SPRINKLER HEAD/MATERIAL LEGEND <br />SPRINKLER DESIGN DATA <br />DESIGN SUMMARY <br />SHEET INDEX - FIRE PROTECTION <br />Sheet Number Sheet Name <br />FP0-00 FIRE PROTECTION ABBREVIATIONS, SYMBOLS & DETAILS <br />FP1-01 FIRE PROTECTION SPRINKLER PLAN <br />SEE BELOW <br />SEE BELOW <br />VARIES <br />Total Bldg. Hgt.: <br />Safety Factor: <br />Node # <br />Spacing <br />Design Area <br />Density <br />Requirements @ <br /># Design Sprklr's. <br />Hose Allowance <br />K-Factor <br />P.S.I. Req'd. <br />G.P.M. Req'd. <br />P.S.I. <br />G.P.M. <br />System Id No. <br />Design Method <br />Project Name: <br />Project Location: <br />Designed By: <br />Occupancy: <br />Location <br />Criteria From <br />Hazard Class <br />Type of System <br />Suite: <br /> Phone#: <br />Hazard: <br />System # 1 <br />MJS <br />Floor#: <br />(919) 790-9989 <br />SEE BELOW <br />SEE BELOW <br />Ceiling Hgt.: <br />Sys. Sq. Ft.: <br />System: <br />VARIES <br />Floor Plan:RENOVATION - ORANGE CO. SKILLS DEV. <br />EXISTING COMPLIANT SYSTEM <br />1. <br />NOTE: <br />100 <br />EXISTING <br />EXISTIING FIRST FLOOR / GROUND LEVEL <br />WET <br />225 MAX <br />0.10 GPM/SQ. FT. <br />NFPA 13 <br />5.6 <br />#1 <br />LIGHT HAZARD <br />COMMERCIAL <br />2. <br />3. <br />EXISTING FIRE SPRINKLER HEAD OUTLET TO BE USED TO FEED NEW PENDENT SPRINKLER HEAD. <br />NEW SEMI - RECESSED TYPE PENDENT SPRINKLER HEAD: QUICK-RESPONSE; GLASS BULB; ADJUSTABLE; CHROME <br />FINISH; WITH CHROME PLATED ESCUTCHEON; 1/2"/155°/SSP/K=5.6 <br />ALL SPRINKLER HEAD SPECIFICATION INFORMATION LISTED ABOVE IS TYPICAL UNLESS OTHERWISE INDICATED ON THE <br />DRAWINGS AND/OR AS OTHERWISE REQUIRED. BY CODE (ORIFICE SIZES, TEMPERATURE CLASSIFICATION, ETC.). <br />WET SPRINKLER SYSTEM PIPING TO BE BLACK STEEL PIPE, ASTM A 53 SCHEDULE 40 WITH THREADED OR GROOVED <br />JOINTS AS OUTLINE IN THE SPECIFICATIONS. <br />ALL SPRINKLER SYSTEM PIPING HANGERS ANDS SUPPORTS SHALL COMPLY WITH NFPA 13 AND INSTALLED ACCORDING <br />TO NFPA 13. <br />ORANGE COUNTY SKILLS DEVELOPMENT - EUROPA BUILDING <br />CHAPEL HILL, NORTH CAROLINA <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING <br />EXISTING RECESSED TYPE PENDENT SPRINKLER HEAD: QUICK-RESPONSE; GLASS BULB; ADJUSTABLE; CHROME FINISH; <br />WITH CHROME PLATED ESCUTCHEON; 1/2"/155°/SSP/K=5.6RS <br />6. <br />8. <br />7. <br />5. <br />4. <br />3. <br />2. <br />1. <br />11. <br />10. <br />9. <br />14. <br />13. <br />12. <br />15. <br />16. <br />REPAIR ANY DAMAGE TO FIRE PROOFING MATERIAL DUE TO INSTALLATION OF HANGERS AND SUPPORTS. <br />FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR PRODUCTION AND STAMP AND SIGNATURE <br />OF SYSTEM LAYOUT SHOP DRAWINGS DRAWINGS AND CALCULATIONS WHICH SHALL INCLUDE THE FIRE <br />PROTECTION CONTRACTORS NORTH CAROLINA FIRE SPRINKLER CONTRACTOR'S LICENSE AND THE <br />RESPONSIBLE INDIVIDUAL'S NAME AND NICET LEVEL. <br />ALL SPRINKLER PIPING, AS SHOWN, IS DIAGRAMMATIC WITH APPROXIMATE PIPE LOCATIONS, ELEVATIONS, <br />ROUTING, ETC., AND IS PROVIDED FOR INFORMATIONAL PURPOSES. EVERY FITTING, ELL, TEE AND LENGTH <br />OF PIPE MAY NOT BE SHOWN. IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW THE CONTRACT <br />DRAWINGS AND COORDINATE THE FIRE PROTECTION SYSTEM INSTALLATION WITH THE BUILDING <br />STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE FIRE PROTECTION CONTRACTOR SHALL <br />CREATE A FABRICATION DRAWING SHOWING ALL PIPE SIZES, LOCATION, ROUTING, HANGERS & <br />ELEVATIONS THAT IS A RESULT OF THIS COORDINATION EFFORT. NECESSARY OFFSETS IN PIPING <br />REQUIRED TO PROPERLY INSTALL THE FIRE PROTECTION SYSTEM AS TO TAKE UP MINIMUM SPACE SHALL <br />BE FURNISHED AND INSTALL BY THE CONTRACTOR WITH NO ADDITIONAL EXPENSE TO THE OWNER. <br />PROVIDE MIN. PITCH OF PIPE REQUIRED TO DRAIN SYSTEM. PITCH PIPE TOWARDS INSPECTOR'S TEST <br />STATION AND/OR MAIN RISER. PROVIDE MANUAL AIR VENTS AT HIGH POINTS OF SYSTEM TO EVACUATE <br />AIR FROM SYSTEM. <br />FIRE PROTECTION INSTALLATIONS SHALL MEET THE REQUIREMENTS OF NFPA 13, 2013 EDITION, AND ANY <br />STATE OR LOCAL AUTHORITY HAVING JURISDICTION. <br />ALL SPRINKLER HEADS SHALL BE LOCATED IN CENTER OF TILE WHERE LAY-IN CEILINGS OCCUR UNLESS <br />NOTED OTHERWISE. <br />NOT ALL SYMBOLS & ABBREVIATIONS SHOWN ON THIS DRAWING MAY BE USED FOR THIS PROJECT. <br />UNLESS OTHERWISE NOTED, EACH TRADE CONTRACTOR IS RESPONSIBLE FOR CUTTING, CORE DRILLING, <br />PATCHING, ETC. TO INSTALL HIS RESPECTIVE WORK. <br />COORDINATE WORK OF THIS TRADE WITH OTHER TRADE CONTRACTORS. <br />SEAL ALL PIPING AND/OR CONDUIT PENETRATIONS THROUGH FIRE RATED ASSEMBLIES (WALLS, <br />PARTITIONS, FLOORS, ETC.) IN ACCORDANCE WITH THE UL LISTED SYSTEMS. <br />SEAL ALL PIPING AND/OR CONDUIT PENETRATIONS THROUGH NON-RATED ASSEMBLIES (WALLS, <br />PARTITIONS, FLOORS, ETC.) TO REDUCE TRANSFER OF SOUND THROUGH THE ASSEMBLIES. GYPSUM <br />WALLBOARD "MUD" MAY BE USED FOR THIS PROCESS. <br />EXAMINE THE PROJECT SITE