Browse
Search
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
OrangeCountyNC
>
Board of County Commissioners
>
Contracts and Agreements
>
General Contracts and Agreements
>
2020's
>
2021
>
2021-414-E-AMS-Riggs-Harrod Builders, Inc-SHSC Roof & HVAC Replacement
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/3/2021 3:29:08 PM
Creation date
8/3/2021 3:22:07 PM
Metadata
Fields
Template:
Contract
Date
6/24/2021
Contract Starting Date
6/25/2021
Contract Ending Date
7/28/2021
Contract Document Type
Contract
Amount
$1,348,479.00
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHSC HVAC and Roof Replacement Smith Sinnett / 2020072 <br />Orange County, North Carolina <br /> <br /> <br />THERMAL INSULATION 07 21 00 - 5 <br /> <br /> <br />3.5 INSULATION SCHEDULE <br /> <br />Location Description Product/ Minimum Thickness R-Value Remarks <br />Top of Wall cavity insulation Unfaced Batt Insulation <br /> <br />6” Fiberglass Batts <br /> <br />R-19 <br /> <br />Provide at all cavity openings in the top of the exterior walls after installation of the new roofing system. Refer to drawings for notes and loca-tions in section details. <br /> <br />Existing Concrete Roof Deck: Refer to drawings for loca-tions. <br />TPO Roof Membrane over Polyisocyanurate Board In-sulation on Existing Con-crete Decking <br />Provide Minimum thickness of insulation to achieve the slope of the roof as designated on the roof plan with specified elevations <br /> <br />R-6 per inch minimum (2.6” mini-mum base layer) <br />Provide fully adhered TPO roofing membrane over insu-lation and fully adhered with low rise foam adhesive to the existing concrete decking. Provide adhesive in compli-ance with Manufacturer’s instructions to meet wind loads <br />Existing Metal Roof Deck: Refer to drawings for loca-tions. <br /> <br /> <br />TPO Roof Membrane over Polyisocyanurate Board In-sulation over 5/8” Type X Gypsum Board on Existing Metal Roof Deck. <br />Provide Minimum thickness of insulation to achieve the slope of the roof as designated on the roof plan with specified elevations <br /> <br />R-6 per inch minimum. (2.6” mini-mum base layer) <br />Provide fully adhered TPO roofing membrane over insu-lation and fully adhered with low rise foam adhesive to new 5/8” type x gypsum board which shall be mechan-ical fastened (per the speci-fied wind speeds) to existing metal decking. Provide fas-teners and adhesive in com-pliance with Manufacturer’s instructions to meet wind loads <br /> <br /> <br />END OF SECTION 07 21 00 <br /> <br /> <br /> <br />DocuSign Envelope ID: 94E7997D-4F29-42F6-A9B4-0A160438D2A6
The URL can be used to link to this page
Your browser does not support the video tag.