OF OUTLET BOX. INSTALL AS PER <br />MANUFACTURER'S INSTRUCTIONS. <br />CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR WITH <br />ISOLATED RELAY AND WIDE ANGLE LENS. TIME DELAYS OF NO LESS THAN <br />15 MINUTES. INSTALL AS PER MANUFACTURER'S INSTRUCTIONS. <br />OR <br />WATTSTOPPER DSW-301 <br />OR APPROVED EQUAL BY <br />P&S OR LEVITON. <br />UNSWITCHED WIRING AND CONDUIT LEG ON LIGHTING PLANS. UNDER <br />FLOOR WIRING AND CONDUIT ON POWER PLANS. UNDER GROUND <br />WIRING AND CONDUIT ON SITE PLANS. <br />OS <br />3 <br />4 <br />3-WAY SWITCH - INSTALL AT 48" ABOVE FINISHED FLOOR TO TOP OF <br />OUTLET. SWITCH COLOR SELECTED BY ARCHITECT. <br />4-WAY SWITCH - INSTALL AT 48" ABOVE FINISHED FLOOR TO TOP OF <br />OUTLET SWITCH COLOR SELECTED BY ARCHITECT. <br />SINGLE POLE TOGGLE SWITCH - 48" ABOVE FINISHED FLOOR TO TOP OF <br />OUTLET, UNLESS OTHERWISE NOTED. <br />WATTSTOPPER DT300 OR <br />APPROVED EQUAL. BY P&S <br />OR LEVITON. <br />120/208 VOLT PANELBOARD WITH NEUTRAL AND GROUND BUS <br />ACCESSORIES. <br />277/480 VOLT PANELBOARD WITH NEUTRAL, AND GROUND BUS <br />ACCESSORIES. <br />TX DRY TYPE STEP DOWN TRANSFORMER 480-120/208 3 PHASE. <br />DISCONNECT SWITCH, HEAVY DUTY <br />S <br />SD <br />S <br />H <br />H WALL MOUNTED FIRE ALARM COMBINATION HORN/STROBE - #CD <br />INDICATES CANDELA RATING OF STROBE <br />CEILING MOUNTED FIRE ALARM STROBE ONLY - #CD INDICATES CANDELA <br />RATING OF STROBE <br />CEILING MOUNTED FIRE ALARM COMBINATION HORN/STROBE - - #CD <br />INDICATES CANDELA RATING OF STROBE <br />WALL MOUNTED FIRE ALARM STROBE ONLY - #CD INDICATES CANDELA <br />RATING OF STROBE <br />CEILING MOUNTED FIRE ALARM SMOKE DETECTOR <br />#CD <br />#CD <br />#CD <br />#CD <br />SEE SPECIFICATION <br />SEE SPECIFICATION <br />SEE SPECIFICATION <br />SEE SPECIFICATION <br />SEE SPECIFICATION <br />OS <br />CONNECTRAC 3.7 IN-CARPET POWER/TELECOM UNIT <br />CONNECTRAC 3.7 IN-CARPET WIREWAY WITH POWER AND TELECOM <br />WIRING AS REQUIRED. <br />400 WATT MINI INVERTER SERIES LIGHTING INVERTER. SECURE ABOVE <br />CEILING. PROVIDE SUPPORTS AS REQUIRED FOR UNIT. <br />EMERGI-LITE #EMIU-277-AD <br />OR EQUAL <br />LC#ELECTRICALLY HELD LIGHTING CONTACTOR. # INDICATES CONTACTOR <br />NUMBER. PROVIDE NUMBER OF POLES AS REQUIRED. <br />SQUARE-D, GE, EATON <br />OR SIEMENS <br />ABBREVIATIONS <br />ABBREV. <br />A <br />AC <br />A/C <br />ADA <br />AFF <br />AFG <br />AIC <br />AL <br />ANSI <br />ATSC <br />ATS <br />A/V <br />AWG <br />BAS <br />BFC <br />C <br />CB <br />CCTV <br />CKT <br />CT <br />CU <br />D <br />DDC <br />DB <br />DC <br />DL <br />DISC <br />E <br />ECB <br />EWC <br />EX <br />FUT <br />FA <br />FACP <br />FATC <br />FDR <br />GAA <br />GAP <br />GEN <br />GEC <br />GFI <br />GFCI <br />GFEP <br />GFP <br />GND <br />GRS <br />HH <br />HOA <br />HP <br />IEEE <br />IG <br />KCMIL <br />KV <br />KVA <br />KW <br />KWH <br />LC <br />LS <br />LSIG <br />MAX <br />MCB <br />MCC <br />MDP <br />MIN <br />MH <br />MLO <br />MTS <br />N/A <br />NC <br />NEC <br />NEMA <br />N or NEUT <br />NFPA <br />NIC <br />NO <br />O/H <br />P <br />PA <br />PB <br />PC <br />PH <br />PT <br />RC <br />RSC <br />SEC <br />SPD <br />SW <br />SWBD <br />SWGR <br />TC <br />TEMP <br />TGB <br />TGMB <br />TTB <br />TV <br />TYP. <br />U/C <br />U/G <br />UGE <br />UL <br />UON <br />UPS <br />V <br />VFD <br />WG <br />WP <br />XFER <br />XFMR <br />DEFINITION <br />AMPS, AMPERE, AMPERAGE <br />ABOVE COUNTER <br />ALTERNATING CURRENT <br />AMERICANS WITH DISABILITIES ACT <br />ABOVE FINISHED FLOOR <br />ABOVE FINISHED GRADE <br />AMPERE INTERRUPTING CURRENT <br />ALUMINUM <br />AMERICAN NATIONAL STANDARD INSTITUTE <br />AUTOMATIC TRANSFER SWITCH CONTROL <br />AUTOMATIC TRANSFER SWITCH <br />AUDIO/VISUAL <br />AMERICAN WIRE GUAGE <br />BUILDING AUOTMATION SYSTEM <br />BELOW FINISHED CEILING <br />CONDUIT <br />CIRCUIT BREAKER <br />CLOSED CIRCUIT TELEVISION <br />CIRCUIT <br />CURRENT TRANSFORMER <br />COPPER <br />DIMMING OR DIMMER <br />DIGITAL CONTROLS <br />DISTRIBUTION BOARD <br />DIRECT CURRENT <br />DAY-LIGHTING <br />DISCONNECT SWITCH <br />EMERGENCY <br />ENCLOSED CIRCUIT BREAKER <br />ELECTRIC WATER COOLER <br />EXISTING <br />FUTURE <br />FIRE ALARM <br />FIRE ALARM CONTROL PANEL <br />FIRE ALARM TERMINAL CABINET <br />FEEDER <br />GENERATOR ALARM ANNUNCIATOR <br />GENERATOR ALARM PANEL <br />GENERATOR <br />GROUNDING ELECTRODE CONDUCTOR <br />GROUND FAULT INTERRUPTER <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GROUND FAULT EQUIPMENT PROTECTION <br />GROUND FAULT PROTECTION <br />GROUND <br />GALVANIZED RIGID STEEL <br />HAND HOLE <br />HAND-OFF AUTOMATIC <br />HORSEPOWER <br />INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS <br />ISOLATED GROUND <br />THOUSAND CIRCULAR MILS <br />KILOVOLT <br />KILOVOLT AMPS <br />KILOWATT <br />KILOWATT HOURS <br />LIGHTING CONTACTOR <br />LOUD SPEAKER <br />LONG TIME, SHORT TIME, INSTANTANEOUS AND GROUND <br />FAULT PROTECTION <br />MAXIMUM <br />MAIN CIRCUIT BREAKER <br />MOTOR CONTROL CENTER <br />MAIN DISTRIBUTION PANEL <br />MINIMUM <br />MAN HOLE <br />MAIN LUGS ONLY <br />MANUAL TRANSFER SWITCH <br />NOT APPLICABLE <br />NORMALLY CLOSED <br />NATIONAL ELECTRIC CODE <br />NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION <br />NEUTRAL <br />NATIONAL FIRE PROTECTION ASSOCIATION <br />NOT IN CONTRACT <br />NORMALLY OPEN <br />OVER HEAD <br />POLE <br />PUBLIC ADDRESS <br />PULL BOX <br />PHOTOCELL <br />PHASE POTENTIAL TRANSFORMER <br />POTENTIAL TRANSFORMER <br />RECEPTACLE CONTACTOR <br />RIGID STEEL CONDUIT <br />SECURITY <br />SURGE PROTECTIVE DEVICE <br />SWITCH <br />SWITCHBOARD <br />SWITCHGEAR <br />TIME CLOCK <br />TEMPORARY <br />TECHNOLOGY