AND/OR CIVIL DRAWINGS TO BECOME FAMILIAR WITH SITE CONDITIONS. NO <br />ADDITIONAL COMPENSATION WILL BE GRANTED FOR FAILURE TO THOROUGHLY EXAMINE SITE <br />CONDITIONS TO DETERMINE THE EXACT SCOPE OF THIS PROJECT. <br />AREAS OF THE FACILITY, WHETHER INSIDE OR OUTSIDE OF THE PROJECT LIMITS, DAMAGED DUE TO <br />CONSTRUCTION ACTIVITIES SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE <br />OWNER. <br />COORDINATE / SCHEDULE ALL SHUTDOWNS OF EXISTING UTILITIES IN ADVANCE WITH THE OWNER. <br />UNLESS NOTED OTHERWISE, ALL SPRINKLER PIPING SERVING INDIVIDUAL SPRINKLER HEADS SHALL BE 1" <br />SCHEDULE 40 BLACK STEEL. <br />ALL EXPOSED PIPING AND FITTINGS SHALL BE PAINTED AS DIRECTED BY THE PROJECT <br />ARCHITECT. REFER TO THE SPECIFICATIONS FOR COMPLETE DIRECTION AND METHODS. <br />GENERAL NOTES <br />17.PROJECT AREA HAZARD CLASSIFICATIONS TO MEET NFPA 13, 2013 ED. REQUIREMENTS. <br />18.FIRE PROTECTION CONTRACTOR RESPONSIBLE FOR PRODUCTION AND STAMP AND SIGNATURE OF <br />SYSTEM LAYOUT SHOP DRAWINGS SHALL REVIEW STRUCTURAL DRAWINGS & ARCHITECT'S BUILDING <br />CODE SUMMARY FOR CONFIRMATION OF SEISMIC DESIGN CATEGORY & WHERE REQUIRED & SHALL <br />DESIGN THE SYSTEM SUPPORTS AS REQUIRED. <br />PIPE <br />FM APPROVED HANGER <br />THREADED HANGER ROD <br />LOCKING NUT <br />FM APPROVED <br />EXPANSION ANCHOR <br />CONCRETE STRUCTURE (SEE PLANS) <br />NEW OR EXISTING <br />STRUCTURAL <br />STEEL MEMBER <br />F.M. APPROVED C-CLAMP <br />WITH <br />LOCKNUT. <br />THREADED HANGER ROD <br />FM APPROVED <br />SWIVEL <br />RING HANGER <br />EXTEND HANGER ROD AS <br />SHOWN FOR APPLICATIONS <br />WHERE PRESSURE <br />EXCEEDS <br />100 PSI. (SEE GEN. NOTE 1). <br />TYP. SPRINKLER PIPING <br />NOTE: <br />1. THESE METHODS SHALL BE USED WHEN PRESSURE EXCEEDS 100 PSI & SHALL <br />BE INSTALLED WITHIN 12" OF THE LAST SPRINKLER DROP ON EACH SPRINKLER <br />BRANCH LINE; ALL INSTALLATION SHALL COMPLY WITH NFPA 13. <br />SUSPENDED CEILING <br />VARIES <br />BRANCHLINE <br />OUTLET <br />THREADED <br />1" TEE OR <br />1" <br />PLANS FOR TYPE <br />VARIES <br />1"x 1/2" REDUCER <br />SPRINKLER HEAD; SEE <br />FIGURE 8-6.5.1.2(b) <br />OBSTRUCTIONS <br />AGAINST WALLS <br />(SSU/SSP).FOR SI UNITS: 1 IN. = 25.4 MM; 1 FT. = 0.3048 M. <br />ELEVATION VIEW <br />A >[(D-8 IN. (0.2m)] + B <br />D <30 IN. (0.8m) <br />WALL <br />DA <br />FIGURE 8-6.5.1.2(a) POSITION OF <br />SPRINKLERS TO AVOID OBSTRUCTIONS <br />TO DISCHARGE (SSU/SSP). <br />1 FT. TO LESS THAN 