Orange County NC Website
VESTIBULE200WAITINGAREA201CORRIDOR(WEST)202OFFICE203OFFICE204OFFICE205OFFICE207OFFICE209OFFICE210OFFICE211OFFICE212OFFICE213BREAKROOM214OFFICE215RESTROOM217VESTIBULE218OFFICE219OFFICE220IT221RESTROOM222OFFICE224VESTIBULE225STAIRS226MECHANICAL227STORAGE209AA4-014A4-01567NEW COMMERCIAL GRADE OUTDOOR WHEELCHAIR LIFT. PROVIDE SUPPORT STEEL(PAINTED) SUPPORT POSTS FOR GATE AT LANDING. GATE ASSEMBLY SHALL MEET CODE REQUIREMENTS RAILING LOADING. ENSURE NO GAPS LARGER THAN 3 1/2" AT ANY POINT WHERE MEETS ENTRY POINT OF LIFT. NEW WATER COOLER SEE PLUMBINGNEW CASED OPENINGALTERNATE 1: REPLACE CASEWORKCORRIDOREAST216WAITING223CLOSET228CORRIDORCENTRAL 12088' - 6"CLEAR4' - 6"9' - 1 1/4"3 5/8"8' - 7 1/8"S4PAS4PA4' - 0"3 5/8"4' - 0"NEW TOILET, LAVATORY AND ACCESSORIESNEW TOILETS, PARTITIONS, LAVATORY AND ACCESSORIES217222215214213A213212211205204207229203229A209210225226224220219218221228200A208NO WORK IN THIS AREAOFFICE229A4-011A4-018A4-019211AREFREFEXISTING CASEWORK TO REMAINEXISTING CASEWORK TO REMAINFURNITURE BY OWNEREXISTING CASEWORK TO REMAINREPAINT EXISTING BIFOLDING DOORS1NOTES:1. WALL DIMENSIONS ARE TO FACE OF METAL STUD, DOORS NOT DIMENSIONED ARE TYPICALLY 4" FROM INTERSECTING WALL.2. ALL METAL STUD WALLS TERMINATING AT BOTTOM OF DECK ARE TO PROVIDE A DEFLECTION TRACK SECURED TO THE UNDERSIDE OF THE DECKING, NEST TOP TRACK BUT DO NOT ATTACH TO DEFLECTION TRACK. FILL FLUTE IN METAL DECK WHERE REQUIRED.3. ALL WALLS WHICH EXTEND TO DECK AND ARE BRACED TO DECK AT HEAD ON ALTERNATE STUDS, UNLESS OTHERWISE NOTED.4. SEE FINISH PLAN FOR WALL, FLOOR, BASE, AND CEILING TYPES AND FINISHES.5. FURNITURE AND EQUIPMENT SHOWN DASHED ON PLANS IS NOT IN CONTRACT (NIC). GC TO PROVIDE WOOD BLOCKING FOR ALL WALL/CEILING MOUNTED ACCESSORIES.6. FIELD VERIFY FINAL ROOM DIMENSIONS PRIOR TO CASEWORK FABRICATION.MARKERSYMBOLDESCRIPTIONWALL TYPE LEGENDS4PA3 5/8" METAL STUD WITH BATT INSULATION AND TWO LAYERS 5/8" GYP BOARD EACH SIDE UP TO MIN. 8" ABOVE CEILING5/8" GYPSUM WALL BOARD EACH SIDEBATT INSULATIONCEILING -REFER TO CEILING PLANS FOR TYPE8"EXISTING HARD CEILINGT 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comDRAWN BY:CHECKED BY:DESCRIPTIONDATEIDThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETC:\Users\drew.SSA\Documents\2020048_OC Court Street Annex_dwilgus@smithsinnett.com.rvt1/23/2021 2:12:07 AMA1-01FLOOR PLAN2020048 14 Dec. 2020CONSTRUCTION DOCUMENTSMADWORANGE COUNTY, NC FACILITY RENOVATIONSCOURT STREET ANNEX - RENOVATION109 Court Street, Hillsborough NCREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT1/4" = 1'-0"A1-011FLOOR PLAN1 1/22/2021 ADDENDUM 31 1/22/2021 ADDENDUM 3DocuSign Envelope ID: 09980A3B-0691-41B4-854D-3865F2287392