Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHSC HVAC and Roof Replacement Smith Sinnett / 2020072 <br />Orange County, North Carolina <br /> <br />SHEET METAL FLASHING AND TRIM 07 62 00 - 5 <br />B. Downspouts: Fabricate rectangular downspouts complete with mitered elbows. Furnish with metal <br />hangers, from same material as downspouts, and anchors. <br />1. Fabricated Hanger Style: SMACNA figure designation 1-35C <br />2. Fabricate from the following materials: <br />a. Aluminum-Zinc Alloy-Coated Steel Sheet, 22 gauge <br />b. Exterior Finish: Fluoropolymer two-coat system. <br />c. Color: As selected by Architect from manufacturer's standard colors. <br />d. Size: 3” x 4” <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />A. Examine substrates and conditions under which sheet metal flashing and trim are to be installed and <br />verify that Work may properly commence. Do not proceed with installation until unsatisfactory <br />conditions have been corrected. <br />3.2 INSTALLATION <br />A. General: Unless otherwise indicated, install sheet metal flashing and trim to comply with performance <br />requirements, manufacturer's installation instructions, and SMACNA's "Architectural Sheet Metal <br />Manual." Anchor units of Work securely in place by methods indicated, providing for thermal expansion <br />of metal units; conceal fasteners where possible, and set units true to line and level as indicated. Install <br />Work with laps, joints, and seams that will be permanently watertight and weatherproof. <br />B. Install exposed sheet metal Work that is without excessive oil canning, buckling, and tool marks and <br />that is true to line and levels indicated, with exposed edges folded back to form hems. Install sheet metal <br />flashing and trim to fit substrates and to result in waterproof and weather-resistant performance. Verify <br />shapes and dimensions of surfaces to be covered before fabricating sheet metal. <br />C. Roof Edge and Parapet Cap Flashings: Secure flashing sat roof edges according to meet all wind load <br />conditions. All roof edge and parapet cap flashing corners shall welded, mitered and ground smooth prior <br />to finishing. <br />D. Expansion Provisions: In gutters, space expansion joints as indicated, or if not indicated place as <br />required to provide for two downspouts to be located in any gutter run between expansion joints, with no <br />joints allowed within 24 inches of corners. Fabricate expansion joints in gutters with end caps on both <br />gutter runs, separate gutter runs by 1", cover face of joint with a six inch exposed joint cover, and cap the <br />joint with an exposed cover plate. <br />1. Lapped or bayonet-type expansion joints are not permitted. <br />E. Sealed Joints: Form nonexpansion, but movable, joints in metal to accommodate elastomeric sealant to <br />comply with SMACNA standards and as follows: <br />1. Fabricate sealed joints in prefinished sheet metal with butt joints and concealed splice plates. <br />Install silicone elastomeric sealant between exposed metal work and splice plates, and rivet one <br />side of fabricated unit to splice plate for strength. <br />a. Do not use lapped or bayonet-type (nested) joints for sheet metal fabrications. <br />2. Fabricate concealed splice plates of specific size and profile to maintain lines and form of <br />fabricated work. <br />3. Provide a 1/8" gap between fabricated units at butt joints. <br />F. Separations: Separate metal from non-compatible metal or corrosive substrates by coating concealed <br />surfaces, at locations of contact, with asphalt mastic or other permanent separation as recommended by <br />manufacturer. <br />G. Install reglets to receive counterflashing according to the following requirements: <br />1. Where reglets are shown in masonry, furnish reglets for installation under Division 4 Section <br />"Unit Masonry." <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6
The URL can be used to link to this page
Your browser does not support the video tag.