Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Southern Human Services Center Smith Sinnett /2020072 <br />HVAC and Roof Renovations Orange County,North Carolina <br />BAS Control Valves 23 09 13.33 - 1 <br />SECTION 23 09 13.33 <br />BAS CONTROL VALVES <br />PART 1 GENERAL <br />1.01 REFERENCES <br />A.Refer to Section 23 09 00 -References <br />1.02 ACRONYMS,ABBREVIATIONS AND DEFINITIONS <br />A.Refer to Section 23 09 00 -Acronyms,Abbreviations and Definitions <br />PART 2 PRODUCT <br />2.01 VALVES <br />A.Acceptable Manufacturers: <br />1.Belimo <br />2.Bell &Gossett <br />3.Danfoss <br />4.Griswold <br />5.Siemens <br />6.Or Approved Equal <br />B.Ball-style body automatic control valves shall adhere to the following: <br />1.NPS 4 and Smaller:Nickel-plated forged brass body rated at no less than 400 psi,stainless <br />steel ball and blowout proof stem,NPT female end fittings,with a dual EPDM O-ring packing <br />design,fiberglass reinforced Teflon seats,and a Tefzel flow characterizing disc. <br />2.Sizing: <br />a.Two-Position:Line size or size using a pressure differential of 1 psi. <br />b.2-way Modulating:5 psig or twice the load pressure drop,whichever is greater. <br />c.3-way Modulating:Twice the load pressure drop,but not more than 5 psig. <br />3.Close-off Pressure Rating:100 psi.[NPS 3/4”and Smaller for Terminal Units:200 psi.] <br />4.The actuator shall be the same manufacturer as the valve,integrally mounted to the valve at <br />the factory with a single screw on a four-way DIN mounting-base. <br />5.All control ball valves shall feature characterized flow guides when used for modulating <br />applications. <br />PART 3 EXECUTION <br />3.01 APPLICATIONS <br />A.Hydronic control valves 6"and smaller shall be ball-style. <br />B.All VAV and other terminal unit control valve actuators shall be fully modulating and controlled by <br />0-10V or 4-20mA analog signal.Using floating type actuators with dual digital output for control will <br />NOT be acceptable. <br />3.02 CO-ORDINATION <br />A.Coordinate delivery of control valves to site. <br />B.Clearly tag and mark valves for their purpose and location. <br />C.Supervise Mechanical Contractor in the installation of the control valves ensuring proper valve(s) <br />are located and installed in proper location(s) <br />END OF SECTION <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6