Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Southern Human Services Center Smith Sinnett /2020072 <br />HVAC and Roof Renovations Orange County,North Carolina <br />Power Conductors and Cables 26 05 19 - 3 <br />3)Phase C: Yellow. <br />4)Neutral/Grounded: Gray. <br />b.208Y/120 V,3 Phase,4 Wire System: <br />1)Phase A: Black. <br />2)Phase B: Red. <br />3)Phase C: Blue. <br />4)Neutral/Grounded: White. <br />c.Equipment Ground,All Systems: Green. <br />d.0 -10V Dimming conductors:Violet and Grey <br />2.03 BUILDING WIRE <br />A.Approved Manufacturers as listed below or approved equal: <br />1.Copper or Aluminum Building Wire: <br />a.Triangle <br />b.Okonite <br />c.Houston Wire and Cable <br />d.or approved equal <br />B.Description: Single conductor insulated wire. <br />C.Conductor Stranding: <br />1.Feeders and Branch Circuits: <br />a.Size 10 AWG and Smaller: Solid. <br />b.Size 8 AWG and Larger: Class B Stranded. <br />2.Control Circuits: Stranded. <br />D.Insulation Voltage Rating: 600 V. <br />E.Insulation: <br />1.Copper Building Wire: Type THHN/THWN or XHHW-2. <br />2.Conductors routed on roofs or other exterior surface where raceway is exposed to direct <br />sunlight shall be type XHHW-2 insulation. <br />3.Aluminum Building Wire (only where specifically indicated or permitted for substitution): Type <br />XHHW-2. <br />2.04 WIRING CONNECTORS <br />A.Description: Wiring connectors appropriate for the application,suitable for use with the conductors <br />to be connected,and listed as complying with UL 486A-486B or UL 486C as applicable. <br />B.Connectors for Grounding and Bonding: Comply with Section 26 05 26. <br />C.Wiring Connectors for Splices and Taps: <br />1.Splices or taps shall not be allowed for feeder conductors unless specifically noted on plans. <br />2.Where a splice or tap for feeder conductors is noted on the plans,connectors shall be <br />Blackburn insulated multi-tap or approved equal. <br />3.Splices in branch circuit conductors shall be allowed in accessible junction boxes,troughs,or <br />gutters. <br />a.Copper Conductors #10 AWG and smaller: Use twist-on insulated spring connectors. <br />b.Copper Conductors #8 AWG and larger: Use mechanical connectors with gum rubber <br />tape or friction tape.Solderless mechanical connectors with UL listed insulating covers <br />may be used at contractor's option. <br />4.Use of split bolts is not allowed. <br />5."Sta-kon"or other permanent type crimp connectors shall not be used for branch circuit <br />connections. <br />D.Wiring Connectors for Terminations: <br />1.Provide terminal lugs for connecting conductors to equipment furnished with terminations <br />designed for terminal lugs. <br />2.Provide compression adapters for connecting conductors to equipment furnished with <br />mechanical lugs when only compression connectors are specified. <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6