Browse
Search
2020-598-E AMS-Muter Construction Europa upfit SDC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-598-E AMS-Muter Construction Europa upfit SDC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2021 1:20:38 PM
Creation date
8/30/2021 1:11:58 PM
Metadata
Fields
Template:
BOCC
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
475
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DSS Skills Development Center Smith Sinnett / 2020045 <br />Chapel Hill, North Carolina Orange County <br /> <br />GYPSUM BOARD 09 29 00 - 6 <br />3.4 INSTALLING STEEL FRAMING FOR WALLS AND PARTITIONS <br />A. Install runners (tracks) at floors, ceilings, and structural walls and columns where gypsum board stud <br />assemblies abut other construction. <br />1. Where studs are installed directly against exterior walls, install asphalt felt strips or foam gaskets <br />between studs and wall. <br />B. Installation Tolerances: Install each steel framing and furring member so that fastening surfaces do not <br />vary more than 1/8 inch from the plane formed by the faces of adjacent framing. <br />C. Extend partition framing full height to structural supports or substrates above suspended ceilings, except <br />where partitions are indicated to terminate at suspended ceilings. Continue framing over frames for doors <br />and openings and frame around ducts penetrating partitions above ceiling to provide support for gypsum <br />board. <br />1. Cut studs ½ inch short of full height to provide perimeter relief. <br />2. For STC-rated and fire-resistance-rated partitions that extend to the underside of floor/roof slabs <br />and decks or other continuous solid structural surfaces to obtain ratings, install framing around <br />structural and other members extending below floor/roof slabs and decks, as needed, to support <br />gypsum board closures needed to make partitions continuous from floor to underside of solid <br />structure. <br />D. Install steel studs and furring in sizes and at spacings indicated. <br />1. Single-Layer Construction: Space studs 16 inches o.c., unless otherwise indicated. <br />2. Multilayer Construction: Space studs 16 inches o.c., unless otherwise indicated. <br />E. Install steel studs so flanges point in the same direction and leading edge or end of each gypsum board <br />panel can be attached to open (unsupported) edges of stud flanges first. <br />F. For curved partitions, install steel framing as follows: <br />1. Cut top and bottom runners through leg and web at 2-inch intervals for arc length. In cutting <br />lengths of runners, allow for uncut straight lengths of not less than 12 inches at ends of arcs. <br />2. Bend runners to uniform curve of radius indicated and locate straight lengths so they are tangent to <br />arcs. <br />3. Support outside (cut) leg of runners by clinching a 1-inch- high-by-0.0209-inch- thick steel sheet <br />strip to inside of cut legs using metal lock fasteners. <br />4. Attach runners to structural elements at floor and ceiling with fasteners located 2 inches from ends <br />and spaced 24 inches o.c. <br />G. Frame door openings to comply with GA-219, and with applicable published recommendations of <br />gypsum board manufacturer, unless otherwise indicated. Attach vertical studs at jambs with screws either <br />directly to frames or to jamb anchor clips on door frames; install runner track section (for cripple studs) at <br />head and secure to jamb studs. <br />1. Install double 20-gage studs at each jamb, unless otherwise indicated. <br />2. Install cripple studs at head adjacent to each jamb stud, with a minimum ½-inch clearance from <br />jamb stud to allow for installation of control joint. <br />H. Frame openings other than door openings to comply with details indicated or, if none indicated, as <br />required for door openings. Install framing below sills of openings to match framing required above door <br />heads. <br />3.5 APPLYING AND FINISHING PANELS, GENERAL <br />A. Comply with ASTM C 840. <br />B. Install ceiling panels across framing to minimize the number of abutting end joints and to avoid abutting <br />end joints in central area of each ceiling. Stagger abutting end joints of adjacent panels not less than one <br />framing member. <br />C. Install sound-attenuation blankets, where indicated, prior to installing gypsum panels unless blankets are <br />readily installed after panels have been installed on one side. <br />D. Attach gypsum panels to steel studs so leading edge or end of each panel is attached to open <br />(unsupported) edges of stud flanges first. <br />E. Attach gypsum panels to framing provided at openings and cutouts. <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE
The URL can be used to link to this page
Your browser does not support the video tag.