Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Southern Human Services Center Smith Sinnett /2020072 <br />HVAC and Roof Renovations Orange County,North Carolina <br />HVAC Water Treatment 23 25 00 - 1 <br />SECTION 23 25 00 <br />HVAC WATER TREATMENT <br />PART 1 GENERAL <br />1.01 SECTION INCLUDES <br />A.Materials. <br />1.System cleaner. <br />2.Closed system treatment (water). <br />B.By-pass (pot)feeder. <br />1.02 SUBMITTALS <br />A.Product Data: Provide chemical treatment materials,chemicals,and equipment including <br />electrical characteristics and connection requirements. <br />B.Shop Drawings: Indicate system schematic,equipment locations,and controls schematics, <br />electrical characteristics and connection requirements. <br />C.Submit directly to Owner,Material Safety Data Sheets (MSDS)for all chemicals used in chemical <br />treatment systems.Include with MSDS written notice of Owner's responsibilty to notify its <br />employees of the use of those chemicals. <br />D.Certificate: Submit certificate of compliance from Authority Having Jurisdiction indicating approval <br />of chemicals and their proposed disposal. <br />E.Operation and Maintenance Data: Include data on chemical feed pumps,agitators,and other <br />equipment including spare parts lists,procedures,and treatment programs. Include step by step <br />instructions on test procedures including target concentrations. <br />F.Maintenance Materials: Furnish the following for Owner's use in maintenance of project. <br />1.See Section 01 60 00 -Product Requirements,for additional provisions. <br />1.03 QUALITY ASSURANCE <br />A.Manufacturer Qualifications: Company specializing in manufacturing the type of products specified <br />in this section,with minimum ten years of documented experience. Company shall have local <br />representatives with water analysis laboratories and full time service personnel. <br />1.04 WATER ANALYSIS <br />A.Take samples and provide analysis prior to start of work.Include existing conditions in submittal. <br />B.At completion of project,submit complete water analysis and results of performance test of each <br />system signed by manufacturer's service representative. <br />C.Water analysis shall include the following: <br />1.Hot Water and Chilled Water <br />a.Hardness <br />b.pH <br />c."M"alkalinity <br />d.Inhibitor level <br />e.Total dissolved solids <br />f.Temperature <br />1.05 WATER QUALITY REQUIREMENTS <br />A.Minimum water quality requirements for closed hot and/or chilled water systems shall be as <br />follows: <br />1.pH 8.0-9.0 <br />2.TDS <500 ppm <br />3.Hardness as CaCO3 and Alkalinity <120 ppm <br />4.Chlorides <200 ppm <br />5.Suplhates <200 ppm <br />6.Iron <0.5 ppm <br />7.Dissolved Oxygen <0.1 ppm <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6