1 FT. 6 IN. <br />1 FT. 6 IN. TO LESS THAN 2 FT. <br />3 FT. 6 IN. TO LESS THAN 4 FT. <br />4 FT. TO LESS THAN 4 FT. 6 IN. <br />2 FT. TO LESS THAN 2 FT. 6 IN. <br />2 FT. 6 IN. TO LESS THAN 3 FT. <br />3 FT. TO LESS THAN 3 FT. 6 IN. <br />4 FT. 6 IN. TO LESS THAN 5 FT. <br />5 FT. AND GREATER <br />LESS THAN 1 FT. <br />12 IN. <br />14 IN. <br />18 IN. <br />0 IN. <br />OBSTRUCTION <br />ELEVATION VIEW <br />OBSTRUCTION <br />B <br />A <br />B <br />CEILING <br />21_ <br />2 IN. <br />31_ <br />2 IN. <br />51_ <br />2 IN. <br />71_ <br />2 IN. <br />91_ <br />2 IN. <br />161_ <br />2 IN. <br />DISTANCE FROM SPRINKLER <br />TO <br />SIDE OF OBSTRUCTION (A) <br />MAXIMUM ALLOW- ABLE <br />DISTANCE OF DEFLECTOR <br />ABOVE <br />BOTTOM OF OBSTRUCTION (B) <br />POSITION OF SPRINKLERS TO AVOID <br />OBSTRUCTIONS TO DISCHARGE <br />(SSU/SSP) <br />TABLE 8-6.5.1.2 CEILING <br />PATCH FOR <br />LARGER THAN 3" <br />PATCH FOR OPNG <br />2 LAYERS OF GB AT 2-HR WALLS. <br />PERMITTED TO PENETRATE WALLS. <br />FOAM GLASS INSULATION IS ONLY INSULATION MATERIAL <br />MAX SPACE AROUND OBJECT AND NEW PATCH SHALL BE %%131". <br />ALL PATCHES TO BE SET IN FULL BED OF DRYWALL COMPOUND. <br />ALL SCREW HEADS SHALL BE LEFT EXPOSED. <br />ALL SCREWS SHALL BE SPACED 3" O.C. MAX. <br />6. <br />FIRE PROOFING MATERIAL <br />C OF STUDS (TYP.) <br />CEILING LINE <br />NOTES: <br />1. <br />5. <br />4. <br />3. <br />2. <br />EXIST DUCT <br />AT DECK (TYP.) <br />TYPE 'G' SCREWS (TYP.) <br />TYPE 'G' SCREWS (TYP.) <br />TYPE 'S' SCREWS 8" O.C. <br />TYPE 'S' SCREWS (TYP.) <br />PATCH FOR <br />OR LESS <br />OPNG 3" <br />L <br />T 919 781 8582 <br />F 919 781 3979 <br />4600 Lake Boone Trail <br />Suite 205 <br />Raleigh, NC 27607 <br />info@smithsinnett.com <br />DRAWN BY: <br />CHECKED BY: <br />DESCRIPTIONDATEIDThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETPDC #20033 <br />C:\Users\chris.pdc\Documents\20033_OCC Europa_MEP_Central_Model_chrishoo.rvt5/20/2020 3:16:54 PMF0-00 <br />FIRE PROTECTION <br />LEAD SHEET <br />2020045 21 MAY 2020CONSTRUCTION DOCUMENTSWSM <br />MJSORANGE COUNTY, NCDSS SKILLS DEVELOPMENT CENTER100 Europa Dr Ste 190, Chapel Hill, NC 27517NOT TO SCALE <br />TYPICAL PIPE HANGER INSTALLATION3 <br />NOT TO SCALE <br />TYPICAL RETURN BEND2NOT TO SCALE <br />TYPICAL SPRINKLER AT SOFFIT INSTALLATION4 <br />NOT TO SCALE <br />TYPICAL WALL PENETRATION PATCHES1 <br />05/20/2020 <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE