Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Southern Human Services Center Smith Sinnett /2020072 <br />HVAC and Roof Renovations Orange County,North Carolina <br />Duct Insulation 23 07 13 - 2 <br />B.Protect insulation from weather and construction traffic,dirt,water,chemical,and mechanical <br />damage,by storing in original wrapping. <br />1.06 FIELD CONDITIONS <br />A.Maintain ambient temperatures and conditions required by manufacturers of adhesives,mastics, <br />and insulation cements. <br />B.Maintain temperature during and after installation for minimum period of 24 hours. <br />C.Insulation shall not be installed until all testing and inspection of pipe,duct,vessel,etc.has been <br />completed and approved by Engineer/Owner’s representative. <br />PART 2 PRODUCTS <br />2.01 REGULATORY REQUIREMENTS <br />A.Surface Burning Characteristics: Flame spread index/Smoke developed index of 25/50,maximum, <br />when tested in accordance with ASTM E84,UL 723,ASTM E84,or UL 723.These ratings must be <br />as tested on composite of insulation,jacket or facing,and adhesive.Components such as <br />adhesives,mastics,and cements must meet the same individual ratings as minimum <br />requirements. <br />2.02 GLASS FIBER,FLEXIBLE <br />A.Manufacturer: <br />1.CertainTeed Corporation: <br />2.Johns Manville <br />3.Knauf Insulation <br />4.Owens Corning Corporation <br />5.Or Approved Equal <br />B.Insulation: ASTM C553;flexible,noncombustible blanket. <br />1.K value: 0.36 at 75 degrees F,when tested in accordance with ASTM C518. <br />2.Maximum Service Temperature: 250 degrees F. <br />3.Maximum Water Vapor Absorption: 5.0 percent by weight. <br />C.Vapor Barrier Jacket: <br />1.Kraft paper with glass fiber yarn and bonded to aluminized film. <br />2.Moisture Vapor Permeability: 0.02 perm inch,when tested in accordance with ASTM <br />E96/E96M. <br />3.Secure with pressure sensitive tape. <br />D.Vapor Barrier Tape: <br />1.Kraft paper reinforced with glass fiber yarn and bonded to aluminized film,with pressure <br />sensitive rubber based adhesive. <br />E.Indoor Vapor Barrier Mastic: <br />1.Manufacturers: <br />a.Design Polymerics;DP 3040 Water Based,Zero VOC,Premium Quality,Low Perm, <br />Vapor Barrier Coating <br />b.Childers CP-35 <br />c.Hardcast Seal-Tack AF <br />F.Tie Wire: Annealed steel,16 gage,0.0508 inch diameter. <br />2.03 GLASS FIBER,RIGID <br />A.Manufacturer: <br />1.CertainTeed Corporation <br />2.Johns Manville <br />3.Knauf Insulation <br />4.Owens Corning Corporation <br />5.Or Approved Equal <br />B.Insulation: ASTM C612;rigid,noncombustible blanket. <br />1.K Value: 0.24 at 75 degrees F,when tested in accordance with ASTM C518. <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6
The URL can be used to link to this page
Your browser does not support the video tag.