Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Southern Human Services Center Smith Sinnett /2020072 <br />HVAC and Roof Renovations Orange County,North Carolina <br />Sleeves and Sleeve Seals for HVAC Piping <br /> 23 05 17 - 2 <br />1.Synthetic rubber interlocking links continuously fill annular space between pipe and <br />wall/casing opening. <br />2.Provide watertight seal between pipe and wall/casing opening. <br />3.Elastomer element size and material in accordance with manufacturer's recommendations. <br />4.Glass reinforced plastic pressure end plates. <br />PART 3 EXECUTION <br />3.01 INSTALLATION <br />A.Route piping in orderly manner,plumb and parallel to building structure. Maintain gradient. <br />B.Install piping to conserve building space,to not interfere with use of space and other work. <br />C.Install piping and pipe sleeves to allow for expansion and contraction without stressing pipe,joints, <br />or connected equipment. <br />D.Structural Considerations: <br />1.Do not penetrate building structural members unless approved by the Structural Engineer. <br />E.Provide sleeves when penetrating ​floors and walls​. Seal pipe including sleeve penetrations to <br />achieve fire resistance equivalent to fire separation required. <br />1.Aboveground Piping: <br />a.Pack solid using mineral fiber in compliance with ASTM C592. <br />b.Fill space with an elastomer caulk to a depth of 0.50 inch where penetrations occur <br />between conditioned and unconditioned spaces. <br />F.Manufactured Sleeve-Seal Systems: <br />1.Install manufactured sleeve-seal systems in sleeves located in grade slabs and exterior <br />concrete walls at piping entrances into building. <br />2.Provide sealing elements of the size,quantity,and type required for the piping and sleeve <br />inner diameter or penetration diameter. <br />3.Locate piping in center of sleeve or penetration. <br />4.Install field assembled sleeve-seal system components in annular space between sleeve and <br />piping. <br />5.Tighten bolting for a water-tight seal. <br />6.Install in accordance with manufacturer's recommendations. <br />G.When installing more than one piping system material,ensure system components are compatible <br />and joined to ensure the integrity of the system. Provide necessary joining fittings. Ensure <br />flanges,union,and couplings for servicing are consistently provided. <br />3.02 CLEANING <br />A.Upon completion of work,clean all parts of the installation. <br />B.Clean equipment,pipes,valves,and fittings of grease,metal cuttings,and sludge that may have <br />accumulated from the installation and testing of the system. <br />END OF SECTION <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6
The URL can be used to link to this page