Orange County NC Website
DSS Skills Development Center Smith Sinnett / 2020045 <br />Chapel Hill, North Carolina Orange County <br /> <br />MANUFACTURED PLASTIC LAMINATE CLAD CASEWORK 12 32 16 - 2 <br />C. Samples: For each exposed product and for each color and texture specified. <br />1. Submit samples of casework manufacturer’s standard decorative laminate colors, patterns, and <br />textures for exposed and semi-exposed materials for architect’s selection. Samples to other <br />materials or hardware shall be made available if requested. <br />2. Architect may request representative full-size samples for evaluation prior to approval. Samples <br />may be impounded by architect/owner until completion of project to ensure compliance with <br />specifications. <br />D. Production Drawings: <br />1. Submit production drawings for casework systems and countertops showing layout, elevations, <br />ends, cross-sections, face modular values, service run spaces and location of services. <br />2. Include layout of units with relation to surrounding walls, doors, windows, and other building <br />components. <br />E. Coordination Drawings: <br />1. Coordinate production drawings with other work involved. <br />F. Qualification Data: For qualified Installer and manufacturer. <br />G. Product Test Reports: Based on evaluation of comprehensive tests performed by manufacturer and <br />witnessed by a qualified testing agency. <br />1.6 QUALITY ASSURANCE <br />A. Manufacturer Qualifications: Modern plant with proper tools, dies, fixtures and skilled workmen to <br />produce high quality laboratory casework and equipment, and shall meet the following minimum <br />requirements: <br />1. Minimum of ten years experience in manufacture of wood or plastic laminate laboratory casework. <br />2. Ten installations of equal or larger size. <br />B. Installer Qualifications: Factory certified by the manufacturer. <br />C. Source Limitations: All casework, work surfaces, service fittings, and accessory equipment shall be <br />supplied by a single laboratory casework dealer. <br />D. Manufactured casework systems must conform to design, quality of materials, workmanship and function <br />as shown on drawings and specified herein. In the absence of a printed specification, minimum quality <br />standard shall be in accordance with AWI Section 1600B, Sixth Edition, Version 1.1, no exceptions will <br />be permitted; additional requirements shall be as specified herein. <br />1.7 DELIVERY, STORAGE, AND HANDLING <br />A. Deliver laminate clad casework and countertops only after wet operations in building are completed. <br />B. Store completed laminate clad casework and countertops in a ventilated place, protected from the <br />weather, with relative humidity range of 20% to 50%. <br />C. Protect finished surfaces from soiling and damage during handling and installation. Keep covered with a <br />protective covering. <br />1.8 PROJECT CONDITIONS <br />A. Weather Limitations: Advise contractor of requirements for maintaining heating, cooling and ventilation <br />in installation areas as required to reach relative humidity necessary to maintain optimum moisture <br />content. <br />B. Field Measurements: Verify actual room and opening dimensions by field measurements before <br />fabrication. <br />1.9 WARRANTY <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE