Browse
Search
2020-598-E AMS-Muter Construction Europa upfit SDC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-598-E AMS-Muter Construction Europa upfit SDC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2021 1:20:38 PM
Creation date
8/30/2021 1:11:58 PM
Metadata
Fields
Template:
BOCC
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
475
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TOILET105ORIENTATIONROOM104NURSETRAINING106YOUTHCOUNCELOR107GENERALCLASSROOM111YOUTHCENTER108STORAGE109BREAKROOM110STAIRSXX5WIOA116FNS115MANAGER114GAL124GAL123SKILLSDEV.COMP. LAB120IT119DURHAMTECH121TOILET112RESOURCES101CSGB117VETERANS&PARTNERS122ON-SITEMANAGER102INTERVIEWROOM103A4-102CLO111ANO WORK IN THIS AREACONFERENCE118OPENOFFICE113CORRIDOR125CORRIDOR126RECEPTION1001105106112120122121S4UAS4UAS4UAS4UAS4UAS4UAS4UAS4UAS4UAS4UAS4UA22' - 5 3/4"19' - 4"6' - 0"3' - 8"1' - 0"5' - 0"11111121INFILL CASED OPENING WITH DOORSALVAGED WINDOWEW-14' - 0"S4UA1101S4UA1' - 6"5' - 0 5/8"29' - 4 1/2"CEILING MOUNTED HOSPITAL CURTAIN (4)3' - 4"2' - 10"1' - 3"3' - 4"EXISTING FURNITURE TO REMAIN IN PLACE3" CLEAR8"14'-5"4'-0"RELOCATED FIRE EXTINGUISHER CABINET1' - 6"EXISTING CASEWORKS4PB3' - 1 29/128"MECHXX2ELECXX1WOMEN'SXX3MEN'SXX4CORR.XX6ELEVXX7STAIRXX8ALTERNATE 1: EXTERIOR CONCRETE WALKWAY -5' WIDE, CONROL JOINTS EVERY 5'. INCLUDES SURFACE PREP. SEE DETAILS.END NEW SIDEWALK WITH ISOLATION JOINT AT EXISITNG WALKWAY20' - 9 185/256"64' - 8 181/256"VERIFY IN FIELD102' - 0 109/128"KEY NOTES:1. DEMOLISHED FULL HEIGHT DOOR INFILL. 2. DEMOLISHED FULL HEIGHT WINDOW INFILL. 3. NEW CASEWORK - SEE A4-10NOTES:1. WALL DIMENSIONS ARE TO FACE OF METAL STUD, DOORS NOT DIMENSIONED ARE TYPICALLY 4" FROM INTERSECTING WALL.2. ALL METAL STUD WALLS TERMINATING AT BOTTOM OF DECK ARE TO PROVIDE A DEFLECTION TRACK SECURED TO THE UNDERSIDE OF THE DECKING, NEST TOP TRACK BUT DO NOT ATTACH TO DEFLECTION TRACK. FILL FLUTE IN METAL DECK WHERE REQUIRED.3. ALL WALLS WHICH EXTEND TO DECK AND ARE BRACED TO DECK AT HEAD ON ALTERNATE STUDS, UNLESS OTHERWISE NOTED.4. SEE FINISH SCHEDULE FOR WALL, FLOOR, BASE, AND CEILING TYPES AND FINISHES.5. FURNITURE AND EQUIPMENT SHOWN DASHED ON PLANS IS NOT IN CONTRACT (NIC). GC TO PROVIDE WOOD BLOCKING FOR ALL WALL/CEILING MOUNTED ACCESSORIES.6. FIELD VERIFY FINAL ROOM DIMENSIONS PRIOR TO CASEWORK FABRICATION.FTYPAS SCHEDULEDTYPAS SCHEDULEDN8"6"T3' - 6"VARIES2' - 8"S4UAMARKPLAN SYMBOLDESCRIPTIONUL DESIGN #3 5/8" METAL STUD WITH ONE LAYER 5/8" GYP BOARD EACH SIDE UP TO BOTTOM OF DECKWALL TYPE LEGEND3 5/8" METAL STUD WITH 5/8" GYP