Browse
Search
2021-439-E-AMS-Siemens Industry-Southern Human Services HVAC Controls
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-439-E-AMS-Siemens Industry-Southern Human Services HVAC Controls
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2021 3:03:35 PM
Creation date
8/9/2021 3:00:16 PM
Metadata
Fields
Template:
Contract
Date
8/5/2021
Contract Starting Date
8/5/2021
Contract Ending Date
8/7/2021
Contract Document Type
Agreement
Amount
$205,450.00
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHSC HVAC and Roof Replacement Smith Sinnett / 2020072 <br />Orange County, North Carolina <br /> <br />SELECTIVE ROOF AND STRUCTURE DEMOLITION 02 07 00 - 5 <br />B. Metal Deck replacement: Deteriorated or damaged areas greater than 12” but less than 24” square sor <br />diameter shall be repaired with decking. Decking shall be sized to extend a minum of 12” beyond the size <br />of the deficient area. Nest new deck and secure to existing deck with fasteners, spaced 3” per side equally <br />spaced and one in each flute. <br />C. Metal Deck Replacement (larger areas): Deteriorated or damaged areas greater that 24” square or <br />diameter shall be repaired with metal deck. Replacement deck shall extend a minimum of three spans. <br />Permanently anchor units to joists and fasten side laps by the end of each working day. At a minimum, <br />fasten every rib at all supports and 6” o.c. along laps at perimeters and corners. <br />D. Immediately after placement and alignment, and after correcting innacuracies, permanently fasten steel <br />deck units to structural supports and to adjacent deck units with screws at 8” o.c. Attachment of adjacent <br />deck units by bottom punching is prohibited. <br />3.8 METAL DECK RESTORATION <br />A. Wire brush and sweep all loose rust from affected area. Areas of deck evidencing pinholes shall be <br />replaced in accordance with the requirements of this section. <br />B. Install one coat of rust inhibitor to affected area <br />C. Allow area to dry before proceeding with roof system installation. <br /> <br /> <br />END OF SECTION 02 07 00 <br />DocuSign Envelope ID: 17058488-BE46-4277-9E77-433E3054E269
The URL can be used to link to this page
Your browser does not support the video tag.