Orange County NC Website
DSS Skills Development Center Smith Sinnett / 2020045 <br />Chapel Hill, North Carolina Orange County <br /> <br />FLUSH WOOD DOORS 08 14 16 - 5 <br />B. Installation Instructions: Install doors to comply with manufacturer's written instructions and the <br />referenced quality standard, and as indicated. <br />1. Install fire-rated doors in corresponding fire-rated frames according to NFPA 80. <br />C. Job-Fitted Doors: Align and fit doors in frames with uniform clearances and bevels as indicated below; <br />do not trim stiles and rails in excess of limits set by manufacturer or permitted for fire-rated doors. <br />Machine doors for hardware. Seal edges of doors, edges of cutouts, and mortises after fitting and <br />machining. <br />1. Clearances: Provide 1/8 inch at heads, jambs, and between pairs of doors. Provide 1/8 inch from <br />bottom of door to top of decorative floor finish or covering unless otherwise indicated. Where <br />threshold is shown or scheduled, provide 1/4 inch from bottom of door to top of threshold unless <br />otherwise indicated. <br />a. Comply with NFPA 80 for fire-rated doors. <br />2. Bevel non-fire-rated doors 1/8 inch in 2 inches at lock and hinge edges. <br />3. Bevel fire-rated doors 1/8 inch in 2 inches at lock edge; trim stiles and rails only to extent <br />permitted by labeling agency. <br />D. Factory-Fitted Doors: Align in frames for uniform clearance at each edge. <br />E. Factory-Finished Doors: Restore finish before installation if fitting or machining is required at Project <br />site. <br />1. Factory Finish doors to comply with AWI finish TR6 (AWI #5) and provide stain color as selected <br />by Architect. Factory finishing shall comply with Section 1500 AWI - 7th Edition 1997. Provide <br />12" X 12" door samples with final stain and finish selection. Doors shall match final approved <br />sample. <br />3.3 ADJUSTING <br />A. Operation: Rehang or replace doors that do not swing or operate freely. <br />B. Finished Doors: Replace doors that are damaged or that do not comply with requirements. Doors may be <br />repaired or refinished if work complies with requirements and shows no evidence of repair or refinishing. <br />END OF SECTION 08 14 16 <br />DocuSign Envelope ID: ECCAC5A0-6CC8-4B37-8AD3-89D69F0AE1AE