Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Southern Human Services Center Smith Sinnett /2020072 <br />HVAC and Roof Renovations Orange County,North Carolina <br />HVAC Ducts and Casings 23 31 00 - 6 <br />I.Support coils,filters,air terminals,dampers,sound attenuating devices,or other devices installed <br />in duct systems with angles or channels and make all connections to such equipment including <br />equipment furnished by others. Secure frames with gaskets,nuts,bolts and washers. <br />J.Flexible ducts shall not exceed 5 feet in length.Bends,kinks,and sagging of flexible duct will not <br />be accepted.The maximum permitted sag is 1/2"per foot of support spacing. <br />K.Install outside air intake duct to pitch down at minimum 1”per 20 ft toward intake louver or plenum <br />and to drain to outside of building. Solder or seal seams to form watertight joints. <br />L.Where 2 different metal ducts meet,install joint in such a manner that metal ducts do not contact <br />each other by using proper gasket seal or compound. <br />M.Flexible Ducts: Connect to metal ducts with adhesive plus sheet metal screws. <br />1.Flexible ducts are not allowed for special exhaust systems,such as laboratory exhaust, <br />vehicle exhaust,etc. <br />2.Splicing of flexible duct will not be allowed. <br />3.Flexible ducts shall not pass through any partition,wall,floor,or ceiling. <br />N.Duct sizes indicated are inside clear dimensions. For lined ducts,maintain sizes inside lining. <br />O.Provide openings in ductwork where required to accommodate thermometers and controllers. <br /> Provide pilot tube openings where required for testing of systems,complete with metal can with <br />spring device or screw to ensure against air leakage. Where openings are provided in insulated <br />ductwork,install insulation material inside a metal ring. <br />P.Locate ducts with sufficient space around equipment to allow normal operating and maintenance <br />activities. <br />Q.Use double nuts and lock washers on threaded rod supports. <br />R.At exterior wall louvers,seal duct to louver frame and install blank-out panels. <br />S.All trapeze hanger rods shall be cut to within 1"of the bottom nut. <br />END OF SECTION <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6
The URL can be used to link to this page
Your browser does not support the video tag.