Browse
Search
2020-598-E AMS-Muter Construction Europa upfit SDC
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2020
>
2020-598-E AMS-Muter Construction Europa upfit SDC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2021 1:20:38 PM
Creation date
8/30/2021 1:11:58 PM
Metadata
Fields
Template:
BOCC
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
475
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Orange County Southern Expansion Smith Sinnett / 2017027 <br />Phase 1 – Seymour Center Renovation and Addition Orange County <br /> <br />GLAZING 08 80 00 - 6 <br />3. Overall Unit Thickness and Thickness of Each Lite: Dimensions indicated for insulating-glass <br />units are nominal and the overall thicknesses of units are measured perpendicularly from outer <br />surfaces of glass lites at unit's edge. <br />a. Performance Classification per ASTM E 774: Class A. <br />b. Thickness of Each Pane: 1/4". <br />c. Air Space Thickness: 1/2". <br />d. Sealing System: Dual seal, primary and secondary sealant: manufacturer's standard. <br />e. Spacer Material: Manufacturer's standard metal. <br />f. Dessicant: Manufacturer's standard; either molecular sieve or silica gel or blend of both. <br />g. Corner Construction: Manufacturer's standard corner construction. <br />4. Sealing System: Dual seal, with primary and secondary sealants as follows: <br />a. Manufacturer's standard sealants. <br />5. Spacer Specifications: Manufacturer's standard spacer material and construction. <br />2.3 INSULATING-GLASS UNITS <br />A. Solar Control Tinted Low-E Insulating-Glass Units: Manufacturer's standard units complying with the <br />following requirements (use tempered or heat strengthened where shown on the drawings and required by <br />the manufacturer and the NC Building Code): <br />1. Insulating Glass: PPG Commercial 1” Solarban 70xl (2) Tinted Insulating Glass Unit or approved <br />equal. <br />2. Exterior Pane: Tinted heat strengthened glass. <br />3. Interior Pane: Clear heat strengthened glass with Low-E high performance sputter coat on #2 <br />surface. <br />4. Overall Unit Thickness & Thickness Each Lite: 1/4” glass panes and ½” air space. Overall <br />thickness 1”. <br />5. Interspace Content: Air. <br />6. Tint Color: Selected from Manufacturers standard glass tint. Basis of Design is PPG Tint Color <br />“Solexia” <br />7. Kind: HS (heat strengthened). <br />8. Visible Transmittance: 58% <br />9. Summer U Value: 0.26 <br />10. Winter U Value: 0.28 <br />11. Shading Coefficient: 0.31 <br />12. Solar Heat Gain: 0.27 <br />13. Outdoor Visible Reflectance: 10 <br />B. Translucent Glazing: At areas indicated, provide insulating glass units as specified with the addition of a <br />translucent inner core material that is compatible with the insulating glass unit. <br />2.4 INSULATED GLAZED SPANDREL PANELS <br />A. Insulated Glazed Spandrel Panels: Provide Manufacturer's standard sealed insulated glazed panels as <br />indicated on drawings color as selected by architect. Panels shall be 1" total thickness with 1/4" heat <br />strengthened lites each side. <br />2.5 GLAZING GASKETS <br />A. Dense Compression Gaskets: Molded or extruded gaskets of material indicated below, complying with <br />standards referenced with name of elastomer indicated below, and of profile and hardness required to <br />maintain watertight seal: <br />1. Neoprene, ASTM C 864. <br />2. EPDM, ASTM C 864. <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE
The URL can be used to link to this page
Your browser does not support the video tag.