VESTIBULE200WAITINGAREA201CORRIDOR(WEST)202OFFICE203OFFICE204OFFICE205OFFICE207OFFICE209OFFICE210OFFICE211OFFICE212OFFICE213BREAKROOM214OFFICE215RESTROOM217VESTIBULE218OFFICE219OFFICE220IT221RESTROOM222OFFICE224VESTIBULE225STAIRS226MECHANICAL227STORAGE209ACORRIDOREAST216WAITING223CLOSET228CORRIDORCENTRAL 1208OFFICE229910910910910910910910910910910NO WORK IN THIS AREA9109109109109109109109108108108108109' -0"D7' -10"D7' -10"9' -0"9' -0"9' -0"9' -0"9' -0"9' -0"D7' -6"9' -0"9' -0"D8' -0"D8' -0"8' -0"CORRIDOR(WEST)202D9' -0"D8' -0"D7' -6"D7' -10"9' -8"9' -8"9' -7"D8' -0"8' -0"9' -7"9' -8"9' -8"D8' -0"D8' -1"D8' -3"D8' -0"D8' -0"D8' -0"D8' -0"D8' -0"D8' -0"D8' -0"11810D8' -0"D8' -0"DEMOLITION SPECIFIC AREA NOTES:1REMOVE EXISTING BASE, CARPET, VCT, CERAMIC TILE (RESTROOMS) AND/OR ANY OTHER FLOOR FINISH. PREPARE FLOORING TO RECEIVE NEW FINISHES PER SPECIFICATION AND THESE CONSTRUCTION DRAWINGS.234689REMOVE EXISTING WALL, FRAMING, AND ASSOCIATED PARTS IN ITS ENTIRETY. ASSOCIATED PARTS INCLUDE BUT NOT LIMITED TO DOOR, DOOR FRAME, HARDWARE, TRACK AND SUPPORTS. PREPARE SURROUNDING AREA TO RECEIVE NEW FINISH SPECIFIED OR IF NO FINISH IS SPECIFIED MATCH EXISTING. REMOVE EXISTING GYPSUM WALL TO THE EXTENTS SHOWN. REMOVE EXISTING PEELING PAINT. CONTRACTOR SHALL PREP EXISTING SURFACES AS NECESSARY TO ENSURE THE MAXIMUM ADHESION BETWEEN THE EXISTING SURFACES AND NEW PAINT.REMOVE EXISTING LAY-IN CEILING TILE, GRID, HANGERS AND ASSOCIATED PARTS IN ITS ENTIRETY. PREP AREA TO RECEIVE NEW CEILING.PREP AREA TO RECEIVE NEW CEILING. EXISTING HARD CEILING TO REMAIN, WITH NEW LAY-IN CEILING INSTALLED BELOW PER A1-20. CEILING AND FIXTURE HANGERS ARE TO BE PROPERLY SECURED AND FASTENED TO ORIGINAL CEILING FRAMINGREMOVE EXISTING LIGHT FIXTURES AND REPLACE WITH NEW LIGHT FIXTURES WITHIN NEW CEILING GRID. REFER TO ELECTRICAL DRAWINGS FOR COMPLETE SCOPE OF DEMOLITION. REFER TO GENERAL DEMO NOTES FOR REQUIREMENTS ON BULB AND BALLAST DISPOSAL.10REMOVE EXISTING CASEWORK, BASE CABINET, SHELF, OR WALL HUNG COUNTER. PATCH AND REPAIR ADJACENT SURFACES AS REQUIRED. 11REMOVE EXISTING PLUMBING FIXTURE, SINK, OR WATER COOLER IN ITS ENTIRETY. PATCH AND FILL VOID IN EXISTING FROM FASTENERS OR PIPING. REFER TO PLUMBING FOR COMPLETE SCOPE OF PLUMBING DEMOLITION. ITEM SHALL BE OFFERED TO THE OWNER AND STORED IN AN APPROVED LOCATION DESIGNATED BY THE OWNER. IF THE OWNER DECLINES, THE CONTRACTOR SHALL DISPOSE OF THE ITEM.REMOVE EXISTING WOOD PANELING, FURRING, NAILS AND ITS ASSOCIATED PARTS IN ITS ENTIRETY BACK TO THE EXISTING CMU WALLS. PREP WALLS TO RECEIVE NEW PAINT FINISH. REMOVE ANY ASSOCIATED FASTENERS AND PATCH WALL.125BASE BID: DOOR TO RECEIVE NEW HARDWAREALTERNATE 2: REMOVE EXISTING DOOR. REPLACE WITH NEW DOOR LEAF AND HARDWARE, EXISTING FRAME TO REMAINREMOVE EXISITNG DOOR AND WOOD FRAME TO CREATE CASED OPENING WITH NEW FINISHED GYPSUM BOARD.7REMOVE EXISTING WALL PAPER AND PREP WALL FOR NEW PAINT13REMOVE PEG BOARD PANEL AND PREP WALL FOR NEW PAINT14GENERAL DEMOLITION NOTES:1. ALL CONDITIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR WHERE DEMOLITION IS TO OCCUR. THE CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY INCONSISTANCIES IN WRITING PRIOR TO STARTING ANY WORK.2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR WEEKLY AND/OR DAILY REMOVAL AND PROPER DISPOSAL OF ALL DEBRIS ACCUMULATED DURING DEMOLITION AND CONSTRUCTION.3. ANY FLOOR, CEILING, WALL OR OTHER MATERIALS INCLUDING FINISHES IN AREAS TO REMAIN ARE THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT. ANY MATERIALS DAMAGED DURING CONSTRUCTION OR DEMOLITION, SHALL BE RETURNED TO THEIR ORIGINAL STATE, OR IMPROVED AS INDICATED BY THE OWNER OR ARCHITECT, OR REPLACED WITH A NEW MATERIAL TO MATCH ADJACENT MATERIALS, TYPICAL. 4. CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING SURFACES TO REMAIN AND MATERIALS EXPOSED TO VIEW WHERE OTHER ITEMS OR MATERIALS HAVE BEEN REMOVED.5. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL AND COMPLETE SCOPE OF DEMOLITION THAT MAY OR MAY NOT BE NOTED ON THE ARCHITECTURAL DEMOLITION PLAN AND NOTES.6. CONTRACTOR SHALL REMOVE ALL WALL MOUNTED FIXTURES OR ITEMS WITHIN THE SCOPE OF DEMOLITION UNLESS OTHERWISE NOTED. ALL WALLS SHALL BE REPAIRED, AND VOIDS FILLED AFTER FIXTURE REMOVAL. ALL FINISHES SHALL MATCH ADJACENT SURFACES. REMOVE ALL FOREIGN MATTER, SHELVING, LOOSE DEBRIS INCLUDING TAPE, ADHESIVE, NAILS, SCREWS, ETC. FROM WALLS. SCRAPE, WIRE BRUSH, AND SAND SMOOTH. WASH ALL PAINTED SURFACES TO REMOVE ANY "FILM OR RESIDUE". PREPARE SURFACES TO PROVIDE A MAXIMUM DEGREE OF NEW PAINT ADHESION. PATCH AND REPAIR ALL VOIDS IN PREPARATION FOR NEW FINISHES.7. ALL FIXTURES, WALLS AND PORTIONS OF WALLS SHOWN AS DASHED LINES OR LABELED SHALL BE DEMOLISHED UNLESS ELEMENTS REMOVED OR REPLACED. CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING AND IS RESPONSIBLE FOR ANY FAILURE DUE TO LACK OF PROPER BRACING.8. DURING THE BIDDING PROCESS, CONTRACTORS SHALL TAKE NOTE OF EXISTING PLUMBING MECHANICAL, AND ELECTRICAL ITEMS IN AREAS TO BE RENOVATED. ITEMS INCLUDE BUT ARE NOT LIMITED TO WIRES, CONDUITS, PIPES, THERMOSTATS, FIRE ALARM DEVICES, PANEL CANS, ETC. THESE HAVE BEEN IDENTIFIED IN THE DEMOLITION DRAWINGS FOR ARCHITETURE, PLUMBING, MECHANICAL, AND/OR ELECTRICAL. FOR ITEMS NOT SHOWN, CONTRACTOR SHALL WORK WITH THE ARCHITECT AND OWNER TO DETERMINE IF THE ITEM IS STILL IN USE ITEMS WHICH ARE NOTED TO BE REMOVED AND STORED FOR LATER REINSTALLATION SHALL BE TAGGED AND LISTED ON AN ITEMIZED LIST GIVEN TO THE OWNER AND ARCHITECT.9. THE GENERAL CONTRACTOR SHALL COORDINATE THE DEMOLITION OF THE EXISTING BUILDING AREAS WITH THE ARCHITECT AND OWNER. THE CONTRACTOR SHALL COORDINATE AFTER HOURS WORK AND OBTAIN WRITTEN OWNER PERMISSION FOR NIGHT AND WEEKEND WORK.10. ALL EXISTING FIRE EXTINGUISHER AND BRACKETS SHALL REMAIN AND BE INSTALLED IN THEIR CURRENT LOCATION UNLESS SHOWN ON THE PLANS TO RELOCATE.11. CONTRACTOR SHALL PATCH AND FILL IN ANY VOIDS LEFT FROM THE DEMOLITION OF ANY PLUMBING, MECHANICAL, OR ELECTRICAL ITEMS. REFER TO PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS FOR COMPLETE SCOPE OF DEMOLITION.DEMOLITION LEGEND:DEMOLITION KEYED NOTEDESCRIPTIONSYMBOLEXISTING TO REMAINEXISTING TO BE REMOVED DURING DEMOLITION#EXISTING CONDITION PHOTOS#PHOTO LOCATIONT 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comDRAWN BY:CHECKED BY:DESCRIPTIONDATEIDThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETC:\Users\drew.SSA\Documents\2020048_OC Court Street Annex_dwilgus@smithsinnett.com.rvt1/23/2021 2:12:06 AMA0-20DEMO REFLECTEDCEILING PLAN2020048 14 Dec. 2020CONSTRUCTION DOCUMENTSMADWORANGE COUNTY, NC FACILITY RENOVATIONSCOURT STREET ANNEX - RENOVATION109 Court Street, Hillsborough NCREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT1/4" = 1'-0"A0-201DEMO CEILING PLANALTERNATE 11 1/22/2021 ADDENDUM 31 1/22/2021 ADDENDUM 31REMOVE WOOD VALENCE ABOVE WINDOWS1DocuSign Envelope ID: 09980A3B-0691-41B4-854D-3865F2287392
|