BOARD ON ONE SIDE UP TO 8" ABOVE CEILINGNON-RATEDNON-RATED3 5/8" METAL STUD WITH TWO LAYERS 5/8" GYP BOARD EACH SIDE UP TO MIN. 8" ABOVE CEILINGNON-RATEDPLAN DETAIL5/8" GYP WALL BOARD3 5/8" MTL STUD SYSTEM AT 16" OCBATT INSULATION5/8" GYP WALL BOARD3 5/8" MTL STUD SYSTEM AT 16" OCBATT INSULATION5/8" GYP WALL BOARD3 5/8" MTL STUD SYSTEM AT 16" OCS4PAS4PB8' - 9"5' - 0"5 7/8"8 1/4"10 1/4"3 5/8"6"8"5/8" GWB ON METAL STUDSBATT INSULATION WHERE APPLICABLE -SEE WALL TYPESDOUBLE STUD @ JAMBBOX HEADER @ HEAD1/2" BOTH SIDES, TYP.5 7/8"8 1/4"10 1/4"3 5/8"6"8"5/8" GWB ON METAL STUDSDOUBLE STUD @ JAMBBOX HEADER @ HEAD1/2" BOTH SIDES, TYP.BATT INSULATION WHERE APPLICABLE -SEE WALL TYPESATTACH TOP AND BOTTOM TRACKS ALONG TOP AND FLANGE OF TRACK WITH (2) #10-18 SCREWS AT 8" O.C.UNPUNCHED STUDS, SIZE AND GAGE PER SCHEDULETOP AND BOTTOM TRACK GAGE SHALL MATCH HEADER GAGE PER SCHEDULEFULL HEIGHT JACK STUDS, REFER TO HEADER SCHEDULE FOR QUANTITY2" X 2" X 16 GAGE CLIP ANGLES 1/2" LESS THAN STUD WIDTH, ATTACH WITH (3) #10 SCREWS ON EACH LEG TO HEADER AND JAMB STUDSJAMB STUDS, REFER TO HEADER SCHEDULE FOR QUANTITYNON-LOAD BEARING HEADERTYPICAL FOR ALL INTERIOR DOORS UNLESS DIMENSIONED OTHERWISE DOOR, SEE PLAN AND DOOR SCHEDULE 4"T 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comDRAWN BY:CHECKED BY:DESCRIPTIONDATEIDThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETC:\Users\Drew\Documents\2020045_OC DSS Skills Europa_Arch_dwilgus@smithsinnett.com.rvt5/26/2020 12:22:19 AMA1-01FIRST FLOOR PLAN2020045 20 May 2020CONSTRUCTION DOCUMENTSMA, DWDWORANGE COUNTY, NCDSS SKILLS DEVELOPMENT CENTER UPFIT100 Europa Dr Ste 101, Chapel Hill, NC 27517REGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT1/8" = 1'-0"A1-011FIRST FLOOR PLANDOOR SCHEDULEDOORFRAMEHARDWARE SET(ALL EST.)FIRE RATING REMARKSMARKDOOR SIZEMAT TYPE (ALL EST.) LVS MAT TYPE (ALL EST.)DETAILSWIDTH HEIGHT THKHEAD JAMB THRESH105 3' - 0" 8' - 10" 1 3/4" SCWD F HM--106 3' - 0" 8' - 10" 1 3/4" SCWD V HM110 3' - 0" 8' - 10" 1 3/4" SCWD V HM112 3' - 0" 8' - 10" 1 3/4" SCWD F HM--120 3' - 0" 8' - 10" 1 3/4" SCWD V HM121 3' - 0" 8' - 10" 1 3/4" SCWD V HM122 3' - 0" 8' - 10" 1 3/4" SCWD V HM1/4" = 1'-0"DOOR TYPESEW-1NEW WINDOW - SALVAGED FROM EXISTING1 1/2" = 1'-0"A1-013HM HEAD AT STUD WALL1 1/2" = 1'-0"A1-014HM JAMB AT STUD WALL1/2" = 1'-0"A1-015TYPICAL INTERIOR HEADER - MTL STUD1 1/2" = 1'-0"A1-016TYPICAL DOOR PLACEMENT - MTL STUDDocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE
The URL can be used to link to this page
Your browser does not support the video tag.