GROUND BAR <br />TECHNOLOGY MAIN GROUND BAR <br />TELEPHONE TERMINAL BOARD <br />TELEVISION <br />TYPICAL <br />UNDER COUNTER <br />UNDERGROUND <br />UNDERGROUND ELECTRIC <br />UNDERWRITERS' LABORATORIES <br />UNLESS OTHERWISE NOTED <br />UNINTERRUPTIBLE POWER SUPPLY <br />VOLTS, VOLTAGE <br />VARIABLE FREQUENCY DRIVE <br />WIRE GUARD <br />WEATHERPROOF <br />TRANSFER <br />TRANSFORMER <br />*** ARCHITECT TO APPROVE ALL FINISHES AND COLORS PRIOR TO RELEASE OF ORDER. <br />E2 UNIVERSAL 120/277 <br />EMERGI-LITE <br />DUAL-LITE <br />COMPASS <br />HE WILLIAMS <br />EXIT/EM/LED-R-WHT-SDT-120 <br />COMBINATION LED EXIT/EMERGENCY LIGHT, RED LETTERING, NiCd BATTERY, SELF DIAGNOSTIC TEST, <br />BUILT-IN TEST SWITCH, NUMBER OF FACES AS SHOWN ON PLAN RED LED 3.7 <br />* ALL INDOOR LIGHT FIXTURES ARE TO BE RATED FOR 2.5KA SURGE PROTECTION MINIMUM. <br />**ALL OUTDOOR LIGHT FIXTURES ARE TO BE RATED FOR 10KA SURGE PROTECTION MINIMUM. <br />XE2 UNIVERSAL 120/277 EXISTING FIXTURE TO REMAIN IN EXISTING LOCATION COMBINATION EXIT/EM FIXTURE WITH BATTERY BACK UP N/A 5 <br />XE2R UNIVERSAL 120/277 EXISTING RELOCATED EXISTING FIXTURE COMBINATION EXIT/EM FIXTURE WITH BATTERY BACK UP N/A 5 <br />ZR SURFACE 120/277 <br />DUAL LITE <br />LITHONIA <br />EMERGILITE <br />HE WILLIAMS <br />EMER/DECO-DBR-LT-D <br />DECORATIVE LED EMERGENCY LIGHT, MAINTENANCE FREE NiCd BATTERY, BUILT-IN TEST SWITCH SELF <br />DIAGNOSTIC WITH LOW TEMP OPTION LED 2.9 <br />XEM SURFACE 120/277 EXISTING FIXTURE TO REMAIN IN EXISTING LOCATION WALL MOUNTED EMERGENCY LIGHT N/A 5 <br />XEMR SURFACE 120/277 EXISTING RELOCATED EXISTING FIXTURE WALL MOUNTED EMERGENCY LIGHT N/A 5 <br />EM SURFACE 120/277 <br />EMERGI-LITE <br />DUAL-LITE <br />COMPASS <br />HE WILLIAMS <br />EMER/CP/ADJ/LED-WHT-120 <br />LED SURFACE MOUNTED EMERGENCY LIGHT WITH ADJUSTABLE HEADS, NiCD BATTERY, BUILT-IN TEST <br />SWITCH, FULLY AUTOMATIC SOLID-STATE SYSTEM, CHARGE RATE/POWER INDICATOR, UL 924 LISTED, <br />SUITABLE FOR DRY OR DAMP LOCATIONS <br />LED 2.1 <br />XBR RECESSED <br />(GRID)120/277 EXISTING RELOCATED EXISTING FIXTURE EXISTING 2 X 2 LAY-IN, 18 CELL PARABOLIC FLUORESCENT WITH INNER/OUTER BALLASTS N/A 48 <br />XC RECESSED 120/277 EXISTING FIXTURE TO REMAIN IN EXISTING LOCATION RECESSED FLUORESCENT CAN LIGHT N/A 42 <br />XCE RECESSED 120/277 EXISTING FIXTURE TO REMAIN IN EXISTING LOCATION SAME AS XC WITH EMERGENCY BALLAST-CONNECT TO LOCAL LIGHTING CIRCUIT N/A 43 <br />XA RECESSED <br />(GRID)120/277 EXISTING FIXTURE TO REMAIN IN EXISTING LOCATION EXISTING 2 X 4 LAY-IN, 18 CELL PARABOLIC FLUORESCENT WITH INNER/OUTER BALLASTS N/A 96 <br />XAR RECESSED <br />(GRID)120/277 EXISTING RELOCATED EXISTING FIXTURE EXISTING 2 X 4 LAY-IN, 18 CELL PARABOLIC FLUORESCENT WITH INNER/OUTER BALLASTS N/A 96 <br />XB RECESSED <br />(GRID)120/277 EXISTING FIXTURE TO REMAIN IN EXISTING LOCATION EXISTING 2 X 2 LAY-IN, 18 CELL PARABOLIC FLUORESCENT WITH INNER/OUTER BALLASTS N/A 48 <br />ORANGE COUNTY DSS FIXTURE SCHEDULE <br />SYMBOL SIZE / MOUNTING VOLT ACCEPTABLE <br />MANUFACTURERS MANUFACTURER AND MODEL NO.DESCRIPTION LAMP WATTS <br />B GROUND 120/277 KIM OR EQUAL <br />KIM <br />PA7R-CT-NU-3HS-12L-020-4K7-42A-GT-MW- <br />UNV <br />7" ROUND 42" HIGH ALUMINUM BOLLARD, NO UP-LIGHT, TYPE 3 WITH HOUSE SIDE SHIELD, MOTION <br />SENSING CONTROLS 50%/100% UNIVERSAL VOLTAGE, PROVIDE POLE BASES PER MANUFACTURER'S <br />INSTRUCTIONS <br />LED 2000 <br />LUMENS <br />4000K <br />22 <br />METHOD OF COMPLIANCE: <br />ELECTRICAL SYSTEM AND EQUIPMENT <br />PRESCRIPTIVE_____ PERFORMANCE_____X <br />LIGHTING SCHEDULE <br />Total wattage per fixture - Varies - See Fixture Schedule <br />Number of ballasts in fixture - See Specifications. <br />Ballast type used in the fixture - See Specifications. <br />Number of lamps in fixture - See Fixture Schedule. <br />Lamp type required in fixture - See Fixture Schedule. <br />2018 North Carolina State Building Code, Energy Conservation Code. <br />complies with the electrical system and equipment requirements of the <br />To the best of my knowledge and belief, the design of this building <br />DESIGNER STATEMENT: <br />___ 406.5 Provision of Dedicated Outdoor HVAC Air System <br />___ 406.4 On-Site Supply of Renewable Energy <br />___ 406.3 Enhanced Lighting Controls <br />___ 406.2 Reduced Lighting Power Density <br />___ 406.1 More Efficient HVAC Performance <br />ADDITIONAL PRESCRIPTIVE COMPLIANCE <br />Total exterior wattage specified versus allowed: <br />Total interior wattage specified versus allowed: <br />------- watts versus ------ <br />------- watts versus ------- <br />watts <br />watts (whole building) <br />ENERGY CODE: <br />PRESCRIPTIVE_____ PERFORMANCE_____ASHRAE 90.1: <br />___ 406.6 High Efficiency Service Water Heating <br />NO ADDITIONAL OR NEW LIGHT <br />FIXTURES WILL BE INSTALLED AS <br />PART OF THE SCOPE OF WORK. <br />TOTAL WATTAGE FOR SPACE IS <br />TO REMAIN AS IS. <br />1. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR FLOOR PLAN DIMENSIONS. DO <br />NOT SCALE THESE DRAWINGS. <br />2. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH OTHER TRADES INVOLVED <br />IN THE PROJECT, PRIOR TO THE INSTALLATION OF HIS EQUIPMENT SO AS TO AVOID CONFLICTS DURING <br />CONSTRUCTION AND ALLOW FOR OPTIMUM MAINTENANCE AND WORKING SPACE. <br />3. ALL LIGHT FIXTURES SHALL BE SUPPORTED INDEPENDENTLY OF THE SUSPENDED CEILING SYSTEM. <br />REFER TO THE SPECIFICATIONS FOR MORE DETAILED INFORMATION. <br />4. USE OF THE CONDUIT SYSTEM FOR EQUIPMENT GROUNDING SHALL NOT BE ACCEPTABLE. A SEPARATE <br />GREEN GROUND WIRE SHALL RUN WITH THE CIRCUIT CONDUCTORS IN EACH CIRCUIT. <br />5. IN ALL AREAS WHERE FIRE RATED WALLS, FLOORS AND CEILINGS ARE INSTALLED, ALL PENETRATIONS OF <br />ELECTRICAL CONDUITS OR OTHER RELATED ELECTRICAL MATERIAL SHALL BE PROPERLY SEALED WITH <br />APPROVED FIRE RATED MATERIALS TO MAINTAIN THE RATINGS OF THE BUILDING CONSTRUCTION. <br />6. ALL FUSES, DISCONNECT SWITCHES, AND BREAKER SIZES SHOWN FOR MECHANICAL/PLUMBING/FIRE <br />PROTECTION EQUIPMENT SHALL BE VERIFIED BEFORE THE PURCHASE OR INSTALLATION OF SAID <br />EQUIPMENT, WITH THE EQUIPMENT SUPPLIER AND MECHANICAL/PLUMBING CONTRACTOR. <br />7. ALL WORK AND MATERIAL SHALL BE PROVIDED IN ACCORDANCE WITH STATE, LOCAL AND NATIONAL <br />CODES AND ORDINANCES. <br />8. THE NEW FIRE ALARM EQUIPMENT SHOWN SHALL BE PROVIDED IN ACCORDANCE WITH THE <br />MANUFACTURER'S REQUIREMENTS. PROVIDE ALL WIRING AS REQUIRED FOR A COMPLETE SYSTEM. <br />9. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND FINISHES BEFORE PURCHASE OF <br />ANY LIGHT FIXTURES SO THAT THE PROPER TRIM WILL BE PROVIDED FOR THE CEILING TO BE INSTALLED. <br />ANY DIFFERENCES SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. <br />10. EACH CONTRACTOR SHALL PROVIDE HIS OWN SUPPORT OF ALL DEVICES AND EQUIPMENT PROVIDED BY <br />HIM AND SHALL SUPPORT SUCH EQUIPMENT PER APPROVED GOVERNING CODES OR PER APPROVAL OF <br />THE ENGINEER. UNACCEPTABLE WORKMANSHIP OR MATERIALS SHALL BE REPLACED AT THE REQUEST <br />OF THE ENGINEER AT THE CONTRACTOR'S EXPENSE. <br />11. ALL JUNCTION BOXES AND CONDUIT RUNS (WITH OR WITHOUT WIRES) SHALL BE COLOR CODED WITH <br />PAINT, IN ACCORDANCE WITH ELECTRICAL GENERAL PROVISIONS. <br />12. THE MOUNTING HEIGHTS AND LOCATIONS OF ALL WALL MOUNTED OUTLETS AND JUNCTION BOXES SHALL <br />BE REVIEWED AND COORDINATED WITH THE ARCHITECT AND OWNER PRIOR TO INSTALLATION, FOR USE <br />WITH THE ACTUAL EQUIPMENT, CASEWORK AND MILLWORK TO BE FURNISHED. <br />13. ALL WIRE AND CONDUIT SIZES ARE BASED ON 75°C THHN OR THWN WIRE UNLESS OTHERWISE NOTED. <br />14. ALL BRANCH BREAKERS SERVING EMERGENCY LIGHTS SHALL BE PROVIDED WITH BREAKER LOCK TO <br />PREVENT TURNING BREAKER OFF ACCIDENTALLY. <br />15. WHERE MULTIPLE SWITCHES ARE SHOWN IN THE SAME LOCATION THEY SHALL BE GANGED TOGETHER <br />IN ONE MULTIPLE GANG BOX WITH MATCHING COVER AND PARTITION (IF REQUIRED). THE ELECTRICAL <br />CONTRACTOR SHALL LOOK AT BOTH POWER AND LIGHTING PLAN TO DETERMINE WHICH SWITCH IS <br />APPLICABLE. <br />16. THE LOCATION OF ALL WALL MOUNTED DEVICES, INCLUDING MOUNTING HEIGHTS, SHALL BE FIELD <br />VERIFIED WITH THE ARCHITECT PRIOR TO INSTALLATION. <br />17. WHERE ELECTRICAL EQUIPMENT PENETRATES EXTERIOR W ALLS OR THE ROOF, THEY SHALL BE <br />PROPERLY SEALED WITH METHODS APPROVED BY THE ENGINEER. SUBMIT DETAIL OF PROPOSED <br />SEALING METHODS. <br />18. ALL EXTERIOR BUILDING LIGHTS AND EMERGENCY LIGHTING SHALL BE WIRED WITH #10 AWG. <br />19. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CHAIN HUNG FIXTURES <br />LOCATED IN MECHANICAL OR OTHER SPACES WITH OTHER TRADES, SO AS NOT TO CONFLICT WITH <br />OTHER EQUIPMENT. <br />20. ALL EMERGENCY LIGHTING, EXIT SIGNS AND NIGHT LIGHTS SHALL BE WIRED AHEAD OF ANY SWITCH <br />AND/OR BUILDING AUTOMATION SYSTEM. <br />21. WHERE CONDUIT OR OUTLET BOXES CANNOT BE INSTALLED IN EXISTING WALLS FOR NEW DEVICES, <br />THEN PROVIDE AND INSTALL SURFACE MOUNTED WIREMOLD RACEWAYS. CONFIRM ALL WIREMOLD WITH <br />ARCHITECT PRIOR TO INSTALLATION. <br />22. OUTLET BOXES ON OPPOSITE SIDES OF THE FIRE RESISTANT WALL OR SHAFT ENCLOSURE RATED TWO <br />HOURS OR LESS SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24" AS <br />REQUIRED BY NCSBC VOL 1 PARAGRAPH 705.4.3. <br />23. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS AS REQUIRED FOR ELECTRICAL CODE <br />COMPLIANCE AND TO ACCESS ANY INSTALLATION THAT WILL REQUIRE FUTURE MAINTENANCE. THESE <br />DOORS SHALL BE 20" X 20". EACH ROOM WITH A DRYWALL CEILING SHALL HAVE A MINIMUM OF ONE <br />ACCESS DOOR PROVIDED BY THE ELECTRICAL CONTRACTOR. THE DRYWALL SUBCONTRACTOR WILL <br />PROVIDE THE REQUIRED FRAMED OPENING AND INSTALL THE ACCESS DOORS. <br />24. CONDUCTORS FOR BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3% AT <br />THE FARTHEST OUTLET OF POWER, HEATING AND LIGHTING LOADS, OR ANY COMBINATION OF SUCH <br />LOADS. THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE <br />FARTHEST OUTLET SHALL NOT EXCEED 5%. <br />A. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 120V CIRCUIT EXCEED <br />50'-0" THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL NOT BE <br />SMALLER THAN #10AWG. INCREASE THE BRANCH CIRCUIT CONDUCTOR SIZE AN ADDITIONAL WIRE SIZE <br />FOR EACH ADDITIONAL 125' FOR THE ENTIRE CIRCUIT. THE GROUND CONDUCTOR SIZE SHALL BE <br />INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS AS PER NEC 2011 250.122 (B). <br />25. REFER TO FIRE ALARM DRAWINGS FOR FIRE ALARM WORK. <br />GENERAL NOTES <br />ELECTRICAL ENERGY FORM <br />SHEET INDEX - ELECTRICAL <br />Sheet Number Sheet Name Current Revision Current Revision Date <br />E0-00 LEAD SHEET <br />E0-01 DEMOLITION PLAN <br />E1-01 FIRST FLOOR PLAN - LIGHTING <br />E2-01 FIRST FLOOR PLAN - POWER <br />E2-02 PARTIAL POWER RISER <br />E3-01 FIRST FLOOR PLAN - FIRE ALARM <br />E3-02 FIRE ALARM RISER/MATRIX <br />E4-01 ELECTRICAL DETAILS <br />T 919 781 8582 <br />F 919 781 3979 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />DRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEIDThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETPDC #20033 <br />C:\Users\chris.pdc\Documents\20033_OCC Europa_MEP_Central_Model_chrishoo.rvt5/28/2020 3:43:28 PME0-00 <br />LEAD SHEET <br />2020045 21 MAY 2020CONSTRUCTION DOCUMENTSWCM <br />TDAORANGE COUNTY, NCDSS SKILLS DEVELOPMENT CENTER100 Europa Dr Ste 190, Chapel Hill, NC 2751705/28/2020 <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE